The B2B sourcing platform
Add my company Log in

FLAMESTOP - Protect from fire what is important to you and your business

FLAMESTOP

Russia

Fire extinguishing agent: gas (Freon 125, Freon 227, FK-5-1-12) Gas fire extinguishing modules MGA-FS 65-HH-33 are designed for long-term storage and emergency release into the protected room of a gas fire extinguishing agent (GFEA) when extinguishing a fire by volumetric or local volumetric method. They are used as part of automatic gas fire extinguishing systems of modular or centralized type. They are used to extinguish fires of class A, B, C and electrical equipment under voltage. Placed in protected premises or outside protected premises, in close proximity to them. Volume: 40 l, 50 l, 80 l, 100 l, 120 l, 140 l. The delivery set of the modules includes: a module with a shut-off valve and a pressure gauge (starting devices are not included in the delivery set), a protective cover, an operation manual with a passport for the module, a copy of the certificate of conformity for the module, packaging. The module is sold empty or filled with gas.

Russia

Fire extinguishing agent: gas (Freon 125, Freon 227, FK-5-1-12) Gas fire extinguishing modules MGA-FS 65-HH-50 are designed for long-term storage and emergency release into the protected room of a gas fire extinguishing agent (GFEA) when extinguishing a fire by volumetric or local volumetric method. They are used as part of automatic gas fire extinguishing systems of modular or centralized type. They are used to extinguish fires of class A, B, C and electrical equipment under voltage. Placed in protected premises or outside protected premises, in close proximity to them. Volume: 40 l, 50 l, 80 l, 100 l, 120 l, 140 l. The delivery set of the modules includes: a module with a shut-off valve and a pressure gauge (starting devices are not included in the delivery set), a protective cover, an operation manual with a passport for the module, a copy of the certificate of conformity for the module, packaging. The module is sold empty or filled with gas.

Russia

Fire extinguishing agent: gas (Freon 125, Freon 227, FK-5-1-12) FS series starters - nominal diameter 32 mm and 50 mm. The devices are designed for use in gas fire extinguishing systems. They are installed on the shut-off valve and provide the release of the gas fire extinguishing agent from the gas extinguishing module. One device provides extinguishing gas in one direction. To supply extinguishing gas in two or more directions, the required number of devices is installed on the manifold of an automatic gas fire extinguishing installation. The way of starting devices is electric (using an electromagnet).

Russia

Fire extinguishing agent: gas (Freon 125, Freon 227, FK-5-1-12) The device is intended for use in gas fire extinguishing systems. They are installed on the shut-off valve and provide the release of the gas fire extinguishing agent from the gas extinguishing module. One device provides extinguishing gas in one direction. Method of starting devices - pneumatic

Russia

FIREDETEC CLS is an innovative development in the field of fire detection and extinguishing. The fire detection sensor in the engine fire extinguishing system is a flexible linear sensor tube filled with nitrogen. It can be easily installed above the engine, around it, and close to possible fire points. Due to its flexibility, the sensor tube is installed even in hard-to-reach places, which allows 100% coverage of the entire protected area. If the temperature rises to + 175 ° C at any point of the sensor tube due to a fire, the fire extinguishing system for the car instantly and automatically initiates the start of the extinguishing agent.

Russia

Fire extinguishing agent: gas (Freon 125, Freon 227, FK-5-1-12, CO2) The KSID overpressure relief valve is designed to protect premises and equipment from overpressure generated during the release of a gas fire extinguishing agent from the gas fire extinguishing modules into the room. KSID-FS is a device, the shutter of which opens when an excess gas pressure in the room is reached, corresponding to the opening pressure of the shut-off valve body, and the medium discharge is released from the protected room into the atmosphere. After the medium discharge has been released to the set pressure, the shut-off element is seated on the seat with a predetermined tightness of the valve, which ensures a longer preservation of the extinguishing concentration of the extinguishing gas in the protected room.

Russia

The ProReact Digital linear heat fire detector is designed to determine the point of fire along the entire length of the sensitive element (thermal cable). The ProReact Digital linear heat fire detector is a twisted pair thermal cable, trimetallic conductors, which are enclosed in a polymer coating with sensitivity to temperature conditions. The two conductors are twisted together in a special way to maintain mechanical tension and are enclosed in protective coating. When the temperature rises above the set value, the polymer melts, the conductors are closed and send a signal directly to the fire alarm panel or to the fire alarm panel through the interface module.

Russia

ProReact Analogue LHD is a new high-tech, universal linear thermal fire detector, which is a four-core twisted pair of copper conductors coated with a temperature-sensitive doped polymer. In response to the built-in software of the interface unit, the sensitivity of the cable is adjusted depending on factors and the ambient temperature. The range of sensitivity of the fire detector is from + 54°С to 105°С. ProReact Analogue LHD is a non-destructible thermal cable that responds to temperature changes at any point. When the temperature rises as a result of a fire, a fire signal is sent to the interface module, and if the temperature does not exceed 125°С, then the system fully restores its operability.

Russia

Interface fire module THERMOCABLE _MIP2I works in conjunction with a linear thermal fire detector. When the set temperatures are applied to a linear heat fire detector, due to overheating or a fire in any of the two zones, MIP2I automatically calculates the distance to the overheating point on the linear heat fire detector and displays the resulting value in meters. The two zones operate independently of each other, and each zone has its own alarm and a normally conducted fault output. MIP2I is designed for installation between a linear thermal fire detector and an addressable or non-addressable fire alarm control panel. MIP2I has indicators for power supply, failure and alarm indicator, which are responsible for each separate zone. Also, MIP2I can be connected to an automated production process control system using a two-wire RS-485 Modbus RTU output.

Russia

FEDETEC F / K - is an innovative development in the field of fire detection and extinguishing. The fire detection sensor in the kitchen equipment fire extinguishing system is a flexible linear sensor tube filled with nitrogen, which is installed on the exhaust hood. The sensor tube is installed over the entire area of the exhaust hood, which allows 100% coverage of the entire protected area. If the temperature rises to +175 ° C at any point of the sensor tube due to a fire, the system instantly and automatically initiates the start of the extinguishing agent. The main difference between the FIREDETEC kitchen fire extinguishing system and similar ones on the Russian market is the detection of fire at any point of the sensor tube, in contrast to thermal point locks, which are installed at a certain distance from each other and are triggered only when the fire directly affects the lock.

Office Building Outline icon
A page for your business
Can you see this? Your potential clients will too. Join us now so you too can be visible on Europages
Website