Turkey
Manufacturer/ Producer
Turkey
product Origin : Kocaeli, Turkey Brand Name : Katana Generator Model Number : KD 13 D&M Rated Voltage : 230/400 V Speed : 1500RPM Frequence : 50 HZ Type :Three Phase Alternator Engine: Detroit Alternator : Megatron Control panel : Datakom
Request for a quoteTurkey
Warranty :: 3000 hours, 5 years Certificate: ISO, CE Place Of Origin: Kocaeli, Turkey Brand name: Katana Generator Model Number: KD 23 D&M Rated voltage:230/400 V Speed: 1500RPM Frequance: 50 HZ Type : AC Three Phase Engine : Detroit Alternator : Megatron Control Panel Datakom Packaging Details : According to the customer's request, the generator standard packaging is a stretch film. The customer's request for special packaging is reflected in the price
Request for a quoteTurkey
Product origin: Kocaeli, Turkey Brand Name :Katana Generator Model Number : KD 53 D&M Rated Voltage : 230-400 V Speed:1500RPM Frequence: 50 HZ Type: 4-cycle Engine : DETROİT Engine Alternator:Megatron Options Battery Charger Controller: Datakom - Deepsea Packaging : According to the customer's request, the generator standard packaging is a stretch film. The customer's request for special packaging is reflected in the price
Request for a quoteTurkey
5 years or 3000 hours Certificate : ISO-CE Product Origin : Kocaeli, Turkey Brand Name : Katana Generator Model Number : KD 60 D&M Rated Voltage : 230-400V Speed :1500RPM Frequence : 50 HZ Type : Three Phase Alternator Engine : Detroit Engine Alternator : Megatron Product Name : Diesel Genertor Warranty : 3000 working hours 5 years Packaging : According to the customer's request, the generator standard packaging is a stretch film. The customer's request for special packaging is a reflected in the price
Request for a quoteOur company first 1999 with the service started with the production of generators in the range of 3 kVA - 16 kVA primarily, and the service has been intensively studied for the continuation of the continuity with the satisfaction of the customers. This rapid growth in a short time has made KATANA one of the leading companies in the sector, making it a respectable and reliable institution. Today our company is producing generators, land and marine engines in the range of 13 kVA-2000 kVA with 50 production staff, 20 technical and administrative personnel and a contribution to the country´s economy with its growing capital every day KATANA; It also aims to open up to the world with a human-oriented sense of responsibility, entrepreneurial ability to take risks, dynamic structure, and superior achievements. In line with this goal, he has been active in domestic and foreign business partnerships to become a global company. The first step of this aim was realized in Georgia, and in the ongoing process, participated in sectoral fairs in Europe, Central Asia, Africa, and Turkic Republics and conducted market analyzes and identified the products needed. Katana Power Products; the project management, the production by standards, the goal of purchasing quality materials from anywhere in the world, timely and at a reasonable cost, is constantly developing and growing to become a world brand with its technological facilities
Manufacturer/ Producer
KATANA GUÇ URUNLERI Gebze Guzeller Organize Sanayi Bolgesi
Yunus emre sok. no :3 gebze / kocaeli
41400 Gebze - Turkey
Germany
The CSN® HECT, HEVT and HECT/VT by Schniewindt combines proven sensor technology and opticaldigital data transfer according to the standard IEC 6185092, creating a future orientated solution for applications in high voltage AC substations. The required values to be measured are recorded in analog signal form by conventional sensor elements (R/C high voltage divider for voltage measurement and Rogowski coil for current measurement) on HVline potential and transferred to the RemoteDataModule (RDM) mounted in the head construction of the instrument transformer. The RDM converts the recorded data into a digital serial protocol and transmits them via optical fiber to the Merging Unit (MU), located in the control room. The distance between instrument transformer and MU can be up to 1 km. The MU transfers the data protocol of three instrument transformers into the protocol according to IEC 6185092. For signal output
Request for a quoteGermany
The IEC 6185092 LE Merging Unit is the optimal solution for process bus interfacing. It allows the consolidation of measurements made in the switchyard, feeding protection relays, meters and fault recorders located in the control room. The use of fiberoptical communications makes it inherently safe. By eliminating the majority of copper wiring, the CSN® Merging Unit addresses key technical and logistic challenges affecting the cost of substation design, construction and maintenance. The simple and disturbancefree architecture of the open IEC 6185092 process bus allows operation of relay, meter and faultrecording equipment of different manufacturers on the same bus. The IEC 6185092 LE Merging Unit collects data from conventional instrument transformers and converts the analog signals into a digital protocol