Manufacturer/producer

China

NCS-IF105 converter receives 0~20mA or 4~20mA analog signal (4 channels) and converts into fieldbus signal. NCS-FI105 converter uses digital communication technology, and makes the interface between field device and controller easier, and reduces the expense of installation and maintenance

Request for a quote

Turkey

Suitable for 95% of all applications, SVR and STK Stabilisers  not only guard against voltage fluctuations they also offer protection against all too common harmful high-energy surges, transients and voltage spikes.

Request for a quote

Italy

Verified by Europages

The robot stretch wrapping machine model. FP EASY ECO, battery-powered and automatic steering with overrunning side wheel (CE). Turning around the pallet automatically performs the film wrapping or network. Equipped with manual steering for driving forward and backward buttons, traction batteries maintenance-free gel, current transformer 24 V DC - 220 V AC, built-in charger, electric motors, three-phase inverter driving wheel height adjustment, front bumper security.Place the machine near the load to be wrapped Hook the film or the net to the load Select the wrapping program Press the start button The machine rotating around the load makes the winding and stops at end of cycle Cut the film manually Please note that the machine has a driving wheel side wheel to be placed in contact with the load, if the load surface or irregular shape must assess the suitability.

Request for a quote

Turkey

Verified by Europages

3 Phase Input / 3 Phase Output HT-C Series UPS applies advanced technology that increases performance and reliability: two high speed DSPs with completed digital control fully ensure high quality of power supply, high input power factor and low input current distortion. With in-built transformer, the HT-C is providing more safety to critical load. HT-C incluede Multi-Protection, Over-Temprature Protection with 8 Sensors, Over-Load, Battery Under Voltage, Fan Failures, Short-Circuit capabilities. HT-C taking maximum peformance from batteries with Smart Charging Control and Auto Maintenance, Greatly Extend The Battery Life. Giving perfect control to operators with Four Circuit Breakers, Friendly Operation Interface and with multi-language High-Resolution LCD Screen.

Request for a quote

China

Verified by Europages

Item: Cage Terminal for Energy Meter / LUG TERMINAL COLLAR / Terminal Lugs Material: Stainless Steel, Steel, Brass Salty Spray Test: 48~72 hours Finish: Zn-plated, Tin-plated, Nickel plated, Cleaning Application: Circuit Breaker, Energy Meter, DIN Rail Meters Mounting: be compatible with shunt type B/C, neutral connector and current transformer busbar type Rated CurrentScrewSteel Sheet Thickness (mm)Width×Height (mm²)Torque (Nm) 20AM30.83.6×1.2≥0.8 40AM41.25.5×6.5≥1.5 60~80AM51.57.5×9, 8×10≥2.5 100~120AM61.5/2.08×12≥3 ≥150AM82.010×14≥5

Request for a quote

Germany

Verified by Europages

• According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: IR 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 88 - width 105 mm - with internal residual current transformer

Request for a quote

Germany

Verified by Europages

• According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: SL 5882: 100 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts - width 35 mm - for connection of external residual current transformer, e. g. DOLD ND 5016, ND5019

Request for a quote

Germany

Verified by Europages

• According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: IL 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 880 - width 35 mm - for connection of external residual current transformer, e. g. DOLD ND 5016, ND5019

Request for a quote

China

(1)high voltage room: Rated frequency:50HZ rated voltage:10 KV Max working voltage:12 KV Rated current:630 A Transfer current:1750 A Take over current:3150 A Rated short-time withstand current:20 KA Rated peak with stand current:50 KA power-frequency withstand voltage: -line-to-line and ine-to-ground:42KV -fracture:48KV lightning impulse: -line-to-line and ine-to-ground:75KV -fracture:85KV Rated short-circuit breaking current :31.5KA transformer capacity:2500KVA (2)voltage transformer: rated voltage:10 KV rated capacity:50-600 KVA tapping range:±2×2.5%、±5% connection symbol:Yyn0、Dyn11 impedance voltage:4.5V (3)low voltage room: rated voltage:220、380 KV rated current of main circuit :50~4000 A branch circuit:5~800 A rated short-time withstand current of main circuit :50 KA rated peak with stand current of main circuit:63 KA (4)Shell: IP :IP33 Noise:≤50 dB temperature rise:10K

Request for a quote

China

Technical parameters: -Rated voltage:12KV -Rated frequency:50HZ -Rated current(the main bus bar):630A -Rated current short-term tolerance:20/4 or 25/2 (kA/s) -Rated peak when the current tolerance:50KA -Rated short-circuit making current:50KA -Rated active load breaking current:630A -Rated closed loop breaking current:630A -Rated breaking load transformer capacity:1600KVA -Rated cable charging current:10A -Rated short-circuit breaking current:31.5KA -Rated transfer current:3150A -Power frequency withstand voltage (min):phase-phase and phase-ground: 42A; isolation break:48A -Lightning shock pressure:phase-phase and phase-ground: 75KA; isolation break: 85KA

