Germany, Waiblingen
..."flowtherm Ex" is a multifunctional handheld device with a data logger for accurately measuring flow, flow velocity, temperature, pressure, and other parameters in the Ex area of Zone 1. Measurement Parameters: - Flow velocity - Volumetric flow rate - Standard volumetric flow rate - Mass flow rate - Temperature - Other freely definable physical quantities, as long as they can be measured or...
... is possible to measure residual oil vapor content, residual humidity, flow rate, and pressure accurately and with excellent precision. Our monitoring and data logging make it accessible to you and your employees at a glance, ensuring process safety and the quality of your products.
Germany, Wertheim
...The first flow meter with a touchscreen display and backlighting impresses with its simple, user-friendly display and operation, the multilingual interface, and its compact design. Thanks to the rotating eccentric disc and a magnet, it enables accurate measurement of the volumetric flow rate, measuring thin to medium-viscosity media such as water and mineral oils precisely, quickly, and above all...
...The LM OG TA lubricant oil meter is used as a flow meter in lubrication systems for engine workshops and combined heat and power plants. The maximum flow rate can be up to 35 l/min.
...Variable volume flow controllers are used to maintain air flows under changing pressure conditions. A complete shut-off is possible through an integrated sealing shut-off valve. The effective pressure measurement is carried out by an integrated Venturi nozzle. The volume flow can range from 50 to 4500 m³/h. Measuring nozzles are available in nominal diameters of 110-400 mm connection diameter. Standard materials available are PP and PVC. Special materials are available upon request. For more information, please visit our website or contact us directly.
Germany, Duisburg
... equipped with a needle valve for precise flow value adjustment. The DK37 M8 is supplied with vertical or horizontal process connections for NPT or G threads, flange adapters, and numerous other connection options. To provide a constant flow rate even with variations in inlet or outlet pressure, the VA flow meter is also available with flow regulators. It has approvals for use in hazardous areas...
Germany, Thierstein
...The differential pressure transmitter DPT 100 has been especially designed for fast test processes in leakage and flow measurement, where a fast response time and high sampling rate are necessary. The compact design of the DPT 100 facilitates the use in standardised applications, e. g., and the installation in 19“ Rack. The DPT 100 with optionally RS485 interface uses the communication...
Germany, Heinsberg
...The Trotec PC200 Particle Counter features 6 measuring channels (0.3, 0.5, 1.0, 2.5, 5.0 and 10.0 μm) with three counting modes (concentration, cumulative and differential) and counting efficiency of 50% at 0.3 μm and 100% for particles beyond 0.45 μm. The internal pump allows flow rate of 2.83 l/min (0.1 ft³/min) and the zero count is < 1 particles / 5 min with a coincidence loss of 5%, 2...
... critical nozzles can be combined, depending on customer requirements. EP offers different designs for the register: Drum Design, Block Design & Register Design. Another variant is a mobile system: The EP SMF® - Mobile Flow Calibrator - a compact measuring system for flow calibration. EP Ehrler Prüftechnik manufactures single nozzles in the flow rate range from 0.005 to 2000 m³/h. In addition to our standard range, we also manufacture customer-specific nozzles that are perfectly designed for your application in compliance with DIN EN ISO 9300*. ...
Germany, Hofheim Am Taunus
...The URM type float flow meter and switch operates based on the well-known float measurement principle. It is used to measure flow in closed piping systems. The medium flows through a glass measuring tube that expands conically upwards from bottom to top. The float is lifted as a result, indicating the respective flow rate on the scale attached to the measuring cone. To monitor flow limit values...
... force introduction components are required to ensure that the line of force action aligns as precisely as possible with the geometric axis of the force sensor being tested (concentric loading). It is also very important that no lateral forces or moments are applied to the force sensor. Measurement accuracy: ± 0.001 % of full scale. Measurement rate: 0.1 ... 1200/s (DC); 0.1 ... 2/s (AC) Sensor type...
Germany, Mülheim
... in air ducts and air conditioning equipment. Because of the calorimetric mode the media temperature is also monitored. Flow rate measurement In addition to reproducibility, flow-rate measurement demands a defined degree of accuracy. The flow meters continuously and accurately measure a defined volume of a fluid per unit of time and are suitable for applications where qualitatively consistent process results and a steady supply of fluids is essential. We offer flow meters with calorimetric, magnetic-inductive and Vortex measurement principle for various areas of application.
Germany, Maxdorf
...The emtechnik flow meter was developed especially for measuring air with different flow ranges. All sealing surfaces and threads are produced without seams. On request we are also able to offer flow meters customised to specific customer specifications with special measuring ranges and measurement acquisition (annular proximity switch or reed switch). To do this we need details regarding medium, pressure, temperature, measuring range, viscosity and density. Flow Rate Air:0,2-2,0l/min...
...The Valve-Tronic Plus™ is designed for use in highly demanding industrial applications that require accurate flow control and measurement. It can function as a stand-alone controller for basic applications or become an integral part of a process control system for automatic flow control. FEATURES • Large LCD displays actual flow rate, totalized flow, valve position, alarms, and diagnostic...
