Safety management in a compact 22.5 mm format Mono or two-channel with wiring. "Low consumption" Inputs Removable terminals Performance level with AWAX controller: PL = d Safety category: 3 (two-channel) Safety Integrity Level: SIL 2 Time before dangerous failure: MTTFd = 240 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 2x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant + 1x NO static 400 mA Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Version for mechanical or touch buttons KOB101T Controls the position of the press Removable terminals Performance level with AWAX controller: PL = e Safety category: IIIC Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 60 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: automatic with simultaneity control at 400 ms Position control: high press position contact input Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: INERIS 0080.5486.520.04.12.0059

Request for a quote

France

Add 4 power safety lines at 8A/250V with a safety PLC or control box without loss of Safety Class Compact format 22.5 mm/removable terminals Level of performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 4x NO 8A/250V redundant / 1x NF redundant in series (test) and 8A/250V parallel (information) C4SX indicators: 2 LEDs C5SX indicators: 2 LEDs Reset: automatic Number of inputs: 1 (C4SX) and 2 (C5SX) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Compact 45 mm format Two position key switch: free and captive Removable terminals Level of performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 4x NO 8A/250V redundant / 1x NF redundant in series (test) and 8A/250V parallel (information) Indicators: 2 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C