Description

The modular urinal valve system includes a shut-off valve and a solenoid operated cartridge valve with a nominal orifice DN 7.. The shut-off valve allows the manual shut off of the water supply for installation-friendly replacement of the valve, in the case of service, using a standard 8 mm Allen key. Cartridge valve body adapter without shut-off valve are also available (series 50.007.126). The cartridge valve is inserted in the valve body and secured by a gland nut, making removal for maintenance simple. All 50.007.101 series bi- and mono-stable cartridge valves can be used. For flushing the pipework before initial operation or after maintenance, the cartridge valve can be replaced by a plug. Technical changes reserved.

Product features

Housing PA 6/6 glass fibre reinforced
Plunger guide LCP
Plunger and spring Stainless steel
Membrane and sealings EPDM
Filter (in inlet) Stainless steel
Ways 2/2-way
Function bi stable, pulse controlled
Connection thread M28 x 1 or M29 x 1,5
Fitting position any
Media potable water and physically and chemically similar media
T-Medium 5 - 30 °C
T-Ambient 5 - 60 °C
DN DN Numerical size indication of the nominal free diameter (diameter nominal) of components fo 7 mm
Pressure range Pressure range Nominal pressure or range. 0,5 - 10,0 bar
Cv-Value 18 l/min @ 1 bar
Protection Type IP 65
Protection type Protection type Standard which defines the scope of protection of the electromag higher IP-classes on request
Insulation class B according to EN 60730
Nominal voltages 6 V DC
Operating voltage 4,0 - 6,9 V DC open/close
Nominal power 1,4 W
Nominal voltages 12 V DC
Voltage tolerance +10% -15%
Duty cycle Duty cycle Indicated as ED on equipment nameplates. It refers to the percentage opera 100%
Nominal power 1,7 W (12 V DC)