Accuracy universal load cells, easy to install. o Wide range of capacities: 10 kN (1 t) up to 50 MN (5.000 t) o Compact design o Protection class: IP66 o Material: stainless steel (5100)**, nickel-plated steel (5105) o Cable length: see drawing table - CL (other lengths available on request) o Also available as standard reference load cells according to ISO 376 (classes "1", ''0,5'' and ''00'' - see specific data sheet 5105-ISO) Technical drawings available on datasheet

Product features

Accuracy class (-) 0.25 % F.S.
Combined error (non-linearity + hysteresis) (% F.S.*) <± 0.25
Repeatability error (% F.S.*) <± 0.1
Creep error over 30 min. (% F.S.*) <± 0.1
Zero shift after loading (% F.S.*) <± 0.025
Reference temperature (°C) 23
Compensated temperature range (°C) -10...+45
Service temperature range (°C) -25...+70
Storage temperature range (°C) -50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C) <± 0.05
Temperature coefficient of zero signal (% F.S.*/10°C) <± 0.035
Zero balance (mV/V) ± 0.02
Nominal sensitivity (mV/V) 1...2
Sensitivity tolerance (%) <± 0.3
Input resistance (ohm(s)) 350...700 ± 2
Output resistance (ohm(s)) 350...700 ± 2
Insulation resistance (50 V) (Mohm(s)) > 5000
Reference excitation voltage (VDC) 10
Permissible nominal range of excitation voltage (VDC) 3...12
Safe load limit (% F.S.*) 150
Breaking load (% F.S.*) >300