Description

Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using PROFIBUS® PA communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.

Measurement - Equipment & Instruments

Product features

Measuring Principle Head transmitter
Input 2 x RTD, TC, Ohm, mV
Output PROFIBUS PA
Auxiliary power supply 9...32 V DC (PROFIBUS PA); 9...17,5 V DC (FISCO/FNICO)
Communication PROFIBUS PA
Installation Terminal head form B
Accuracy (Pt100) <= 0,1 K; (Pt100) <= 0,18 °F
Galvanic isolation yes
Certification ATEX II2D Ex tb IIIC Db; ATEX II1G Ex ia IIC T4/T5/T6; ATEX II3G Ex nA IIC T6; ATEX II3D Ex tc IIIC