China
Manufacturer/ Producer
Oneding silicon Steel Group Co., Ltdwas founded in 2003. Now the registered capital has reached 912.24 million RMB. Oneding Group is not only the first private enterprise that produces cold-rolled electrical steel in China, but also the largest scale cold-rolled silicon steel producing and trading, stator & rotor laminations producing and trading, logistics as one of comprehensive company. Oneding Group headquarter locates in Fuzhou. There are two silicon steel sheet production plants, three punching bases, three trade centers and a large logistics center under the group. We own 20-year experience in silicon steel producing and trading and build the long-term strategic cooperation relationship with upstream large-scale steel enterprises. Besides, Oneding Group has accumulated many terminal customers. Like Emerson, TECO, TMEIC, SEW, Midea, ABB, Haier etc.
Manufacturer/ Producer
No. 1606, Building 4, Kaixuan Gardon, Shutang Street, Gulou District
350000 Fuzhou, Fujian - China
Germany
The CSN® HECT, HEVT and HECT/VT by Schniewindt combines proven sensor technology and opticaldigital data transfer according to the standard IEC 6185092, creating a future orientated solution for applications in high voltage AC substations. The required values to be measured are recorded in analog signal form by conventional sensor elements (R/C high voltage divider for voltage measurement and Rogowski coil for current measurement) on HVline potential and transferred to the RemoteDataModule (RDM) mounted in the head construction of the instrument transformer. The RDM converts the recorded data into a digital serial protocol and transmits them via optical fiber to the Merging Unit (MU), located in the control room. The distance between instrument transformer and MU can be up to 1 km. The MU transfers the data protocol of three instrument transformers into the protocol according to IEC 6185092. For signal output
Request for a quoteGermany
The IEC 6185092 LE Merging Unit is the optimal solution for process bus interfacing. It allows the consolidation of measurements made in the switchyard, feeding protection relays, meters and fault recorders located in the control room. The use of fiberoptical communications makes it inherently safe. By eliminating the majority of copper wiring, the CSN® Merging Unit addresses key technical and logistic challenges affecting the cost of substation design, construction and maintenance. The simple and disturbancefree architecture of the open IEC 6185092 process bus allows operation of relay, meter and faultrecording equipment of different manufacturers on the same bus. The IEC 6185092 LE Merging Unit collects data from conventional instrument transformers and converts the analog signals into a digital protocol
Request for a quoteCreate one request and get multiple quotes form verified suppliers.