Moisture content, loss on ignition – Particle size distribution – open porosity – Water absorption – Bulk density / Grain volume weight – Bulk density DIN 51081:2002-12 - Testing of oxidic raw materials and materials - Determination of mass change during annealing. DIN EN ISO 26845:2008-06 - Chemical analysis of refractory products - General requirements for wet chemical analysis, atomic absorption spectrometry (AAS) methods, atomic emission spectrometry with excitation by an inductively coupled plasma (ICP-AES). DIN EN 993-18:2002-11 - Test methods for dense shaped refractory products - Part 18: Determination of apparent density of granular materials by the water displacement method under vacuum.

Request for a quote

France

Verified by Europages

Is your product durable? To find out for sure, our technicians are now carrying out an endurance test on a railway seat. The railway seat endurance test is used to check the safety of a train seat, to test its resistance and its life span. This type of endurance test with a tri-axis bench allows us to check that the safety and comfort functions are in conformity but also to ensure that there will be no deterioration over time. To find out more about our tests visit https://lnkd.in/dngAGh2

Request for a quote

United Kingdom

We have an extensive range of product safety tests available, all within one location. Our facilities include: -Drop testing -Tumble barrel testing -Comparative Tracking Index and Proof Tracking Index -Flammability, needle flame and glow wire -Mechanical testing -Electrical testing -EMF testing and surveys. Our product safety, EMC and environmental testing facilities are all in the same location, so we will not move your product around and will not need to outsource any testing. This means all of the engineers are aware of any projects and can work together on any issues, saving the manufacturer time. We have an extensive UKAS scope, giving manufacturers assurance of reliability, accuracy and reliability. Our UKAS scope can be seen on our website and we are continually reviewing and updating the standards that we can test to. Please get in touch with our team to discuss your product safety testing requirements

Request for a quote

United Kingdom

In Canada and the USA, third-party certification of electrical products is mandatory by law. Cranage can manage your testing requirements with our partners to gain certification against International (IEC), American (UL) and Canadian (CSA) standards. The partnership advantage of working with Cranage EMC & Safety:- · Fully project managed service for Canadian, North American and CB product approvals · No need to send products away to be certified for these markets · Unlimited access to testing knowledge and compliance solutions · Factory audits and manufacturing process inspections to maintain certification · Working on your behalf with the certification lab · Local prices with excellent turnaround

Request for a quote

Switzerland

INVITRO-CONNECT GmbH: - Regulatory advice - All OECD laboratory tests - Phys-Chem / Tox / in vitro tests / Genotox / Ecotox, E-fate etc. - Personal project management - in-house toxicologists - Study monitoring - Study Summaries, IUCLID 6 - Dossier creation - MSDS etc. Benefit from an international, very well organized network: carefully selected experts, in-house toxicologists and more than 80 accredited test laboratories and service providers with over 20 years of experience in the industry. We are your competent partner for regulatory and toxicological issues, expert services, reports and all OECD laboratory tests We are also happy to be your reliable partner for your laboratory services and regulatory projects. Questions? -> contact@invitro-connect.com Your Mrs. Dr. Ute Hassmann and Your Mr. Pascal Piller

Request for a quote

United Kingdom

As Great Britain has now left the EU, we are no longer a Notified Body for EMC and are now a UK Approved Body (No.2583). However, our wholly owned Irish subsidiary, Cranage Veritas, is a Notified Body against the 2014/30/EU EMC Directive. This means they have been designated by the EU to products for conformity before being placed on the market. Cranage Veritas can work with you to assist with CE marking, ensuring your product is compliant for the relevant directives.

Request for a quote

United Kingdom

Our calibration laboratory is set-up to perform measurements of impedance and insertion loss over the frequency range 20Hz to 500MHz with automated systems to offer cost-effective results. Products manufactured by Cranage EMC Technology Limited are also backed up by extensive calibration facilities for the measurement of inductance, capacitance, and resistance. Many of our products have been independently calibrated with UKAS traceability and this has served to verify our measurement results. LISN's, PLIP's and CDN's are initially supplied calibrated with results documented according to our calibration procedures. Annual re-calibration is also provided on a standard traceability basis. You would receive a bound calibration record for each product submitted with measurement results and details of procedures used. This service is quoted inclusive of return UK carriage cost and is offered on a 5 days turnaround.

