Guided radar measurement Time-of-Flight Levelflex FMP54

Description

Levelflex FMP54 for continuous level measurement in liquids under extreme conditions. The process connection with its ceramic-graphite seal safeguards high temperature and high pressure applications as they occur in steam boilers and toxic media like ammonia. The gas tight feedthrough guarantees additional safety. Only the gas phase compensation of the FMP54 gives reliable results in case of gas and steam phases. Reliable measurement in case of moving surface and foam or in changing medias.

Product characteristics

Measuring Principle
Guided radar
Characteristic / Application
Premium device high pressure/ high temperature; Rod probe, Rope probe, Coaxial Probe; Integrated dat
Interface measurement
Clean interfaces liquid/ liquid54321; Simultaneous measurement of interface and overall level
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus); 4-wire (HART)
Accuracy
Rod probe: +/- 2 mm (0.08 in); Rope probe <= 15 m (49 ft):; +/- 2 mm (0.08 in); Rope probe > 15 m (4
Ambient temperature
-40...+80 °C; (-40...+176 °F)
Process temperature
XT: –196...+280 °C; (–321...+536 °F); HT: –196...+450 °C; (–321...+842 °F)
Process pressure absolute / max. overpressure limit
Vakuum...400 bar; (Vacuum...5800 psi)
Main wetted parts
Rod probe:; 304, 316L, Alloy C, Ceramic; Rope probe:; 304, 316, 316L, Alloy C, Ceramic; Coaxial prob
Process connection
Thread:; G 1 1/2, MNPT 1 1/2; Flange:; ASME 2"...4",; DN50...DN100,; JIS 10K, 63K,; Fisher; Masoneil

Domain icon Manufacturer/ Producer

4153 Reinach Bl - Switzerland

Contact

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free