Request for a quote

France

Direction of vehicle routes for underground parking Bicolor light strips Low thickness design curve • Service life: 50,000 hours • Luminosity: 1.6 cd • Lighting color: white, orange, red, green, blue • Luminous effect: alternating strips in sequence • Terminal color: gray • Attachment: 2 M6 screws (not included) • Screw cap: 2 in zamak (included) to be glued • Low visible thickness: 19 mm • Mounting position: 1, distance between screws 86 mm • Material: zamak and TR90UV • Electrical connection: 1m 7 x 0.25mm² cable (other lengths on request) • Water resistance: IP 65 protection (IP 67 soon) • Temperature: -25°C to +60°C • Marking: laser engraving or label (on the back of the product) Electrical connection: For a buried cable implementation, use mechanical protection (sheath, conduit... etc.). Use H07RN-Ffire retardant and low smoke cable. The use of rigid cables of type U1000-R2V and others is strongly discouraged due to the risk of causing increasing moisture in the product when combined with waterproof connectors. Warning The spotlight should be powered through 12 VDC to 50 VDC transformer/voltage regulator. Do not use constant current transformer/regulator.

Request for a quote

United Kingdom

Panel & Stud termination Manufactured to BS EN61558 DESCRIPTION This range fulfills the requirements of control, safety and isolating transformers. Inrush currents and short circuit characteristics of ATL's transformers conform to up to date legislations and are compatible with all reputable manufacturers' switches breakers and magnetic release devices. All of our products are bespoke therefore voltages must be specified at enquiry stage. The transformers have protection against humidity and vibration. Our finger proof block terminals are shock proof and conform to BS EN & UL standards, other termination available please specify at enquiry stage. All of our transformers come complete with multiple footprints fixing centre's to enable a varied range of mounting configurations ref data sheet table. ** Click for more **

Request for a quote

United Kingdom

Solder tag terminated ATL range of small Solder tag transformers DESCRIPTION Small separating transformers with solder pin connections This range fulfils the requirements of control, safety and isolating transformers. Inrush currents and short circuit characteristics of ATL's transformers conform to up to date legislations and are compatible with all reputable manufacturers' switches breakers and magnetic release devices. All of our products are bespoke therefore voltages must be specified at enquiry stage. The transformers have protection against humidity and vibration. Our finger proof block terminals are shock proof and conform to BS EN & UL standards, other termination available please specify at enquiry stage. All of our transformers come complete with multiple footprints fixing centre's to enable a varied range of mounting configurations ref data sheet table. ** Click for more **

Request for a quote

United Kingdom

Panel & Stud termination Double Wound Isolation transformer - Manufactured to BS EN61558 DESCRIPTION This range fulfills the requirements of control, safety and isolating transformers. Inrush currents and short circuit characteristics of ATL's transformers conform to up to date legislations and are compatible with all reputable manufacturers' switches breakers and magnetic release devices. All of our products are bespoke therefore voltages must be specified at enquiry stage. The transformers have protection against humidity and vibration. Our finger proof block terminals are shock proof and conform to BS EN & UL standards, other termination available please specify at enquiry stage. All of our transformers come complete with multiple footprints fixing centre's to enable a varied range of mounting configurations ref data sheet table. ** Click for more **

Request for a quote

United Kingdom

Enclosed Transformer to IP21 powder coated mild steel Any configuration of switches, sockets and protection devices can be fitted on request. DESCRIPTION Our standard range of robust enclosed transformers are available to any given IP rating, material and finish. Our standard enclosures are Mild steel and finished to either Hammer grey or RAL 7032, IP21 as standard. Please note that for transformers enclosed above IP44 this data sheet is not applicable, please contact our engineers for physical dimensions. This range fulfills the requirements of control, safety and isolating transformers. Inrush currents and short circuit characteristics of ATL's transformers conform to up to date legislation and are compatible with all reputable manufacturers' switches breakers and magnetic release devices. All of our products are bespoke therefore voltages must be specified at enquiry stage. The transformers have protection against humidity and vibration. ** Click for more **

Request for a quote

United Kingdom

Shock Proof Screw terminals to UL and CSA standards Manufactured to BSEN61558 DESCRIPTION This range fulfills the requirements of control, safety and isolating transformers. Inrush currents and short circuit characteristics of ATL's transformers conform to up to date legislations and are compatible with all reputable manufacturers' switches breakers and magnetic release devices. All of our products are bespoke therefore voltages must be specified at enquiry stage. The transformers have protection against humidity and vibration. Our finger proof block terminals are shock proof and conform to BS EN & UL standards, other termination available please specify at enquiry stage. All of our transformers come complete with multiple footprints fixing centre's to enable a varied range of mounting configurations ref data sheet table. ** Click for more **

Request for a quote

United Kingdom

Transformers: 1100 kV/1000MVA Shunt reactor: 6-550 kV Current transformer: 10-550 kV Voltage transformer: 6-800 kV Lightning arrestor: 10-550 kV