In electric equipment and devices, as well as in electric system of railway.The conductor is made from copper multi-core wire by twisting, class IV flexibility according to standard GOST 22483-2012. Nominal section of the conductor is 1.5-up to 150mm2.according to the sections it is as follows: 1,5 : 6mm2 inclusive 50m 10 : 25mm2 inclusive 2000m 35 : 70mm2 inclusive 1000m 95 : 150mm2 inclusive 500m By the request and agreement with the customer conductors with different construction length can be manufactured.

Request for a quote

Georgia

The non-halogen elevated fire hazard cable is designed to transmit and distribute electricity to stationary devices at nominal voltages of 0.660 kW and 1 Hz at 50 Hz. In the air, with anti-ultraviolet radiation protection and where there is no danger of mechanical damage of the cable, as well as for low corrosion activity in the soil (in the trenches), but in a protective tube.Aluminum wires with a cross section of 2.5-50 mm2 are made with single wire first class flexibility up to 70-240 mm2 with twisted multi-wire wires with 2nd class flexibility, standard IEC60228: 2004. At the request of the customer, it is allowed to make multi-wire cross section 16: 50. The number of cores in the cable: 1,2,3,4,52,5-16mm2 450 m 25-70mm2 300 m 95-240mm2 200 m In case of delivery coils (“bundle”), the construction length is agreed with the customer. It is allowed to make cables of different construction lengths.

Request for a quote

Georgia

For fixed connection on electric appliances, equipment, gathering mounts of electric distribution appliances for rated alternating voltage up to 660V frequency 100Hz, or direct current1000V. Used for laying in buildings, channels, tunnels if there is no danger of mechanical influenceThe structure of conductor core is multi-wire and conforms to 3 and 4 class flexibility according to the standard 22483-77. The section of conductor core is 0.75, 1.0, 1.5, 2.5, 4, 6mm2. Number of cores in the cable: 0,75-2,5mm2.-4, 5, 7, 10, 14, 19, 27, 37 4 and 6mm2-4, 7, 10In each bundle by existence of counting pair, which differs in color from other cores. Labeling can be done by means of inscription of separate numbers on insulated cores or distinctive colors of insulation can be used. While numeric labeling the color of figures must be different from the color of the insulation of the core. On the surface of the cover an inscription is made: “JSC Sakcable”, cable brand, section and manufacture year

Request for a quote

Georgia

For fixed connection on electric appliances, equipment, gathering mounts of electric distribution appliances for rated alternating voltage up to 660V frequency 100Hz, or direct current1000V. Used for laying in buildings, channels, tunnels if there is no danger of mechanical influenceIn each bundle by existence of counting pair, which differs in color from other cores. Labeling can be done by means of inscription of separate numbers on insulated cores or distinctive colors of insulation can be used. While numeric labeling the color of figures must be different from the color of the insulation of the core. On the surface of the cover an inscription is made: “JSC Sakcable”, cable brand, section and manufacture year

Request for a quote

Georgia

For fixed connection on electric appliances, equipment, gathering mounts of electric distribution appliances for rated alternating voltage 660V, up to 100 Hz , or direct current 1000V. Used for laying in buildings, channels, tunnels if there is no danger of mechanical influence on the cables. During laying in single layer the cable is flame retardantThe structure of conductor core is single-wire and conforms to 1 class flexibility according to the standard 22483-2012. The section of conductor core is 2,5; 4; 6; 10mm2. Number of cores in the cable: 2.5mm2-4, 5, 7, 10, 14, 19; 27; 37 4: 10mm2-4, 7, 10 During laying in single layer the cable is flame retardantIn each bundle by existence of counting pair, which differs in color from other cores. Labeling can be done by means of inscription of separate numbers on insulated cores or distinctive colors of insulation can be used. While numeric labeling the color

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Georgia

For fixed installation indoors, outdoors, in ground and in waterThe structure of conductor core is single-wire and conforms to 1or 2 class flexibility according to the standard IEC 60228:2004. On fillers of insulated sheaths a round copper wire (10-12) net and copper foil is wound, which performs protective and neutral cores function. The sections of conductor cores are: 1,5-10,0mm2 Number of conductor cores: 1,5-2,5mm2 4-5-7-10-12-14-19-24. 4-6mm2 4-5-7 10mm2 4-5Label attached to wooden drum or bundle, or in case of request of the customer with inscription on top: “JSC Sakcable” cable brand, year of manufacture. Labeling of conductor cores with colors or numbers with inscription on the surface of insulated cores.