Request for a quote

United Kingdom

Our team have years of experience in several sectors and our extensive facilities include: Emissions and Immunity, Electrical Product Safety, EMF (Occupational Health and Product Safety), Environmental Protection including Salt Spray, Water and Dust Ingress and Vibration, Materials testing- including flammability, Temperature and Humidity. Our purpose built facilities are all in one location, meaning we do not outsource your testing to other companies. If your equipment is large or in-situ we are able to offer testing at your premises. Get in touch with our team to discuss your EMC, Safety and Environmental testing requirements

Request for a quote

United Kingdom

Environmental testing covers a wide range of pressures that your product may be subject to and we can simulate different climatic conditions to show weaknesses in design. Testing will allow you to demonstrate your product can be used in any conditions that it may be exposed to. Whether your product is for the food industry and will be exposed to high pressure cleaning, a light to be used outdoors or forms part of equipment that will be used in an environment where the ambient temperature is higher than in the UK, we can help. Some examples of tests are listed, but this is not an exhaustive list so please get in touch if you need to discuss your requirements: Water and Dust Ingress Salt Spray Shock and vibration Temperature and Humidity UV (Solar Radiation) simulation We are UKAS accredited for some environmental testing, giving manufacturers assurance of reliability, accuracy and consistency

Request for a quote

United Kingdom

In addition to our comprehensive testing facilities, we have a range of services available to our customers at Cranage EMC and Safety. We work with our wholly-owned, Irish subsidiary, Cranage Veritas to be able to offer a complete NRTL service- in conjunction with Met Labs. We are able to carry out testing for the American market, as well as the required factory inspections. Cranage is also a signatory of the ILAC MRA Scheme, meaning we can assist with certification for global markets such as Saudi Arabia and Australia. Together with Cranage Veritas, we can also offer a complete service for CE and UKCA marking. This includes pre-compliance and full evaluation, and completing document reviews to ensure compliance with the appropriate countries regulations. Visit our website for further details on the services that we offer and how we can help you get your product compliant for the relevant market around the world.

Request for a quote

United Kingdom

Cranage EMC and Safety is a UKAS accredited test house (No.1833). Using a UKAS lab for your testing gives manufacturers assurance of accurate, reliable and consistent test results. UKAS is the UK's Sole National Accreditation Body. We are proud of our UKAS accreditation and regularly review and update our already comprehensive UKAS scope. We offer a range of UKAS accredited testing, covering EMC, Safety, Energy Related and Mechanical testing, which can be seen on our website. If you cannot find the testing that you need, please discuss your requirements with us as we are always seeking to add to our already comprehensive UKAS scope. Get in touch with our team to discuss your UKAS accredited testing requirements.

Request for a quote

United Kingdom

Medical device testing is tightly regulated due to the potential severity of an EMC or Safety failure. The term 'medical device' covers a wide range of items and we have extensive experience in testing in this area, covering items such as prosthetic limbs, hospital beds, patient monitors, TENS machines, blood pressure monitors, to name just a few. We are UKAS accredited to test for the Medical standards IEC/EN 60601-1 and IEC/EN 60601-1-2, covering the basic safety and essential performance of medical electrical equipment. We are also UKAS accredited for the following specific medical standards: -IEC 60601-1-11 Particular requirements for medical electrical equipment and medical electrical systems in the home healthcare environment -IEC 60601-2-10 Particular requirements for the safety of nerve and muscle stimulators Using a UKAS accredited laboratory gives manufacturers assurance accuracy, reliability and consistency.

Request for a quote

Switzerland

INVITRO-CONNECT GmbH offers various test strategies without animal testing for examining skin Corrosion: - OECD 435 - Skin Corrosion : "In Vitro Membrane Barrier Test Method for Skin Corrosion" (Corrositex): The Corrositex® assay is a standardized and quantitative in vitro test developed as a replacement for the dermal corrosivity rabbit test. The Corrositex® assay is presently the only in vitro assay approved by the U.S. Department of Transportation for testing potential corrosive materials and assigning packing group categories. For more information please contact INVITRO-CONNECT GmbH for assistance in developing specialized protocols for your test materials. INVITRO-CONNECT GmbH: Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com More than 80 test laboratories - Product safety - Regulatory service - In vitro tests - All OECD tests for pharmaceuticals, chemicals, medical devices and cosmetics - Study monitoring, MSDS etc.

