Description

PVC INSULATED, INSTALLATION CABLE FOR COMMUNICATIONS Marking BIRTAS KABLO J-YY ….Bd 10 x 2 x 0.60mm 1407 03 020 Part no GOST-R CE....mt Applications These cables are used for signal and data communications as an fixed indoor installations. Additionally these cables are suitable for applications at small bending radius. Cable Design Conductor Plain copper conductor, solid Insulation PVC compound , YI1; VDE 0207-4 Core identification IEC 708 * Core identification differs from VDE 0815 Lay-up Star quads, each 5 star quads stranded in a units, each unit laid up in layers Separator Polyester tape Outer sheath PVC compound, YM1; VDE 0207-5 Sheath colour RAL 7032,Grey

Product features

Standard VDE 0815
Conductor resistance 0,60 mm = 130 Ω/km
Insulation resistance Min. 100 MΩ.km
Mutual Capacitance Max. 100 nF/km * This value may be exceeded by 20% by cables with up to 4 pairs
Capacity Unbalanced Max. 300 pF / 100 mt * 20% of the values, at least one value up to 500 pF permitted
Operating voltage, peak Max. 300 V
Test voltage 800 V / 1000 V
Temperature range - 30 oC ~ + 70 oC Mobile : - 5 oC ~ + 50 oC
Min. bending radius 7,5xD
Flame retardance test IEC 60332-1 & EN 50265-2-1