up to max. 2,000 mPas, with threaded connection Ideal for measuring of aggressive liquids such as acids and alkalis Liquid examples: hydrochloric acid, nitric acid, etc. Features: Measuring via nutating disc Mobile installed on a drum pump or stationary in plant construction For thin-bodied up to medium-viscous liquids Touch screen display with self-explanatory, multilingual user interface Range of measurement from 2.6 GPM - 31.7 GPM (10 l/min - 120 l/min) In plastic (PPO) Unmistakeable plug connections Benefits: Intelligible handling Precise measuring results Simple, modular construction Easy handling User-error protection Reliable operation Easy and unmistakeable assembly Volume preset: The preselected volume is filled by pressing a key. Volume preset is possible only when relay module is connected Explosion Protection: not explosion-proof PURE version: without PURE version Volume preselction: with volume preselction

Product features

Field of application Abrasive liquids like acids and alkalis
Flow rate min. 10 up to max. 100 l/min*
Temperature max. 60 °C
Range of viscosity 2,000 mPas
Operating pressure max. 4 bar
Accuracy ± 1% standard < 1% with adjustment to application conditions
Inlet port G 2 outer thread to fit connector with union nut
Outlet port G 1 1/4 outer thread
LCD display Touch-Screen 63x63 mm, 128x128 pixels, display sub-total and total volume can be reset
Menue language DE, GB, ES, FR, IT, NL, PT, RU
Materials PPO PPO/PPS FPM PPS encapsulated
Protection type IP 55
Weight 1.6 kg
Voltage 220-230 V
Frequency 50-60 Hz
Switching outputs 2 NO (potentially bound)
Output 1 (pump) 8 A, cos > 0,7
Output 2 (Valve) 0.5 A