The system comprises two electrodes which are installed above the floor of the pumping station shaft and which issue an alarm message via the connected level relay when they come into contact with water. A sudden water leak in the shaft is detected immediately thus effectively preventing damage. Product features Level relay with connection terminals for potential-free messages for installation in the AWAcontrol control cabinet
Germany
If mobile phone reception is poor and there is a landline connection available, the automatic telephone dialler is a reliable alternative to fault message transmission by text message. Any fault messages are forwarded to different pre-programmed phone numbers. Product features For forwarding fault messages via the landline. Integrated microphone and control loudspeaker Voice messages to any number of recipients Digital message to one or more alarm receiving systems Remote query, remote control depending on device type Messages to pager or as text message depending on device type
Request for a quoteGermany
A GSM modem is a favourable option for transmitting plain text fault messages as text messages to operating staff‘s mobile phones for immediate notification of fault messages. The output of the message text can be freely configured. Text messages can be transmitted to several mobile numbers. A sufficiently good mobile phone network is required for the use of the GSM modem; alternatively an automatic telephone dialler can be used where a landline connection is available. Transmission of fault messages by text message and the mobile phone network. Product features Automatic alarm issued as text message when changes in state occur Freely definable message texts Cyclic alarm forwarding to up to 5 different numbers Analogue and/or digital inputs Straightforward configuration with PC and software Text message state query for all inputs and outputs Remote access with PC/laptop and status display on the screen
Request for a quoteGermany
2DFmaster AWAcontrol control system for STRATE sewage pumping stations with two pumps each and an installed overall motor rating of 0.75 kW to 75 kW each. Particularly suitable for building services engineering and municipal applications (twin systems), offers outstanding ease of use and functionality of the AWAmaster technology also for pumping capacities over 4 kW. LCD plain text display Thermal and electrical motor monitoring Manual – 0 – Automatic functions Pump switch-off through switch-off point with run-on time Acknowledgement button Electronic monitoring of the motor current Forced switch-on, switchover and alternation of pumps Internal acoustic alarm Collective fault message potential-free and potential-bound Backwater alarm potential-free All settings and fault messages retained after power failure Operating hours counter High resistance to interference Simple operation Level recorded either by internal pressure transducer, external 4 – 20 mA probe or float switch
Request for a quoteGermany
the economical alternative Replacement for STRATE 1DF2 and 2DF2 pump controllers suitable for connection to all STRATE fill level recording systems: contact-based or contactless the 2DF2 plus also handles dual level measurement: Sensor/pilot tube and sensor/contactor for outstanding operational reliability the current level and operating hours are always shown on the display
Request for a quote