Belgium
Manufacturer/ Producer
Belgium
Combi 1.1 – Innovating product – Better and cheaper than Laminar Flow – Adjustable Air Nozzles for perfect airflow – Creates high efficiency Cleanroom Class ISO6 or even ISO5 – Installation: 1 day max. – Results within 30 minutes – Clean Air Capacity: 800 m3/hour maximum, with 1/4 of fresh air (optional) – Only needs W 90 cm x H 154 cm x D 34 cm of wall space – Quiet operating level – Max. distance between inside & outside unit: 25 meter To protect immune compromised patients To upgrade ICU’s, laboratories and O.T’s Note Pressure difference depends on air tightness of the room. For information and advice contact MedicCleanAir.
Request for a quoteBelgium
Air purification unit for cleaning room air The Pro air purification unit cleans the air inside the room. The Pro unit is used for the protection of vulnerable (immune-compromised) patients, protection against infectious patients, the elimination of aspergillus during renovation works, and for the upgrading of air quality in operating theatres, ICUs, isolation rooms. The Pro unit gives immediate results (within 20 minutes max) and once deployed maintains integrity of the air quality at all times. The life-time of the high efficiency particulate air filter inside the unit is therefore largely extended. The prefilters are supplied in packages and are easily changed.
Request for a quoteBelgium
Pre-filtration filters on the outside of the unit Indoor work leads to an increased concentration of aspergillus. In order to protect the high effiency particulate air filter inside the unit during building activities, pre-filtration frames with filters are added to the outside of the device. The life-time of the high efficiency particulate air filter inside the unit is therefore largely extended. The prefilters are supplied in packages and are easily changed.
Request for a quoteBelgium
Isolation Unit, 1-piece, for positive or negative room pressure This Isolation Unit is made for installation in suspended or false ceilings, and walls. Can be connected to an existing ventilation system or new tube system. Reccommended for installations were the point of extraction and supply are further away from eachother. Depending on the installation, positive (for immune-compromised) or negative (for infectious patients) pressure is generated inside the room (easily up to 20 Pascal). Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured. – Automatic differential pressure regulation – Automatic pressure loss alert – Filter detection by ID code (filter condition) – Complies with CDC guidelines (Centres for Disease Control and Prevention) Used in hospitals, clinics and medical facilities Immune-compromised patients Oncology, haematology, neonato
Request for a quoteMedicCleanAir: An efficient and clinically proven solution to reduce nosocomial infections, upgrade air quality, and create negative or positive pressure (isolation) in existing patient rooms. – Level ISO8 – 7 or even ISO6 with pressure difference up to 20 Pascal. – Installation time and results: 1 day max. Proof: 14 years of clinically proven track record with highly ranked University hospitals and with governmental specialists in infection control and epidemiology. 15 highly cited publications on the effectiveness of MedicCleanAir® technology from Belgium, Germany, Italy, UK, Iran, France, India and Saudi Arabia. Stop MERS and Coronavirus – Manage Tuberculosis Patients – Protect Staff and Immune Compromised patients. No more discussions about air quality in my department!
Germany
CSN® Dummy Load Resistors used as dummy loads for testing high frequency radio transmitter systems. Schniewindt had already supplied dummy load resistors with rated max. cont. power up to 1500 kW. CSN® Dummy Load Resistors are designed and manufactured individually to customer requirements and specific application.
Request for a quoteGermany
CSN® PreInsertion Resistors are used for limitation of transients during energisation process of transformers and HVDC VSC converter applications. CSN® Discharge Resistors are used for discharge of Capacitors, reactors and superconducting magnetic field coils. They are characterized by a high dielectric strength and energy absorption capacity. CSN® PreInsertion or Discharge Resistors are designed and manufactured individually to customer requirements and specific application.
Request for a quoteGermany
CSN® Neutral Earthing Resistors are used in power distribution systems for star point earthing of transformer or generator windings. According to the application (low or high ohmic neutral earthing type) pakkages made out of meander shaped stainless steel wire elements or CSN® Resistor Webs will be used as active material. Schniewindt has already supplied units for system voltages up to 380 kV and earth fault currents up to 70 kA. CSN® Neutral Earthing Resistors provide optimal solutions for your applications high or low resistance values outdoor or indoor operation reliable, nearly maintenancefree technology compact design with high power density reliable performance at all system voltages Every single CSN® Neutral Earthing Resistor is manufactured according to individual customer requirements.
Request for a quoteCreate one request and get multiple quotes form verified suppliers.