• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • heating ovens

Results for

Heating ovens - Import export

Germany

Germany

Verified by Europages

The specimen is cyclically loaded in a cold-heat oven to freely programmed load follow with torque. Rotation angle and temperature are documented with. Applicationfield Automotive industry; Optimization of the granular mixture of rubber elements of a window motor.

Request for a quote

Germany

Verified by Europages

Raytek GS150 thermal imaging systems enable automated quality control in glass bending, forming, annealing, and tempering processes. The GS150LE variant is especially designed for Low-E (low emissivity) glass / one-side coated flat glass. It features automatic emissivity correction. The systems are based on the Raytek MP150 infrared line scanner, which has a max. resolution of 1024 points per line, a max. 150 Hz scanning frequency, and an up to 90° wide field of view. SYSTEM PROPERTIES • Automated temperature monitoring • Visualization on PC • Ethernet TCP/IP interface integrated in the line scanning system • PC-independent alarm output • PC-independent analog outputs 3 x 4 – 20mA BENEFITS • Improve profitability and product quality • Reduce set-up time • Detect defects quickly • Automate quality monitoring for ISO9000 • Reduce scrap • Efficiently manage the heat balance in the oven • Automatically adjust the emissivity value when changing glass types or coatings

Request for a quote

Germany

In-line conveyor ovens: Pallets pass through the oven one after the other. Automatic batch ovens: The oven is charged with pallets while kept at a temperature below the gelation temperature. After the last pallet has been loaded, the temperature cycle is started for the whole lot. The oven is emptied in a rapid process after the complete temperature profile has been run through. Stack ovens: Pallets are loaded into the oven. When each row has been filled, all the rows of pallets are lifted up by one level. When one row of pallets has reached the uppermost position of a temperature range, it is pushed into the next temperature zone and from here is lowered down in fixed time cycles and unloaded. Serpentine conveyor ovens: Pallets are loaded into the oven in fixed time cycles and pass through the individual temperature zones.

Request for a quote

Germany

Plunger Force Adjustment Video Tutorial ILS glass syringes are manufactured to exacting standards and are quality tested to meet or exceed our minimum performance specifications for accuracy and precision. Our testing methods are in accordance GLP protocols and utilize equipment that is traceable to NIST standards. Copies of actual test result are available upon request. Syringe use: - eliminate the carry over between the samples. Rinse the syringe with the to be examined liquid 10-20 times. Wash the syringe and discard the first 2 -3 washes. - for injection overfill the microlitersyringe. Press the plunger until the accurate volume. Syringe cleaning - pull the piston out of the glass body of the microsyringe - rinse inside the glass body with detergents (in the final rinsing cycle it is best to use a low boiling point, solvent or alcohol) - dry the glass body by air flow, e.g. with a vacuum pump CAUTION: DO NOT IMMERSE THE MICROSYRINGE IN THE SOLVENT: THE GLUE PARTS CAN BE SOLVED. Needle blocked: - use the cleaning wires from ILS you find a wide range at www.microsyringes.com Plunger with seal - if you want reduce the plunger force, heat the assembled syringe in oven at 60°C 15 minutes - Silicone or other lubricants that are compatible with your sample may also be used to wet the plunger tips CAUTION: RUNNING A TEFLON-TIPPED PLUNGER DRY MAY CAUSE THE PTFE TO SHRED OR PULL LOOSE FROM THE PLUNGER ROD, RESULTING IN LEAKS. Plunger Tip ss*=stainless steel (N- Series) -clean the plunger in an ultra sonic bath - wipe the piston with a fibre-free cloth (i.e. no paper towel) Plunger of zero dead volume syringes (T- Series) - loose the nut before pull out or insert the plunger - wipe the piston with a fibre-free cloth (i.e. not paper towel)

Germany

Device details: ■ 2 in 1: device contains the Hot Set Test as well as the Heat Pressure Test ■ Robust and compact set including the device and an equipment case ■ Possibility to attach a thermometer directly near the sample ■ Measurement according to the standards IEC EN 60811-507 (Hot Set Test) and IEC EN 60811-508 (Heat Pressure Test) regarding sample attachment and weight attachment ■ Precise choice of weights due to practical containers ■ Simultaneous measurement of up to 3 samples Optional - Hot Set Test complete ■ Sample rack for heat pressure and heat elongation test ■ Laser gauge ■ Thermal heat oven UN55 Size (WxLxH): 585 x 514 x 784 mm (23 x 20.2 x 30.9“) Weight: 57 kg (125.6 lbs) Volumen: 53 l Air exchange rate: 8-20x ■ Thermal heat oven UN110 Size (WxLxH): 745 x 584 x 864 mm (29 x 23 x 34“) Weight: 74 kg (163 lbs) Volumen: 108 l Air exchange rate: 8-20x

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business