• Digital & Analog Thermocouple Connector
  • Displays and transmitters
  • Connector
  • Thermocouple

Product features

Range From -20 – +120 °C To 0 – +1250 °C
Type K, J, T, …
Accuracy Digital output ± 0.5 °C
Cold junction error ± 0.7 °C
Accuracy Analog output ± 0.25 % FS
Drift vs Ambiant Temperature Analog output ± 0.25 % FS
Sensitivity Linear (See calibration table) mV/°C
Sampling frequency 5 Hz
Supply Voltage 5–16 V or 12–33 V
Supply Current 3 mA
Output Voltage 0–5 V or 0–10 V
Output Impedance 47 Ω
Digital output* ASCII @ 5hz, 9600 Bauds
Calibrator Fluke 714
Dimension “P” type 35 x 20 x 10 mm
Material “P” type Plastic
Dimension “A” type 32.5 x 19 x 10 mm
Material “A” type Aluminium
Weight 15 g
Protection IP53
Vibration test 20Gpp5’
Shock 500 G
Operating Temp -40 to +125 °C
Storage Temp -40 to + 125 °C

Need more information from the seller?