Description

Electrodynamic, continuous measurement and monitoring of dust emissions according to QAL1 certified according to QAL1 with regard to standards EN 14181 and EN 13284-2 as well as EN 15267-3, additional TÜV approved according to 13., 17. and 27. BImSchV (latest version) automatic zero-, span- and contamination-check to fulfill QAL3-requirement "PCME ProController“ for up to 32 sensor, alternative “PCME Interface Module” for 1 sensor reduction of material-, downtime- and maintenance costs flue-gas temperatures up to 250 °C (optional 500 °C, 400 °C for Ex-version digital inputs and outputs external connections: USB 2.0 (type A), ethernet (RJ45/100 Mb/s)

Product features

Ambient Air Temperature -25 ... +55 °C
Stack Gas Temperature 250 °C standard
Stack Connection Hole pattern to suit DN 80 PN 10/PN 16 or Ansi
Enclosure Rating IP 65
Power Requirements 24 V DC
Cable Entries 3 x M20
Air purge connection Optional air purge fitting with external supply of 5-10 litres/min
Outputs 4 x 4 ... 20 mA (500 Ω) a1x RS 485 (ModBus RTU) 4 x relais (2 A @ 250 V)
Inputs Plant stop signal Cleaning andmultiple calibration
Emission data logs Capacity stated for 4 sensors with QAL3 3 months @ 15 min 7 days @ 1 minute 2 hours @ 1 second
Enclosure size 263 x 160 x 91 mm
Power supply 90 ... 260 VAC, 1 A

Need more information from the seller?