High Precision Measuring Tube Deltatmhp

Web icon

Description

the desired orifice (orifice plate, nozzle) the flanges to fix the orifice the pressure taps (at the flange or in the corners, depending on the primary element chosen) and the impulse tubes integrated or remote 3 or 5 way manifold the preset differential pressure transmitter the built-in temperature sensor (for temperature compensation) in option MOUNTING AND ASSEMBLY DATA: Optimized centering of the measuring element Honing of upstream and downstream pipes to meet roughness criteria Temperature and pressure compensation for gases to achieve very accurate flow measurement Remote mounting of the instrumentation according to the applications CHARACTERISTICS : For orifice plates: see corresponding technical data sheet For nozzles: see corresponding technical data sheet Straight lengths upstream, downstream, roughness and circularity of the tubes, centering measuring element: see details on the FAQ tab on this page ACCESSORIES : Temperature sensor: Sensor mounted on downstream

  • Yardsticks, metersticks, tape measures and rulers
  • Measuring Tube
  • Deltatmhp Measuring

Product characteristics

Standards
ISO 5167-1 & 2, ASME MFC-3M or ISO / TR 15377
Connection
solder (BW) or flanges
Fluid
liquid, gas, steam
Overall accuracy of measurement
≤ 1% of max flow
Repeatability of the measure
0.1%

Documents

Domain icon Manufacturer/ Producer

64170 Lacq - France

Contact