Request for a quote

Switzerland

- OECD 439 / Skin Irritation Test (SIT) in a Reconstructed Human Epidermis (RhE) Model - Skin Irritation in the regulatory hazard classification and labeling context is defined as the production of reversible damage to skin following a defined chemical exposure. The Skin Irritation Test (SIT) is an in vitro, non-animal test designed to identify those chemicals and mixtures capable of inducing moderate skin irritation (UN GHS Category 2 Skin Irritants1), and to discriminate UN GHS Category 2 Skin Irritants from UN GHS 3 Mild Skin Irritants as well as those not requiring classification for skin irritation potential. INVITRO-CONNECT GmbH has extensive expertise with a wide variety of reconstructed skin-based protocols. For more information please contact INVITRO-CONNECT GmbH for assistance in developing specialized protocols for your test materials. INVITRO-CONNECT GmbH: Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com

Request for a quote

Switzerland

INVITRO-CONNECT GmbH offers various test strategies without animal testing for examining Eye Irritation / Eye damage hazard assessment. From standard regulatory hazard assessments to providing information on the degree of ocular irritation, to discriminating among extremely mild eye area products, INVITRO-CONNECT’ Study Monitors take the time to understand your specific goals and apply the most relevant, cost-effective strategies to achieve them. Tests for Eye Irritation / Eye damage hazard assessment in vitro: HET-CAM Assay BCOP: OECD 437 Isolated Chicken Eye Test: OECD 438 STE / Short Time Exposure (STE, OECD 491): Ocular Irritection EpiOcular & SkinEthic HCE Reconstructed human Cornea-like Epithelium (RhCE): OECD 492 For more information please contact INVITRO-CONNECT GmbH for assistance in developing specialized protocols for your test materials. INVITRO-CONNECT GmbH: Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com

Request for a quote

Switzerland

Microbiological examinations / Microbiological tests against viruses, bacteriophages, bacteria, yeast, molds, mycobacteria and bacterial spores for disinfectants, medical devices, pharmaceutical products and cosmetics Our team of experts supports manufacturers of biocidal and medical products as well as cosmetics and pharmaceuticals scientifically in the context of approval projects. For example, we create safety assessments for cosmetics and biocompatibility assessments for medical devices. Here we focus in particular on infection prevention and wound treatment products. For more information please contact INVITRO-CONNECT GmbH for assistance in developing specialized protocols for your test materials. INVITRO-CONNECT GmbH: Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com

Request for a quote

Switzerland

INVITRO-CONNECT GmbH offers various test strategies without animal testing for examining Eye Irritation / Eye damage hazard assessment. From standard regulatory hazard assessments to providing information on the degree of ocular irritation, to discriminating among extremely mild eye area products, INVITRO-CONNECT’ Study Monitors take the time to understand your specific goals and apply the most relevant, cost-effective strategies to achieve them. Tests for Eye Irritation / Eye damage hazard assessment in vitro: HET-CAM Assay BCOP: OECD 437 Isolated Chicken Eye Test: OECD 438 STE / Short Time Exposure (STE, OECD 491): Ocular Irritection EpiOcular & SkinEthic HCE Reconstructed human Cornea-like Epithelium (RhCE): OECD 492 For more information please contact INVITRO-CONNECT GmbH for assistance in developing specialized protocols for your test materials. INVITRO-CONNECT GmbH: Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

The EP endurance test benches are used to test various components over a defined cycle for durability, e.g. temperature and pressure cycle tests. A high series quality requires precision and reliability. Operational and endurance tests are necessary in order to be able to demonstrably guarantee high quality. In the form of selection or random sampling tests, components are tested for fatigue and wear by means of load tests, for example under pressure and temperature changes. The tests are used for endurance stress testing of various materials and products with different pressure curves and temperatures. We build test benches according to your requirements: e.g. for long-term or short-term tests, under static or pulsating test conditions and depending on other factors. Present us your requirements!

Request for a quote

Germany

Testing plants in the area of bulk material processing Innovations made by Ebbecke Verfahrenstechnik To create a product exactly according to the ideas of the customer, standardized procedures are sometimes not enough. That’s why customers come from all over Europe to Ebbecke Verfahrenstechnik AG in Central Hesse – because our engineers are prepared to develop entirely new process engineering methods. With the new and further development of procedures and machines we are at the same time opening up alternative business areas for our customers. Testing and development without financial risk With all technical developments, our engineers keep the efficiency of the processes in sight. Because one thing is clear: An innovation can only prevail on the market if the development and subsequent purchase price remain within defined economic boundaries. This is where Ebbecke Verfahrenstechnik AG has been impressing for years with its pilot plants as centers of in-house development work. Toget

Request for a quote

Germany

Pressure regulator SÖHNGEN® is a precision device with an individually, step less adjustable dosage of oxygen (0-15l/min). Moreover it convinces by following features: Compact design Clear and large scale Matt chrome, sandblasted surface Connection bushing with standard thread Hand connection system without tools For all cylinder valves according to DIN 477-1;1995, no. 9 usable In accordance with UVV Oxygen BGV B7 (so far VBG 62) Certified by Federal Institute of material testing

