The high-precision calibration laboratory is accredited according to DIN EN ISO/IEC 17025 for flow calibration of flowing gases. The EP calibration laboratory is accredited by the DAkkS according to DIN EN ISO/IEC 17025:2005 for calibrations of gases in-house and on-site under the procedure number D-K-21444-01-00. We offer calibrations for gas flow measurement as well as temperature, humidity and pressure measurements. In addition, we calibrate all measured variables of the test bench directly at your site. Our experienced technicians also check the harmonious interaction of all sensors, so that the entire system is perfectly tuned. The opening of our new calibration laboratory in Asia enables us to offer you even better service internationally.
Germany
This Hygrostick 8703 is a robust, portable hygrometer for temperature, air humidity and dew point measurement. LESS THAN HALF PRICE !!
Request for a quoteGermany
The precision Pt100 simulator is used wherever measuring instruments or controlling systems have to be tested or calibrated with great precision. The standard version model 4506 simulates 24 set temperature values. Totally different temperature ranges are required in the case of special applications, such as in the food industry, the medical science etc. Model 4506 S is recommended for these applications and can be fitted with 24 temperature values according to customer specifications. A distinctive feature of these simulators is their simple operation. The resistance values required for simulation are directly set in °C. There is no need to use loof-up tables. Today in many cases a certificate is needed more than ever force measurements. This certificate is available under order code 45DKD-.. . Features: 24 set temperature values Calibration per DIN EN 60751 Resistor material: MANGANIN®, TK ≤ 10 ppm/K Pt100, Pt500, Pt1000 Available with DKD Certificate if required
Request for a quoteGermany
High-precision angle measuring system with +/-0.1s accuracy for measuring and calibration applications. The signal sampling is done by an interferometric operating principle (laserscale) The graduation period is 1µm, the generated signal period of the output signal is 250nm. Scale errors are self-compensated by using six reading heads in a special arrangement. The measured values can be output in csv format via the USB interface. The software for measured value acquisition and storage is included in the scope of delivery.
Request for a quoteGermany
Essential for direct reading and high-capacity torque wrench calibration! Mechanical loaders increase the accuracy ot torque test results while simultaneously reducing technician fatigue from pulling or pushing on torque wrenches during testing. A mechanical loader is the perfect accessory to increase the repeatability and productivity of the System 5 Digital Torque Tester. The drive system for each loader assures true 90-degree force application to eliminate force angle error in testing. In addition, the loaders mechanical advantage reduces technician effort and fatigue, particularly in high-capacity tool testing. SR Mechanical Loaders use the highest quality ball screws to assure smooth operation and extended service life. Welded steel frames and rigid transducer mounting plates assure torque load is properly resisted. Optimized gearing selection reduces physical effort to operate, enhancing productivity and ergonomic safety.
Request for a quoteCreate one request and get multiple quotes form verified suppliers.