• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • explosion-proof - equipment

Results for

Explosion-proof - equipment - Import export

Germany

Germany

Verified by Europages

Explosion-proof heaters - ATEX – Standard. Explosion-proof heaters are used in many industrial or commercial applications that are classified as hazardous areas. Our appliances are used to heat the ambient air of hazardous areas in zone 1 and 2, typically in chemical industries, paint and lacquer industries, sewage plants and mining. Heaters made of high-grade stainless steel are recommended for aggressive environments (e.g. sewage plants), while heaters with a painted or coated surface, also available with protection basket, are sufficient for standard applications. Available on request: further types of explosion-proof heaters and our technical data sheets, as well as the TR-CU certificate.

Request for a quote

Germany

Applications: Large sized drums, barrels, containers; road tank trucks, tank trailers, tank containers, silo trucks, silo trailer, railway wagons

Request for a quote

Germany

SEK-3 establishes a monitored equipotential bonding of very low resistance between ship and pier which counteracts the physical effect of electrical potential difference. This explosion protection measure prevents uncontrolled sparking when handling conductive elements at the terminal. In addition, the SEK-3 signals unsafe situations (such as over-voltage or over-current caused by active sources) by flashing LEDs and switching off the corresponding control outputs.

Request for a quote

Germany

The Overfill Prevention Controller EUS-2 is the central part of the overfill prevention system according to European VOC Directive 94/63/EC and American API RP 1004. EUS-2 monitors the level sensors at the tanker compartments, the truck grounding and the vapor recovery connection. The filling process is interrupted immediately at the loading gantry, if a critical situation is detected. The controller is able to detect the type of truck installation and activates the required operatingmode automatically. This interoperability allows to load trucks of different carriers.

Request for a quote

Germany

DO YOU FILL OR EMPTY TANK TRUCKS, SILO TRUCKS OR RAILWAY WAGONS? During loading and unloading inflammable liquids or solids an explosive gas and dust atmosphere may arise – a single spark can be sufficient to initiate an explosion. To prevent this, the occurring electrostatic charges must be discharged safely. TIMM’s Grounding Control Devices ensure static electricity is discharged to the ground by a grounding cable and continuously monitor the grounding quality. If there is an interruption of the grounding connection, the filling process will be interrupted immediately.

Request for a quote

Germany

Application: Permanent grounding connection between plant components or use as replacement part for existing TIMM Bite clamp + coiled cable assemblies.

Request for a quote

Germany

Applications: Small to medium sized drums, barrels, containers, canisters, buckets, oil cans, filling funnels and small plant components

Request for a quote

Germany

Application: Electrostatic grounding in the vicinity of a designated plant grounding point, to which the extendable grounding cable is permanently attached by its cable lug.

Request for a quote

Germany

DO YOU FILL OR EMPTY BIG BAGS? Please remember that many dusts in conjunction with air have a high risk of explosion. Flours, sugars or aluminum dusts are well known as an explosion hazard. But even the dust of products such as fertilizers, rubber, tobacco, spices and many other substances can cause explosions. Therefore, when processing such products, conductive big bags must be used. Grounding is required for these types of big bags to prevent ignition due to electrostatic charges. PRODUCT BENEFITS * For all FIBC type C according to IEC 61340-4-4 (10^7 Ω and 10^8 Ω) * Tamper-proof through digital measurement technology and automatic object recognition * Simultaneous monitoring of two big bags * Relay and NAMUR control outputs * Autodiagnosis system for permanent self-monitoring of all safety-related functions * Easy handling thanks to cable quick couplings and the integrated plain text display * Mounting the main unit at a distance of up to 20m from the workplace poss

Request for a quote

Germany

The danger of electrostatic charges must always be observed when loading, unloading or handling bulk solids or inflammable liquids in the petrochemical, chemical, gas, as well as in the food and feed industry. For application with containers, IBCs, barrels or trays, the EKX-4 (2-pole) is the Grounding Control Device to choose. APPLICATION AREAS: EKX-4 (2-pole) is mounted stationary, close to the loading/unloading gantry. It is used in gas and dust hazardous areas of zone 1 and 21 for objects to be grounded, that cannot be detected by the standard 1-pole Grounding Control Device EKX-4 such as containers, IBCs or barrels. Further areas of application are the grounding of materials handled with trays on conveyors in automated industrial processes.

Request for a quote

Germany

Application: Permanent grounding connection between plant components or use as replacement part for existing TIMM Bite clamp + straight cable assemblies.

Request for a quote

Germany

- For contactless reading and writing of RFID chip cards - Used in e.g. refineries, tank farms, chemical industry, medical industry, food industry or power plants - Allows the build-up of intrinsically safe access control and identification systems - Application areas: loading at filling gantries, weighing, entry and exit area - High protection against rough environmental conditions due to sturdy aluminum housing (optional available as stainless steel housing) - Explosion protection according to European ATEX-standard 2014/34/EU BENEFITS - Type of protection IIC - Contactless reading - Tamper-proof by additional data encryption via a special Timm Elektronik card coding - Temporary data at chip cards can be saved and recalled - Individual, customer-specific coding possible

Request for a quote

Germany

- For use during loading and unloading of tank trucks, silo trucks and rail tank cars - Controlled derivation of the static electricity - Use in gas and dust hazardous areas of zone 1 (equipment category II 2 G) and 21 (II 2 D) - Immediate interruption of the loading operation when unsafe grounding connection consists - EAC Ex approval according to the currently relevant TR-CU 012/2011 regulation

Request for a quote

Germany

Application: Electrostatic grounding and potential equalization at any place in your work environment. The second clamp can be attached to the nearest plant grounding point or a grounded object.

Request for a quote

Germany

Applications: Small cans, canister, buckets, funnels; filling and pouring on work and laboratory benches; earthing of very small plant components or when using small drum pumps or stirrers

Request for a quote

Germany

Application: Electrostatic grounding and potential equalization at any place in your work environment. The second clamp can be attached to the nearest plant grounding point or a grounded object.

Request for a quote

Germany

Applications: Medium to small sized drums, barrels, containers, canisters, buckets, oil cans, filling funnels and small plant components

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Application: Electrostatic grounding in the vicinity of a designated plant grounding point, to which the grounding cable is permanently attached by its cable lug.

Request for a quote

Germany

Applications: Large to medium sized drums, barrels, containers, buckets and canisters; road tank trucks, tank trailers, tank containers, silo trucks, silo trailer, railway tank wagons

Request for a quote

Germany

Verified by Europages

CSN® EXPLOSIONPROOF SPACE HEATERS CSN® explosionproof space heaters are used for heating zone 1 and 2 hazardous areas. Standard devices are available in the common temperature classes T1 to T4; temperature classes T5 and T6 can be offered on request. The use of finned tubes for the CSN® explosionproof space heaters is the most economical solution for heat transfer in the field of electric heaters. By coiling corrugated helical fins on tubes of different alloys, we obtain extremely large tubes surfaces and, consequently, low temperatures on their surfaces. We use this interaction to produce explosionproof space heaters on a highquality level. CSN® explosionproof space heaters with coiled fins are intended for horizontal mounting and suitable for both wall and floor mounting (for permanent installation)

Request for a quote