Request for a quote

Russia

Declaration of conformity is a document that certifies conformity of the products being released (released) to the requirements of statutory documents including the technical regulations of the Customs Union. Depending on the scheme applied the products conformity assessment in the form of declaring of conformity is to be performed on the basis of applicant’s own evidence and (or) evidence obtained involving the accredited test laboratory and (or) certification authority. Declaration of conformity has equal legal force with the certificate. At the applicant’s will, if provided for by the technical regulations, declaring can be substituted with certification. declaration of conformity shall be executed on a mandatory basis, the forms of voluntary products conformity declaring do not exist

Request for a quote

Russia

Services tendered by POLYTECH Group as pertaining to carrying out necessary researches (tests) and measurements are aimed at helping you ensure compliance of the manufactured, supplied or procured products with the technical regulations of the Customs Union. We provide services at the highest level, we possess all the required certified testing equipment and calibrated instruments, we provide most accurate and consistent results. All our test engineers meet the requirements specified for qualification and work experience in the field of accreditation, they have wide knowledge in their respective areas and understanding of the applicants needs. At the applicant’s request, we carry out nondestructive examination of products visual and dimensional, ultrasonic, penetrant (dye penetrant inspection, leak detection), magnetic and others. Our laboratory has at its disposal certified specialists of II and III levels of professional qualification.

Request for a quote

Russia

Vessels designed for gases, liquefied gases, dissolved under pressure, for vapors and liquids used for fluids of groups 1 and 2 Boilers intended to produce hot water, temperature of which is over 110 °C or vapor, excessive pressure of which is over 0,05 MPa as well as directfired vessels Pipelines designed for gases, vapors and liquids used for fluids of groups 1 and 2 Equipment elements (assembly units) and components hereto that can withstand pressure Valves designed for equipment with fluids of groups 1 and 2 Indicating and safety devices Pressure chambers (except for medical singleseated ones) Protecting devices and appliances Main pipelines, intrafield and local distribution pipelines intended for transportation of gas, oil and other products except for equipment used at the pressure regulation stations or compressor stations

Request for a quote

Russia

Gas equipment designed for cooking, heating and hot water supply, including equipment as a part of combined devices Modular automatic burners (gasfired and combined) and gasequipment with modular automatic burners for cooking, heating and hot water supply Devices designed to be built in gasusing equipment and operated separately from equipment mentioned above including control, adjustment and safety appliances Steam boilers with steam pressure over 0,07MPa and hot water boilers with water temperature over 115 °С Equipment designed to be used in manufacturing processes at industrial facilities, except for the technical devices included in the list of gasusing equipment in which respect the requirements of TR CU 016/2011 are specified Equipment using gas as motor fuel Requirements of TR CU 016/2011 are set with regard to gasusing equipment listed in Annex № 1 to the Regulations.

Request for a quote

Russia

Machines and (or) equipment including those used at hazardous industrial facilities, for which types of hazard have been detected and identified, the requirements for elimination and reduction of which are set out according to the Annexes № 1 and № 2 to the regulations. Annexes № 1 and № 2 to the regulations contain basic and supplementary safety requirements for machines and equipment. Used machines and (or) equipment, or those produced for own manufacturers’ needs Component and spare parts to machines used for repair (maintenance) of machines and (or) equipment Machines and (or) equipment meant to maintain integrity and stability of communication networks performance and use of RF spectrum Machines and (or) equipment used for medical purposes and used in direct contact with a patient (Xray, diagnostic, therapeutic, orthopedic, dental, surgical equipment) Machines and (or) equipment specially designed for nuclear energy use area.

Request for a quote

Belgium

How practically feasible or realistic is an idea? Sirris can help you find out, and not just by offering advice. All the innovative solutions we develop together with you are also put to the test in an industrial setting, either on your behalf or in conjunction with you. Our high-tech infrastructure will always enable you to find out exactly where you stand. A few examples of our infrastructure A metal machining centre, guaranteeing micron precision Europe's largest climate chamber Cobots deployed in a flexible, robotised, machining cell Europe's most highly diversified additive manufacturing machine park Hybrid PVD or HiPIMS and aerosol jet printing Microproduction (machining, EDM, injection moulding , etc.). An application lab for Incremental Sheet Forming (ISF) Testing laboratories for materials & products analysis...

Request for a quote