France
Manufacturer/ Producer
France
Suitable for large flow rates with low permanent pressure dropSolder (BW) or flanged connection Material: Standard: carbon steel, stainless steel, others according to your application. Fluid: liquid, gas, steam. Diameter of pipes: from 65 to 500 mm.
Request for a quoteFrance
The sonic state of the nozzle means that the flow reaches the speed of sound when going through the throat. Under these conditions, the flow rate depends mainly on the upstream pressure and the fluid temperature. This makes it possible to deliver a stable and perfectly known flow, independent of the downstream pressure conditions of the nozzle. This nozzle is thus used to provide a standard flow value when it comes to calibrating another type of flow meter.
Request for a quoteFrance
The venturi tube has a convergent inlet, a throat and a divergent outlet. It is a differential pressure flow meter well known to create a low permanent pressure drop; thus, it is suitable for measuring, for example, a low pressure flow rate. More over, it requires short upstream and downstream straight lengths. There are different types of venturi tubes : the machined venturi made from a solid round for small size parts, the rolled welded venturi made from sheet metal for larger pieces up to 1200 mm diameter and the venturi "as cast" allowing a better accuracy up to 800 mm diameter.
Request for a quoteFrance
Suitable for large diameters and / or low permanent pressure dropMaterial: Standard: carbon steel, stainless steel, others according to your application.
Request for a quoteFrance
Suitable for small diameters and / or low permanent pressure dropMaterial: Standard: carbon steel, stainless steel, others according to your application. Fluid: liquid, gas, steam. Diameter of pipes: from 50 to 250 mm.
Request for a quoteFrance
For a better precisionSolder (BW) or flanged connection Material: Standard: carbon steel, stainless steel, others according to your application.
Request for a quoteFrance
the desired orifice (orifice plate, nozzle) the flanges to fix the orifice the pressure taps (at the flange or in the corners, depending on the primary element chosen) and the impulse tubes integrated or remote 3 or 5 way manifold the preset differential pressure transmitter the built-in temperature sensor (for temperature compensation) in option MOUNTING AND ASSEMBLY DATA: Optimized centering of the measuring element Honing of upstream and downstream pipes to meet roughness criteria Temperature and pressure compensation for gases to achieve very accurate flow measurement Remote mounting of the instrumentation according to the applications CHARACTERISTICS : For orifice plates: see corresponding technical data sheet For nozzles: see corresponding technical data sheet Straight lengths upstream, downstream, roughness and circularity of the tubes, centering measuring element: see details on the FAQ tab on this page ACCESSORIES : Temperature sensor: Sensor mounted on downstream
Request for a quoteFrance
Simple, economical and leak-free installationMounting between flanges: ISO PN 2,5 to PN 420, ASME 150 # to 2500 #, others on consultation. Material: Standard: 304L / 306L stainless steel, others according to your application.
Request for a quoteFrance
Complete measuring element with special flanges - Suitable for pipe diameters ≤ 40 mmInstallation of the integrated sharp-edge orifice plate: between special flanges (direct mounting of the manifold and the differential pressure transmitter) Solder (BW) or flanged connection Material: Standard: carbon steel, stainless steel, others according to your application.
Request for a quoteFrance
Complete and flexible measuring element to facilitate on-site installationMounting of the primary element between flanges: ISO PN 2.5 to PN 420, ASME 150 # to 2500 #, others on consultation. Solder (BW) or flanged connection Material: Standard: carbon steel, stainless steel, others according to your application.THE FLOWMETER INCLUDES: the desired orifice (orifice plate, nozzle) the flanges to fix the orifice upstream and downstream straight lengths in accordance with the chosen standard ASSEMBLY AND ASSEMBLY DATA: The design, manufacture and assembly are carried out in our workshops in compliance with the standards (upstream and downstream pipe roughness, centering of the primary element, circularity of the piping, upstream and downstream straight lengths) in order to achieve optimal measurement accuracy. CHARACTERISTICS : orifice plate - see corresponding technical data sheet nozzle - see corresponding technical data sheet upstream, downtrseam straight lengths
Request for a quoteManufacturer/ Producer
Chemin les AUGAS
Rd 817
64170 Lacq - France