Pump with magnetic drive
41.008.100  - AK MULLER FRANCE

Description

This pump is designed to increase pressure to enable a higher flow rate and improved dispense accuracy. It is ideal for applications where a low water level in a boiler causes an insufficient flow rate through traditional boiler dispense valves. Use of the pump allows for flexible positioning of dispense valves inside the machine, including up to 1 metre above the water level in the boiler. This is particularly useful in applications such as table top vending machines where space is limited. When a dispense valve bank is used with the pump, the bank can be fitted with a re-circulating bypass which allows water to be fed back into the boiler. This helps maintain a constant water temperature within the system. Varying the voltage supplied to the pump will change its speed and thus vary the flow rate output. The impeller is driven by a non-contact magnetic connection which avoids the use of additional seals preventing potential leak paths. The pumps body housing is suitable for use...

Product features

Motor support PA 66
Pump housing PSU
Impeller PA 6/6
Pump shaft Stainless steel
Bearing ruby washer and bush bearing
Seal (motor support) EPDM
Seal (outlet nozzle) VMQ
Magnetic clutch of impeller hard ferrite, 4-pole magnetised
Type pump
Construction Construction The term construction here is normally referred to the design of a val centrifugal pump
mode of operation not self priming
Fitting position any, preferably with motor upwards
Media Cold and heated potable water and physically and chemically similar media
T-Medium 98 °C max.
T-Ambient 70 °C (158 °F) max.
DN DN Numerical size indication of the nominal free diameter (diameter nominal) of components fo 8 mm (0.315 inch)
p-max (24 VDC) 155 mbar
Motor type direct current motor
Nominal voltage Nominal voltage Voltage for which the valve is designed. A fluctuation range fro 24 V DC
Voltage range 16-28 V DC
Duty cycle Duty cycle Indicated as ED on equipment nameplates. It refers to the percentage opera 100%
Protection type Protection type Standard which defines the scope of protection of the electromag IP 00 according to EN 60529
Motor connections soldering lug 4,8 x 0,5 mm
Basic interference suppression 2 x 10nF ceramic capacitors X7R 100V
Insulation class B according to EN 60730
Protection Class III according to EN 60730