• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • electronic relays

Results for

Electronic relays - Import export

China

Relay is an automatic switch element with isolation function, which is widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment.

Request for a quote

China

Relay is an automatic switch element with isolation function, which is widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment.

Request for a quote

Belgium

Verified by Europages

"2 CONDENSATORS SINGLE-PHASE MOTORS (OUR CODE: MML) - with centrifugal coupler or electronic relay - Motors available in 230V - 1500 or 3000t/min - Aluminium frame - Multiposition - IP55 protection - Shape B3-B5-B14 -B35-B34 - Stored between 0,37 and 3,7kW"

Request for a quote

Germany

Verified by Europages

OKS 1105 prevents the formation of electrically conductive layers and minimises the risk of flashovers and dielectric losses. The insulators and switchgear covered with the paste thus maintain a good insulation resistance. Sealing lubrication for electrical or electronic equipment such as relays, plug-in connections, cable lugs and lamp sockets Protection of insulators and switchgear in humid atmospheres, for example of junction boxes, screw terminals, overload cutouts at high-voltage pylons, connecting cables and terminal connections Lubricant for plastic screw connections and other moving parts of metal, ceramic, plastic Advantages and benefits Excellent water repellent properties Excellent surface wetting Good adhesion on glass, porcelain and plastics Stable consistency across a wide temperature range Very good resistance to chemical and weather-based influences (e.g. ozone, UV radiation) Neutral with regard to many materials

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 100mA Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/48V redundant / 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Indication: LED indicating code absence Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -25°C to +60°C Marking: label + serial no. for traceability

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Manages person entry in hazard zones using an electrical locking key Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Electrical locking key with position contact Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 2xPNP 250mA auxiliary (open/closed door and locking/unlocking of contacts) Detection encoding: mono-code inviolable Note: two-color LED indicates the key locking position; white LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: Polycarbonate Electrical connection: M12 metal base Water resistance: IP 65 Temperature: -15°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Up to 8 zone differentiation codes Safety contacts 2A / 250V • Level of performance without an external controller: PL = c • Level of performance with AWAX controller: up to PL = e • Safety category without an external controller: 1 • Cycle before dangerous failure: B10d = 2,000,000 at 2A • Max. activation distance 3SSR24V/5SSR24BX/5SSR24BX-US: 8 mm, 2 mm hysteresis • Max. activation distance 2SSR24V/2SSR24BX: 4 mm, 2 mm hysteresis • Safety contacts/diagnostics 3SSR24V: 1 x NO 2A/250V / 1 x NF 2A/250V auxiliary • Security contacts/diagnostics 5SSR24BX and 5SSR24BX-US: 2 x NO 2A/250V / 1 x PNP NF 250mA auxiliary (24V) • Security contacts 2SSR24V: 2 x NO 2A/250V • Security contacts 2SSR24BX: 1 x NO 2A/250V and 1 x NF 2A/250V • Detection encoding 3SSR24V, 5SSR24BX/5SSR24BX-US: single inviolable code • Detection encoding 2SSR24V and 2SSR24BX: 8 inviolable codes • Indicators 2SSR24V, 2SSR24BX, 3SSR24V and 5SSR24BX: Red LED indicating code absence (not transmitter) • Indicator 5SSR24BX-US: Two-color red/green LED • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 2 (double wall brackets) • Matierial PA6: 2SSR24V, 2SSR24BX, 3SSR24V, 5SSR24BX, 5SSR24BX-MKT and 5SSR24BX-US • Material INOX 316L mirror polished: 5SSR24BX-OX and 5SSR24BX-OX-MKT • Electrical Connection: 3, 6, 12m cable or 50cm cord with M12 connector (UL20549 PUR) for5SSR24BX-OX and 5SSR24BX-OX-MKT • Water resistance: IP 67/68 (PA6) or IP 69Kwith stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Suitable for groove profiles and single or double doors Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 8 mm, 3 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic (SR version) or Manual (AR version) Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection) Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle after dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Security contacts / diagnostics AMX5 / AMX5CM12: 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary Security contacts AMX4: 2 x NO 2A/48V redundant Security contacts / diagnostics AMX3: 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ⇥or PC (AMX5CM12) Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12) Water resistance: IP 67/68 (PA6 / PC) or IP 69K with stainless steel - new generation Temperature: -25°C to +60°C Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12 UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)

Request for a quote
Filters

Results for

Electronic relays - Import export

Number of results

11 Products