BOPP & REUTHER MESSTECHNIK GMBH

Germany

Factory icon Manufacturer/ Producer

BOPP & REUTHER MESSTECHNIK GMBH
Web icon
25 Products

Germany

Mass flow meters serve to measure fluids and gases. The mass flow meter utilises the Coriolis force for flow measurement. The omega loop has proven itself particularly suitable for this process. The measuring tubes, which are bent to omega loops, are completed by two measuring bars and vertically secured torsion bars to create a harmonious oscillator. This carefully balanced and robust design has an extremely low power input. The frequency of the system essentially depends on the mass of the bars and the elasticity module of the torsion bars. Two electromagnetic coils set the system in motion. As soon as liquid or gas flows through the oscillating omega tubes, the resultant Coriolis force causes displacement of the tubes. The comparative relationship is established and the change in displacement is proportional to the mass flow. Application • i.a. custody transfer for mineral oils, bitumen and other viscous media

Request for a quote

Germany

Leves complement ideally to flow measurements, since each flow is coming from a container or is pumped into a tank or container. For this the level information is extremely important because through these pumps and valves can be controlled, so that the flow can be measured with high reliability. In case of emptying tanks, the pump power can be reduced, so that the risk of air in the pipes is reduced. This in turn would affect the measurement. During tank filling can by throttling the power of the pump a overfilling be avoided so that the full capacity of a tank can be exploited. The level measurement in combination with the flow measurement complement each other ideally, if the measured information are processed together and evaluated. The plant availability is held high, because in case of failure or maintenance of a measurement, the other still works. Energy optimized, high-frequency electromagnetic impulses, generated by the electronics, are propagated along the probe (single rod..

Request for a quote

Germany

The operation of the Oriflow Compact Orifice is based on the measurement of differential pressure, which is created across that section of a pipe where its cross section is reduced. This is then taken as a measure for the flow. Reliability • already over 2,000 units in operation • extremely rugged and stable measuring instrument • suited for extreme applications Special features • dry calibration is possible • highly reproducible results • easy to install without differential pressure lines Flexibility • DN 15 to DN1000 • 0,4 bis 20000 m 3/h • -40°C to +400°C (depending on model) • to PN 40 (higher upon request) • current output with HART ® • electronical local display

Request for a quote

Germany

Application To avoid measurement errors and damage by foreign objects carried in the medium. Reliability Complete emptiying of conical design and drain plug at the lowest point of the filter (filters in cast). Special features Low pressure drop due to large filter surface area (up to 16 times the pipe crosss-section) Flexibility • DN15 to DN400 • -200 °C to +300 °C • to 3.000 m³/h • to PN100 • different materials

Request for a quote

Germany

Centrifugal gas separator are among the best components in the protection of your flow measurement accuracy, both custody transfer applications as well as in everyday application process. Application For avoiding measuring errors and damage caused by foreign particles contained in the medium. Reliability • maintenance-free • complete emptying via outlet socket Special features • with automatic float-dearation device, level probe and controled magnatic valve or defined return to the process (orifice) • mandatory for fiscal metering with pump operation in Germany • Bopp & Reuther Messtechnik Centrifugal Gas Separators possess the EWG design approval and are approved for EWG primery approval for fiscal metering Flexibility • DN 25 to 400 • up to 20 mPa ·s • up to 25.000 l/min • up to PN 50

Request for a quote

Germany

Technical specifications • inner threads G1/4” ISO 228, flange DN 10 PN 40, sterile screw joints according toDIN 405 PN 16 • accuracy ± 0,1 kg/m³ • reproducibility 0,05 kg/m³ • operating temperature according to design -40°Cto +150°C • according to design admitted for custody transfer Accessoires • electronical transmitter • preamplifire • strainer • gas separator • processing peripherals

Request for a quote

Germany

Technical specifications • Swagelok-screw joints, flange DN 15 PN 40, milk threads according to DIN 11851 PN 10 • accuracy ± 0,2 kg/m³ • reproducibility 0,05 kg/m³ • operating temperature according to design -40°C to +210°C Accessoires Accessoires • electronical transmitter • pre-amplifire • strainer • gas separator • processing peripherals

Request for a quote

Germany

Technical specifications • flange DN 25 / 50 PN 40 • accuracy ± 0,2 kg/m³ • reproducibility 0,05 kg/m³ • operating temperature according to design -40°C to +150°C Accessoires • electronical transmitter • pre-amplifire • strainer • gas separator • processing peripherals

Request for a quote

Germany

For applications in laboratory, medical and engineering, where limited space, monitoring fluid quality and costs play an important role, they provide an ideal, previously not achievable solution. Technical specifications • hose connector • accuracy ± 1 kg/m³ • reproducibility 0,1 kg/m³ • operating temperature 0°C to +70°C • measuring range density 500-1500 kg/m³ • measuring flow 1-6 l/min Accessoires • strainer • gas separator • plug

Request for a quote

Germany

Critical measuring tasks require specific density measuring instruments adapted to the individual requirements of our customers. For this purpose we offer tailor-made solutions according to the varying needs of our customers. Technical specifications • models approved for fiscal metering • high pressure models • high temperature models (up to 210 °C) • high precision models meeting specific customer requirements • models whose electronic components may be mounted separately (e.g. for mounting on walls or pipes) • density measuring units with protective housing • special models with flow rate up to 100 l/m (higher flow rate on request) Density measuring unit built into a protective housing incorporating a sight glass optionally available with • pump • flow monitoring • connection to rinsing equipment • strainer • gas detector • heating • equipment for base or wall mounting Advantages • complete solution from one source

Request for a quote

Domain icon Manufacturer/ Producer

BOPP & REUTHER MESSTECHNIK GMBH

Am Neuen Rheinhafen 4

67346 Speyer - Germany

VAT No.
Contact
Office Building Outline icon
A page for your business
Can you see this? Your potential clients will too. Join us now so you too can be visible on europages

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free