• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • pad printing

Results for

Pad printing - Import export

France

France

Pad printing allows a precise application, even on irregular surfaces, and also a wide choice of colors.

Request for a quote

France

Verified by Europages

Bold spinner, antistress ball pen with push-up mechanism and design with accessories in silver color and a solid finishing body in bright colors. Especially designed for pad printing in clip and body. Jumbo cartridge and blue ink.

Request for a quote

France

Verified by Europages

Multifunction ball pen with push-up mechanism in bold colors and dual-function clip especially designed to function as a holder for mobile devices and also as a screen cleaner. With body in metallic finish, especially designed for pad printing and black ink. Black Ink. Screen Cleaner Included

Request for a quote

France

Verified by Europages

Antibacterial ball pen with push-up mechanism. Monochromatic design in a wide range of bright tones with a glossy finish, especially designed for pad printing. Blue ink refill. Products with antibacterial treatments are able to drastically reduce the bacterial levels present on the surfaces of the materials, thanks to the addition of permanent static microbial agents, with high effectiveness in inhibiting and preventing bacterial contamination. Item according to the ISO 22196 standard, which determines the antibacterial activity in plastic materials and non-porous surfaces. This allows us to know the effectiveness of microbial inhibition that additives have on treated objects by means of a quantitave evaluation.

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 420 years Max. activation distance: 9 mm, 1 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.4A max / 24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (ref. + OX) Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm cord with M12 connector (UL20549 PUR) (ref. + MKT) Water resistance: IP 67/68 or IP 69K stainless steel version (requires cable input protection) Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Ultra-compact format Automatic RS485 networking with M12 connector output Deferral of all M12 connector outputs Indicator: LED indicates activation of the network Attachment: 4 M3 screws (with washers) Mounting position: 1 Material: POLYCARBONATE Electrical connection: 8 M12 connectors Sealing: IP 54 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability Options: - Software for real-time monitoring with openings traceability via PC (ref MDB13-SP.) - Software programming of badges and network configuration (ref MDB13-PR.) - Automatic network connection (LKS485): up to 8 cascading boxes and 4 readers per box or 32 readers. Individual contact outputs on each box - badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control and traceability

Request for a quote

France

RFID sensor with 16 million codes Lock control and "burglar" alarm Supervision, traceability via PC, RS485 network and output contacts Life cycle: 20 years Max activation distance: up to 45 mm Contact/diagnostics: 1 x 1.8A PNP timed 5s/2 x 100mA PNP Alarm 1 (120s failure to close) and 2 (30s breaking open) Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 1 Material: POLYCARBONATE Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability Options: - Software for real-time monitoring with openings traceability via PC (ref MDB13-SP.) - Software programming of badges and network configuration (ref MDB13-PR.) - Automatic network connection (LKS485): up to 8 cascading boxes and 4 readers per box or 32 readers. Individual contact outputs on each box - badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control and traceability

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category: up to 4 (EN 954-1) with AWAX controller Time to dangerous failure: MTTFd = 40 years Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 50mA/30V and 1 x 50mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -30 °C to +50 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability Certificate: E2 10R-04 14053 (UTAC) ISO 7637-2 (Pulse 1, 2a, 2b, 3a, 3b, 4)

Request for a quote

France

Sensor contactless technology, low simultaneity ATEX Zone 2 and 22 category 3GD No power Atex safety EN 60079-15 EN 61241-1 Machine Safety Level of performance with AWAX26XXL-EEX3 controller: up to PL = e in accordance with EN ISO 13849-1 Cycle before dangerous failure: B10d = 62,500 Max. activation distance: 17 mm, 5 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/24V redundant 1xNF/50mA/24V redundant parallel Overcurrent: 500mA for 2s Shock resistance: 50 G. Vibrations: 30 G Detection encoding: mono-code Indicators: no Reset: automatic Total number of connectable sensors in series: 30 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Marking: pad printing + serial no. for traceability Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -5°C to +80°C.

Request for a quote

France

RFID sensor with 16 million codes Category 3 total security management without an external controller Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 (EN 954-1) Cycle after dangerous failure: B10d = 2000000 at 2 Amps Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 2A/48V and 1 x 400mA PNP auxiliary Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm PUR cable with M12 connector (base + MKT) Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Max activation distance: up to 24 mm Security contact/diagnostics: 2 x 400mA and 1 x 200mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -25 °C to +70 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability

