Position control on doors / casings in ATEX

ANATOM78S PL EEX and ANATOM78S OX EEX

Description

Contactless coded electronic sensor ATEX zone 0/20 (PL version) or 1/21 (OX version) Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking for PL version II 1 GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da Product used in combination with AWAX26XXL-EEX box ATEX marking for OX version II 2 GD Ex ia IIC T4 Gb Ex ia IIIC T135°C Db Product used in combination with AWAX26XXL-EEX box Machine Safety Level of performance with AWAX controller: up to PL = e Safety category: 4 with AWAX controller Time before dangerous failure: MTTFd = 277 years Max. activation distance: 10 mm, 4 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/12V redundant and 1 x PNP 15mA/12V contact Shock / vibrations: 30 G Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Total number of connectable sensors in series: 0 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 (PL version) or INOX 316L mirror polished (OX version) Electrical connection: 12m or more on request Water resistance: IP 67