Description

Single point load cells specially designed for platform and hopper weighing. o Designed for off-center load o Maximum platform size: 800 x 800 mm o Material: anodised aluminium alloy o Protection class: IP64 o Easy to install o Complies with OIML / R60 up to 3000 d for scales in class III according to EN 45501 o Cable length: 3 m (other lengths available on request) Technical drawings available on datasheet

Product features

Accuracy class (-) 0.03 % F.S.
Combined error (non-linearity + hysteresis) (% F.S.*) <± 0.03
Repeatability error (% F.S.*) <± 0.015
Creep error over 30 min. (% F.S.*) <± 0.025
Zero shift after loading (% F.S.*) <± 0.0075
Reference temperature (°C) 23
Compensated temperature range (°C) -10...+45
Service temperature range (°C) -30...+70
Storage temperature range (°C) -50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C) <± 0.015
Temperature coefficient of zero signal (% F.S.*/10°C) <± 0.023
Zero balance (mV/V) ± 0.02
Nominal sensitivity (mV/V) 2
Sensitivity tolerance (%) <± 0.2
Input resistance (ohm(s)) 350 ± 2
Output resistance (ohm(s)) 350 ± 2
Insulation resistance (50 V) (Mohm(s)) > 5000
Reference excitation voltage (VDC) 10
Permissible nominal range of excitation voltage (VDC) 3...12
Safe load limit (% F.S.*) 150
Breaking load (% F.S.*) >300
Permissible dynamic loading (% F.S.*) 60
Static lateral force limit (% F.S.*) 100

Additional product literature

Need more information from the seller?