Flow Meter TS type UN10 With Ex volume preset

Nutating Disc Meter
Web icon

Description

up to max. 2,000 mPas with threaded connection Ideal for measuring solvents and easy flammable liquids as well as acids and alkalis. Liquid examples: Methanol, gasoline, isopropanol, kerosene, formic acid, acetic acid, acetone, styrol, xylene, toluol, etc. Features: Mobile installed on a drum pump or stationary in plant construction Measuring via nutating disc For thin-bodied up to medium-viscous liquids Touch screen display with self-explanatory, multilingual user interface Range of measurement from 10 l/min up to 120 l/min In plastic (PPS) Approved according to ATEX Directive 2014/34/EU, Category 2 Benefits: Intelligible handling Precise measuring results Simple, modular construction Basis flow meter electrically conductive Simple calibration User-error protection Reliable operation Easy and unmistakeable assembly Volume preset: The preselected volume is filled by pressing a key. Volume preset is possible only when relay module is connected Explosion Protection:...

Product characteristics

Field of application
Solvents and easily infl ammable liquids, most of acids and alkalis.
Flow rate
min. 10 up to max. 100 l/min*
Temperature
max. 40 °C
Range of viscosity
2,000 mPas
Operating pressure
max. 4 bar
Accuracy
± 1% standard < 1% with adjustment to application conditions
Inlet port
G 2 outer thread to fi t connector with union nut
Outlet port
G 1 1/4 outer thread
LCD display
Touch-Screen 63x63 mm, 128x128 pixels, display sub-total and total volume can be reset
Menue language
DE, GB, ES, FR, IT, NL, PT, RU
Materials
PPS LCP FEP PPS encapsulated
Identification
II 2 G Ex ib IIB T4** II 2 G T4
Protection type
IP 55
Weight
4.3 kg
Voltage
220-230 V
Frequency
50-60 Hz
Switching outputs
2 switching outputs (potentially bound)
Output 1 (pump)
8 A, cos > 0,7
Output 2 (Valve)
0.5 A
Identification
II 2 G Ex de [ib Gb] IIC T6 Gb

Domain icon Manufacturer/ Producer

97877 Wertheim - Germany

Contact