PGC

Web icon

Description

With the very simple operation and the generated and saved measurement protocol, the documentation can be created quickly and completely reproduced. It is possible to save the measurement data in the device and to print it out again later. No tracer gas nor a second measuring device are required for use. The internal battery, the 230V charger or the 12V vehicle voltage can be used for the energy supply. All included in a complete set. Ethane is always contained in natural gas; evidence of this gas is also evidence of natural gas. A lengthy gas analysis is normally required to prove beyond any doubt that the measured gas concentration is actually natural gas and not swamp gas. This, also due to the sampling, a difficult and time- consuming process, is completely eliminated. Measurement and sampling directly at the borehole is easily possible. The printout can take place after the measurement.

  • Gas detectors
  • detectors
  • Leak detector
  • Gas detector

Product characteristics

Display
LCD display with 2 x 16 characters, illuminated
Measurement range
100ppm to 100 Vol.% Sample gas in the borehole
Gas
Hydrogen, methane, ethane and propane
Detection Limit
< 10 ppm Ethane (according to DVGW regulations)
Test Gas
50 ppm Ethane (according to DVGW regulations)
Temp. Range
0°C to 40°C
Protection Class
IP 54
Energy Supply
Battery (Lithium Ion Battery), 12V Kfz, 230V
Operation time
more than 200 measurements with one battery
Dimensions
158 x 63 x 229 mm
Weight
approx. 1 kg

Domain icon Manufacturer/ Producer

77933 Lahr - Germany

Contact