Proline t-mass B 150 Thermal mass flowmeter

Description

The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.

Product characteristics

Measuring Principle
Thermal
Product headline
The flowmeter for cost‐effective measurement and easy monitoring of utility gases.
Sensor features
Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effect
Transmitter features
Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostic
Nominal diameter range
DN 80 to 1500 (3 to 60")
Wetted materials
Transducer: 1.4404 (316L); Insertion tube: 1.4404 (316L)54321 1.4435 (316L)
Measured variables
Mass flow, temperature, corrected volume flow, FAD volume flow
Max. measured error
3 % o.r.; 4 % o.r.; 5 % o.f.s.; (depending on chosen option of ordering feature "Calibration flow")
Measuring range
20 to 720 000 kg/h (45 to 1 587 600 lb/h); 20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
Max. process pressure
20 bar g (290 psi g)

Domain icon Manufacturer/ Producer

4153 Reinach Bl - Switzerland

Contact

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free