Description

SHIP TYPE CABLES Marking BIRTAS KABLO MYCY 1 x 1mm2 TS 2957 Part no GOST-R CE....mt Applications These cables are mainly used in permanent installations such as e.g. lighting, control circuits, power cables in engine rooms, in ships. They are very resistant to all conditions in the marine environment such as dry, wet and oil. As they are screened , these cables can be use in comunication systems, radio and electronic equipments. Cable Design Conductor Flexible copper wires, plain IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation PVC compound Lay-up Cores laid up in layers of optimum pitch Inner Sheath PVC compound Screen Braid of plain Cu wires, %85 coverage Outer sheath Oil and flame resistant special PVC compound Sheath colour Black

Product features

Standard IEC 92-3,TS 2957
Insulation resistance >20 MΩ.km
Rated voltage 0.6/1 kV
Test voltage 4000 V
Temperature range - 30 oC ~ + 70 oC Mobile : - 5 oC ~ + 50 oC
Min. bending radius 15 x D Multi-core:12 x D
Flame retardance test IEC 60332-1 & EN 50265-2-1