...Fully automatic end-of-line tester for checking the functionality of oil pumps under specific operating conditions Measurement principle: Test specimen is integrated into the oil circuit Application of parameters (pressure, temperature, speed) Collection of measurement data (flow rate, speed, torque…) Properties: 100% testing High testing throughput, short cycle time...
...Elcometer 4695 Contrast Cards/Drawdown Cards These cards feature proven diagonal stripe patterns with a strong visual impact that highlight variations in opacity. They are commonly used to determine the hiding power in conjunction with drawdown and coating methods. Flow Rate Cards (Card 8H) have an area of exactly 0.1 square meters (approximately one square foot) and are designed for testing the hiding power of applied coatings with specified flow rates according to ASTM Method D 344. Leneta Card 8B: 194 x 289 mm Leneta Card 8H: 286 x 438 mm...
... safe, reliable and low-maintenance recording of flows is required. This includes e.g. all automation and chemical industries in the most varied areas, such as cooling circuit monitoring, monitoring the flow rate of process fluids, monitoring metering processes or also for pump protection.
Germany, Rain
...IFA Technology considers your individual requirements and builds customised dosing systems for you. Volumetric dosing is carried out on a quantity basis by measuring the flow rate of liquids or bulk materials. Application-dependent measuring systems are used in our volumetric dosing systems. These make it possible to provide the specified quantity of material at a defined point in time in a defined ratio. The continuous inline dosing via flow measurement technology or dosing pumps with linear characteristic curve enables recipe-accurate dosing of liquids and bulk materials in a small space.
Germany, Hammelburg
...Filter regulator Temperature range: -10° to +60° C Category Compressed-air technology / Compressed air preparation / Filter regulator Product number supplier 301804337 Adj.-range bar:1,5 - 12 Flow rate l/min:11500 Inner thread:G 1"-11 Measurement connection thread:G 1/4"-19 Series:3 Zollnr:84811005 Weight:1 kg Content:1 STK Barcode:301804337 Price Unit:1 Packaging Unit:1 quantity min:1 VAT key:19.00 %...
Germany, Katzhütte
...The melt flow index (Meltflowindex, MFI), also known as the melt flow rate (Meltflowrate, MFR), is measured according to DIN EN ISO 1133. It is used to determine the flow properties of plastic melts and is expressed in g/10min. Our modern measuring devices undergo annual calibration to ensure the most accurate measurement possible.
Germany, Villingen-Schwenningen
...The DS 400 set for consumption measurement displays the current flow rate in m³/h, l/min, etc., as well as the consumption in m³ or liters, and reliably and automatically records the values.
Germany, Asslar
... of physical values such as temperature, pressure, humidity, fill level, positioning, vibration, flow rate, power, torque, speed, ultrasound, infrared, composition, and concentration of gases and liquids, as well as adherence to measurement tolerances and production control, are of utmost importance.
... millimeter of strip thickness, they meet the demands of modern rolling mills. Contact measuring devices adapt to the strip flow and follow wavy material. Measuring material: Metal strip Maximum strip temperature: 120 °C (up to 200 °C with increased measurement uncertainty) Measurement resolution: 0.1 µm Sampling rate: 1 kHz Integration time Ti: 1 – 2,000 ms Protection class: Measuring head: IP64; Pneumatic cabinet: IP55; Control cabinet: IP55 Compressed air supply: Pressure: min. 5 bar; Volume: max. 7 m³/h...
Germany, Hohen Neuendorf Ot Bergfelde
...The FST030 is designed based on the latest developments in digital signal processing (DSP) and is optimized for high measurement performance, short response times, high immunity to process noise, and easy installation, commissioning, and maintenance. The FST030 measuring transducer provides precise multi-parameter measurements of volumetric flow, standard volumetric flow, density, mass flow...
Germany, Crailsheim
... technology, cold-welded · Load cell supply 10V · Connection 4/6-wire · Sensitivity 1mV/V-4.0mV/V · Maximum number of measurements 4000/s · Accuracies: · Zero point 0.001% / K · Weight 0.002% / K · Load above nominal load 0.002% · Weighing range freely adjustable · Measurement value filter multi-stage · Filter stages adjustable · Serial interface TTY (20mA Current Loop). · Transmission rate 1200 Baud, 9600 Baud · Corner adjustment integrated via software · Calibration capable...
... the outlet flow of the test part. The design of the measuring section results in laminar flow. The resulting pressure difference is directly proportional to the volume flow rate. With the optionally available electronic pressure regulator and flow calibrations at up to four measuring section pressures, the application range is expanded. Special variant: The CETATEST 915-G is a fully automatic flow...
...TGF600 Screw-in thermal mass flowmeters for small pipe size gas meausred Inline type can be installed/removed without stopping the line Minimum flow rate down to 0.3m/s, 1:100 super wide turndown ratio No moving part, almost no pressure loss Direct mass flow measurement, do not require temperature or pressure compensation TGF600 Series screw-in inline thermal mass flowmeters measures the gas...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play