Description

For measurement of high mass flow rates for dry solids from the exit of pre feeding devices, e. g. screw conveyors, air slides, rotary valves, bucket elevators, etc. ● Most non-metallic solids can be measured ● Can be installed on round pipes or ducts ● No real upper limit of mass flow ● Maximum pressure 10 bar ● Dust tight ● No flow restrictions to the process flow (wear resistant ceramic liner) ● The mass flow measurement is independent of flow characteristics ● Maximum temperature, 12O °C ● Can be installed at an angle ● Small footprint, 220 mm (DN 100), 290 mm (DN 150), 310 mm (DN 200) ● No moving parts, hence no maintenance

Product features

Housing Steel St 52, powder-coated (optional stainless steel 1.4571 NW 100/150/200 mm, flange according EN 1
Inner pipe Ceramic AL2O3
Protection category IP 65
Operating temperature 0 ... + 60 °C Sensor pipe: - 20 ... + 120 °C
Max. working pressure 1 bar, optional 10 bar
Working frequency 88 kHz
Transmitting power Max. 2 mW
Weight Depending on model
Accuracy ± 3 % (based on end of measuring range and calibrated material)
Power supply 110/240 V AC, 50 Hz, optional 24 V DC
Power comsumption 20 W / 24 VA
Operating temperature - 10... + 45 °C
Dimensions 258 x 237 x 174 mm (W x H x D)
Weight Approx. 2.5 kg
RS 485 interface ModBus
Terminal clamp wire size 0.2 - 2.5 mm_ [AWG 24-14]
Current output signal 2 x 4 ... 20 mA (0 ... 20 mA), load < 500 Ohm
Serial output RS 485, ModBus protocol
Data backup Flash memory
Cable glands 3 x M 16 (4.5 - 10 mm Ø)