Request for a quote

France

RFID sensor with 16 million codes Lock control and two alarm levels Programmable code through auto-learning (no software or PC) Switching cycle: B10 = 1 million Max activation distance: up to 25 mm Contact/diagnostics: 1 x 1.8A PNP timed 5s/2 x 200m APNP Alarm 1 (120s failure to close) and 2 (30s breaking open) Duration of alarms editable upon request (XR530P, P1 ... P10) Detection encoding: 16 million Indicator: LED indicates code recognition Optional erasing card to reassign new codes Encoding of geographic location: (base + E1 to E10) Reset : automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m (UL2464 PVC) Sealing: IP 67 Temperature: -25 °C to +70 °C. Marking: pad printing + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications • Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with an AWAX controller • Time before dangerous failure: MTTFd = 334 years • Max. activation distance: 10 mm, 2 mm hysteresis • Safety contacts/diagnostics: 2 x NO 0.8A max / redundant 24V / 1xcontact PNP 250mA • Detection encoding: mono-code inviolable • Indicator: LED indicates code recognition • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 78S-98S, 78SMKT, 78SMKT130 versions: 2 (double wall brackets) • Mounting position: 78SM12 and 98SM12 versions: 1 • Material: 78S-98S, 78SMKT, 78SMKT130: PA6 or INOX316L (ANATOM78S-OX or ANATOM78S-OX-MKT) • Matierial for 78SM12, 78SESM12 and 98SM12 : polycarbonate (PC) • Electrical Connection: 3, 6, 12m cable (78S/98S) or 50cm cord with M12 connector (ref. + MKT) or 130cm cord with M12 connector (ref. + MKT130) or M12 metal (ref. + M12) • Water resistance: IP 67/68 (PA6, PC) or IP 69K with stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial no., PC pad printing + serial no., INOX316L laser engraving with mechanically punched serial no. for permanent traceability • Certification: UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209) (Not applicable for versions MKT and M12)

Request for a quote

France

250 VAC lighting switch in the premises 24 VDC machine control Request for stop/opening for public transport • Number of cycles: 100 million at 200 mA • Standard activation distance: 0 mm • Electrical contact KB100A: 1 RT 1700 VA/250V • Electrical contact KB100M: 1 NO, 1 NO+1NF, 8A/250V • Electrical contact KB100M: 1 PNP NO, 400mA/24V • Selectable features KB100A and KB100M: bistable, monostable, deferred stop (90s timer), delayed start (350ms). Other value on request. ▪ Function details: • ON/ON = momentary with fraud protection The action is canceled if the finger or organic material is present longer than 5s ON/OFF = bistable. One pulse switches the contacts and another pulse places the contacts at rest ON/duration/OFF = delayed stop 90s "timer" feature (other value on request) Offset ON = delayed start. To confirm the request the button must be held for 350ms (other values on request) ▪ Indication by LED ring offset effect: KB100A: white or amber color (other on request) KB100M: green and red color KB100TR: green and red color ◦ Bicolor LED indication by external control: version "OL" • Attachment 1: recessed box for plaster panel (2 D3 screws) • Attachment 2: panel by invisible screwing (2 to 6 D3 screws) • Material: TR90UV • Food contact: yes • Resistance to washing: yes • Anti-vandalism: yes • Electrical connection: 1m cable or 1.5mm² connector without screws • Water resistance: IP 67 with peripheral silicone seal • Temperature: -25°C to +60°C • Marking: pad printing on the trim of some models Silkscreen reference on the back of the product

Request for a quote

France

Contactless encoded electronic sensor with relay Up to 8 zone differentiation codes Safety contacts 2A / 250V • Level of performance without an external controller: PL = c • Level of performance with AWAX controller: up to PL = e • Safety category without an external controller: 1 • Cycle before dangerous failure: B10d = 2,000,000 at 2A • Max. activation distance 3SSR24V/5SSR24BX/5SSR24BX-US: 8 mm, 2 mm hysteresis • Max. activation distance 2SSR24V/2SSR24BX: 4 mm, 2 mm hysteresis • Safety contacts/diagnostics 3SSR24V: 1 x NO 2A/250V / 1 x NF 2A/250V auxiliary • Security contacts/diagnostics 5SSR24BX and 5SSR24BX-US: 2 x NO 2A/250V / 1 x PNP NF 250mA auxiliary (24V) • Security contacts 2SSR24V: 2 x NO 2A/250V • Security contacts 2SSR24BX: 1 x NO 2A/250V and 1 x NF 2A/250V • Detection encoding 3SSR24V, 5SSR24BX/5SSR24BX-US: single inviolable code • Detection encoding 2SSR24V and 2SSR24BX: 8 inviolable codes • Indicators 2SSR24V, 2SSR24BX, 3SSR24V and 5SSR24BX: Red LED indicating code absence (not transmitter) • Indicator 5SSR24BX-US: Two-color red/green LED • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 2 (double wall brackets) • Matierial PA6: 2SSR24V, 2SSR24BX, 3SSR24V, 5SSR24BX, 5SSR24BX-MKT and 5SSR24BX-US • Material INOX 316L mirror polished: 5SSR24BX-OX and 5SSR24BX-OX-MKT • Electrical Connection: 3, 6, 12m cable or 50cm cord with M12 connector (UL20549 PUR) for5SSR24BX-OX and 5SSR24BX-OX-MKT • Water resistance: IP 67/68 (PA6) or IP 69Kwith stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle after dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Security contacts / diagnostics AMX5 / AMX5CM12: 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary Security contacts AMX4: 2 x NO 2A/48V redundant Security contacts / diagnostics AMX3: 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ⇥or PC (AMX5CM12) Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12) Water resistance: IP 67/68 (PA6 / PC) or IP 69K with stainless steel - new generation Temperature: -25°C to +60°C Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12 UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business