Request for a quote

Georgia

For attachment of non-fixed and fixed current collector exploitationConductor cores with section 1,5-2,5mm2 inclusive are produced with multiple twisted wire (7-19) of 4 or 5 class flexibility, 4-70mm2 inclusive with twisted multi-core (20-140) wire of 3 and 4 class flexibility, according to standard 22483-2012. Number of cores in the cable 1, 2,3,4,5- 2.5-16 mm2 – 450M. 25-70 mm – 300M 95-240 mm – 200Min case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be producedLabel attached to wooden drum or bundle, or in case of request of the customer with inscription on top: “JSC Sakcable” cable brand, date of production. Labeling of conductive cores with colors or figures 0,1,2,3,4 with inscription on the top of insulated cores

Request for a quote

Georgia

Low-smoke, zero-halogen, flame-retardant power cable. For fixed indoor installation as well as in concrete, but not for direct burial in ground or application in waterThe aluminum cores with section 2,5-50mm2 inclusive are produced with one wire of 1 class flexibility, 70-240mm2 inclusive with twisted multi-core wires 2 class flexibility, according to standard IEK60228 : 2004. According to customer requested, it’s possible to produce cross sections 16:50 with multi-core wires. Number of cores in the cable 1,2,3,4,5in case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be producedLabel attached to wooden drum or bundle, or in case of request of the customer with inscription on top: “JSC Sakcable” cable brand, date of production. Labeling of resistance cores with colors or with numbers

Request for a quote

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For laying in ground, for overhead, into the concrete, for laying into cable channels. Using in electrical stations, in industrial equipment and in commutation systems. Working temperature on the conductor +90 0C. While laying the cables in groups, they are flame retardantThe aluminum cores with section 2,5-50mm2 inclusive are produced with one wire of 1 class flexibility, 70-240mm2 inclusive with twisted multi-core wires 2 class flexibility, according to standard IEK60228 : 2004. According to customer requested, it’s possible to produce cross sections 16:50 with multi-core wires. Number of cores in the cable 1,2,3,4,5in case of supply in bundles the construction length is agreed with the customer. In case of agreement with the customer cables of different construction lengths can be produced

Request for a quote

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For stretching in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forces. While laying the cables together, they are flame retardantThe copper cores with cross section 1,5-6mm2 inclusive are produced with 1 class flexibility,10-240mm2 are produced with twisted multi-core 2 calass flexibility according to standard 22483-2012. Number of cores in the cable 1,2,3,4,5.

Request for a quote

Georgia

For transmission and distribution of electric power at stationary devices with rated voltage 0,660kV and 1 kV frequency 50Hz. For stretching in the air where there is no danger of mechanical damage of the cable, also for laying into channels without influence of stretching forcesThe aluminum cores with section 2,5-25mm2 inclusive are produced of single wire of 1 class flexibility according to Gost standard 22483-2012. Number of cores in the cable 2,3.The aluminum cores with section 2,5-25mm2 inclusive are produced of single wire of 1 class flexibility according to Gost standard 22483-2012. Number of cores in the cable 2,3.

Request for a quote

Georgia

Low-smoke, zero-halogen, flame-retardant building wire for installation on and under plaster, in cable ducts and conduits. For indoor use onlyCopper wire cross-section 1.5-6mm2 are made with single-core with 1 class flexibility, according to the standard IEK60228:2004; Cross-section 16:35mm2 are made of twisted multi-core with 2 class flexibility, according to the standard IEC60228:2004. Cable is round. It’s possible to Production with flay constructionThe insulated cores are made of different colors, an inscription is made on the cover of the conductor “JSC Sakcable” cable brand, year of production. The wires differ by insulation color or by digits.

Request for a quote

Georgia

The industrial and power from a stationary installation inside the building and on the air. Out of buildings can be used if there is no sunlight influence on cables. Can be used on the wall or under, dry, damp and wet buildings. It can be laying into channels without influence of stretching forces. Cable has a filler, it is fire residence and flexibleThe copper cores with section 1,5-6mm2 inclusive are produced with single wire of 1 class flexibility, 10-35mm2 inclusive with twisted multi-core wires ( 7 wires) of 2 class flexibility, according to standard Gost IEC 60228 – 2004 Number of cores in the cable 1:5

Request for a quote

Georgia

For lighting and power circuits while stationary laying in electric devices, for inflexible installation in electric devices, machinery, mechanisms and industrial machines for rated voltage up to 450V (for networks 450/750V) frequency up to 400 Hz or permanent voltage 1000V. Is used for laying in empty places of steel pipes and construction structures, where there are not frequent bends of the conductor. The conductor is flame retardant.The aluminum cores with section 2,5:16mm2 inclusive are produced with one wire of 1 class flexibility, according to standard 22483 , 25-240mm2 are produced with twisted multi-core wire 2 class flexibility according to standard 22483-2012. Insulation of the conductor is made in different colors Label attached to wooden drum or bundle (coils). An inscription is made on conductor core: JSC Sakcable, cable brand, metric.