We offer you standardised complete systems for the measurement of volume & mass flows. The EP LMF®-LaminarMasterFlow® is a complete system for high-precision flow measurement of gases and air. The LMF® system consists of a flow processor, a Laminar Flow Element (LFE) as measuring section, a cable set and a sensor package. The flow measurement is performed by means of Laminar Flow Elements (LFE), which are available in different sizes and cover a measuring range from 0.01 to 700 m³/h. (optionally up to 4000 m³/h).
Germany
Essential for direct reading and high-capacity torque wrench calibration! Mechanical loaders increase the accuracy ot torque test results while simultaneously reducing technician fatigue from pulling or pushing on torque wrenches during testing. A mechanical loader is the perfect accessory to increase the repeatability and productivity of the System 5 Digital Torque Tester. The drive system for each loader assures true 90-degree force application to eliminate force angle error in testing. In addition, the loaders mechanical advantage reduces technician effort and fatigue, particularly in high-capacity tool testing. SR Mechanical Loaders use the highest quality ball screws to assure smooth operation and extended service life. Welded steel frames and rigid transducer mounting plates assure torque load is properly resisted. Optimized gearing selection reduces physical effort to operate, enhancing productivity and ergonomic safety.
Request for a quoteGermany
This high-precision calibration source is able to measure currents up to ±50 mA, voltages ±100 V and temperature setpoint values of 12 thermocouple types, including R, S, B, J, T, E, K and N. Voltage drops across the measuring leads can be easily compensated via the sense line. With “thermoelectric voltage simulation” you can enter °C, °F and K, the temperature scales ITS-90 or IPTS-68 and the reference junction type constant/external. Furthermore, when simulating thermocouples a calibrated external reference junction can be used, with the calibration data being taken into account in the device. The device can be operated both via the keypad and via the Ethernet and USB interface. Features: — DC voltage up to ±100.0000 V, ±0.002 % — DC current up to ±50.0000 mA, ±0.005 % - Thermocouple simulation of R, S, B, J, T, E, K, N, M, C, D, G2 - Automatic sequence function (ramp function)
Request for a quoteGermany
High-precision angle measuring system with +/-0.1s accuracy for measuring and calibration applications. The signal sampling is done by an interferometric operating principle (laserscale) The graduation period is 1µm, the generated signal period of the output signal is 250nm. Scale errors are self-compensated by using six reading heads in a special arrangement. The measured values can be output in csv format via the USB interface. The software for measured value acquisition and storage is included in the scope of delivery.
Request for a quoteTurkey
"FFU (Fan Filter Units) that require precise cleanliness of environmental air (as per ISO 14644 standard flow environments) also need to operate in a laminar air flow in these situations. Mikropor produces Fan Filter Units with two stage filtration. Fan Filter Units ( FFU) are based on a push and pull working principle, with environmental air drawn through a G4 class coarse filter to capture relatively large particles. Thanks to Mikropor’s highly efficient HEPA class filters on the second stage, outlet air on the production lines will have the highest level of air purity. Mikropor produces standard or custom sized Fan Filter Units, designed and manufactured to meet the cleanroom application requirements."