COMITRONIC BTI

France

Factory icon Manufacturer/ Producer

Web icon
58 Products

France

Compact 22.5 mm format Six Class A EN 50205 power contacts Removable terminals Cycle before dangerous failure: B10d=100,000 at 5A Max. closing time for NO contact: < 15ms (rebounds included) Duration of rebounds for NO contact: < 4ms Max. closing time for NF contact: < 16ms (rebounds included) Duration of rebounds for NF contact: < 13ms Protection severing wires: yes (opening of NO contacts) Safety contacts: 4x NO 8A/250V / 2x NF 8A/250V Indicators: 2 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Compact 45 mm format Two position key switch: free and captive Removable terminals Level of performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 4x NO 8A/250V redundant / 1x NF redundant in series (test) and 8A/250V parallel (information) Indicators: 2 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Add 4 power safety lines at 8A/250V with a safety PLC or control box without loss of Safety Class Compact format 22.5 mm/removable terminals Level of performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 4x NO 8A/250V redundant / 1x NF redundant in series (test) and 8A/250V parallel (information) C4SX indicators: 2 LEDs C5SX indicators: 2 LEDs Reset: automatic Number of inputs: 1 (C4SX) and 2 (C5SX) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Door unlocking control on motor shutdown Detection of asynchronous motors stoppage without external sensor Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Time before dangerous failure: MTTFd = 100 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: approx. 2 to 7s adjustable at front Persistence: approx. 20 mV to 700 mV adjustable front Motor power: up to 3x690 VAC Protection for severed wires: yes Protection against disconnection of motor coiling: yes Safety contacts: 3x NO 8A/250V redundant Diagnostics: 1x NF 8A/250V redundant parallel. 1 PNP "OK" output indicating motor coiling presence. 1 PNP "ERROR" output indicating a synchronization malfunction. 1 "RS" system reset input. Indicators: 3 LEDs for diagnostics Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management in a compact 22.5 mm format Mono or two-channel with wiring. "Low consumption" Inputs Removable terminals Performance level with AWAX controller: PL = d Safety category: 3 (two-channel) Safety Integrity Level: SIL 2 Time before dangerous failure: MTTFd = 240 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 2x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant + 1x NO static 400 mA Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Suitable for groove profiles and single or double doors Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 334 years Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xNF (78S) or 1 x NO (98S) 250mA Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 2 M12 metal bases for instant serial connection Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 7 mm, 1 mm hysteresis, rotation ± 30° Safety contacts/diagnostics: 2 x NO 1A/24V redundant and 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M4 screws not included; anti-rotation lugs provided Mounting position: 1 (4 x paste on screw-caps provided) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Temperature: -30°C to +110°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

Domain icon Manufacturer/ Producer

COMITRONIC BTI

14 Rue Pierre Paul de Riquet

33610 Canéjan - France

VAT No.
Contact
Office Building Outline icon
A page for your business