China
Manufacturer/ Producer
The product CAS NO is as follows: 1)CAS NO: 2495-39-82)CAS NO: 1561-92-83)CAS NO: 10035-04-84)CAS NO: 7791-18-65)CAS NO: 7647-14-5
OFS ONLINE FLUID SENSORIC GMBH
Germany
With SaveCost C, the parameterized hardness limit value is monitored in the range from 1 ppm to 18 ppm and the regeneration of the columns is triggered on the CLACK® control head if necessary. In addition to more operational safety, the softener generates up to 160% more soft water with less flushing water and salt. This also reduces operating costs by up to 60%. Monitoring and control is carried out on CLACK® control heads with the TWIN models; WS 1.0; WS 1.5; WS 2.0 and WS 3.0. With the integrated hardness sensor, the amount of soft water produced is monitored and forced regeneration is triggered when capacity is exhausted. The additional yield of soft water and the number of regenerations are displayed. In addition to the automatic self-monitoring, a chronological storage of operating data is integrated in the electronic operating diary (USB stick). A LAN data interface (Modbus) is available as an option.
OFS ONLINE FLUID SENSORIC GMBH
Germany
Softcontrol RM monitors the soft water produced by the softener for increased hardness concentrations and also triggers the regeneration of the softener in terms of quality. The monitoring of variable water hardness limit values from 1 ppm to 18 ppm takes place as well as the quality-controlled triggering of the regeneration of two columns of the softener. A continuous measurement takes place as long as water flows. Indicators are dispensed with and low-maintenance ion-selective sensors are used instead. The device has self-monitoring so that, in the event of service, information is provided automatically for less maintenance. The measured values are output on the display, via a 4 to 20 mA current loop and via a LAN data interface with Modbus / TCP. The data is also saved in the electronic operating log (USB stick). Installation and parameterization is easy to carry out on the device.
OFS ONLINE FLUID SENSORIC GMBH
Germany
Water hardness is influenced by changes in raw water, flow, pressure and bypass valve. The continuous monitoring of the water hardness behind a blending system with Softcontrol V-UE is therefore of great importance. The device monitors the limit value of the water hardness of blended water on a water softener approx. Every 30 seconds. The limit value can be parameterized in the range between 18 ppm and 360 ppm. The data is shown on the display, saved on the USB stick and output via a 4 to 20 mA current loop. The integrated ion-selective sensor works without the use of an indicator. Installation is simple, the limit value can be parameterized and the sensor, as the only common spare part, reports that it is easy to replace if necessary.
OFS ONLINE FLUID SENSORIC GMBH
Germany
Softcontrol Data offers individual setting options and a clear presentation of the information on the display. The device is a comprehensive alarm system for upstream water softening systems with high safety requirements for the soft water quality. The limit values for the water hardness can be set in the range from 1 ppm to 18 ppm based on the input water hardness. The measurement data and service messages are automatically saved in the readable, integrated USB stick and transmitted via a current loop and LAN interface with MODBUS / TCP. For increased operational and process reliability with the best user friendliness. A continuous measurement takes place approx. 2 times per minute as long as water is flowing. indicators are not used and an ion-selective sensor is used instead. This monitors itself and indicates the required exchange itself. This is usually the only maintenance on the device that has to be carried out around twice a year.