Germany
Manufacturer/ Producer
Germany
Thermowells are generally used where they remain in the measured medium and only the temperature sensor is to be replaced or retrofitted or the measured media must not touch the temperature sensor directly. Thermowells also provide protection against mechanical stress. Labom thermowells are manufactured according to national standards or to customer specifications. The corresponding Labom dial thermometers and temperature measuring transmitters are optimally adapted to them in metrological terms.
Request for a quoteGermany
Pressure gauge NG 63/100 in hygienic design for diaphragm seal operation, types series BH8: Features: High quality case NS 63/100 in hygienic design as per EHEDG recommendation Degree of protection IP 65 Accuracy class 1.6/1.0 per EN 837-1 Flush mounted diaphragm Small temperature error by means of reduced-volume measuring element Options Neck tube and diaphragm seal in a one-piece design, optionally complete case including neck tube and diaphragm seal in an hygienic version available (Ra < 0.76 µm as per ASME BPE SF3 / EHEDG Doc. 8) Material certificate per EN 10204 Calibration certificate per EN 10204 Damping of movement Precision scale Autoclavable EAC declaration (upon request)
Request for a quoteGermany
High-resolution graphic display with backlight Intuitive 4-button operation Comprehensive parameterising functions Comprehensive simulation and diagnostic functions Quick access to device data Development according to SIL2 Nominal range 0.25 bar to 40 bar Turndown up to100:1 Measuring rate up to 100 Hz Accuracy 0.1 % Output signal 4…20 mA with HART® protocol Configuration memory Digital communication via PDM, FDT/DTM, 375/475 Field Communicator Output functions: linear, invers, square root, table function Table function with up to 64 support points Stainless steel case in hygienic design, degree of protection IP 65/67 Media temperature up to 160 ° C Wetted parts stainless steel Case design: - process connection bottom - process connection back Various hygienic process connections Approved according to NAMUR 95 EAC declaration (upon request)
Request for a quoteGermany
Pressure transmitter with diaphragm seal technology for the measuring of relative and absolute pressures of gases, vapors and liquids Stainless steel case in sturdy design, degree of protection IP 65/67 Accuracy 0.1 % High-resolution graphic display with Intuitive 4-button operation and backlight Comprehensive parameterising functions Comprehensive simulation and diagnostic functions Quick access to device data Development according to SIL2 Nominal range 0,25 bar to 400 bar Turndown up to 100:1 Measuring rate up to 100 Hz Output signal 4…20 mA with HART® protocol Configuration memory Digital communication via PDM, FDT/DTM, 375/475 Field Communicator Output functions: linear, invers, square root, table function with up to 64 support points Media temperature -40…400 °C Case design process connection bottom Case design process connection back Various process connections Approved according to NAMUR 95 EAC declaration (upon request)
Request for a quoteGermany
The resistance thermometer in clamp-on technology is used for temperature sensing and process control, mainly for sterile applications in the food and pharmaceutical industries.The resistance thermometer can be quickly and easily fitted to all existing pipework. There are no changes necessary to the piping and no welding required. The resistance thermometer can be supplied with a built-in transmitter.
Request for a quoteGermany
Analogue pressure and differential pressure transmitter series Features: Analogue pressure and differential pressure in numerous designs Proven reliability in numerous designs and processes Piezoresistive measuring system or thin film Measuring system high overload protected Wetted parts of stainless steel Degree of protection IP 65 Options: Explosion protection for gases and dust GL (Germanischer Lloyd) certificated (CB1/CE1 only) Degree of protection IP 67 Classification per SIL2 (COMPACT)
Request for a quoteGermany
Pressure transmitter COMPACT Features: Measuring ranges 0…250 mbar up to 0…100 bar Linearity error including hysteresis <+ 0.2 % f.s. Piezoresistive measuring system Hygienic design according to EHEDG, FDA and GMP recommendations Material and surface quality according to the hygienic requirements Wetted parts of stainless steel; completely welded Stainless steel housing as standard or field housing Degree of protection IP 65, IP 67 option Output signal: 4…20 mA Process temperature up to 200 °C Options: Explosion protection for gases Classification per SIL 2 Inspection certificate: material certificate as per DIN EN 10204-3.1
Request for a quoteGermany
The digital differential pressure transmitter PASCAL Ci4 Delta P has been specially designed for the mounting of diaphragm seals with a volume reduced differential pressure chamber. Due to this design the transmitter is suitable for various applications, e.g. for the level measurement of pressure vessels.
Request for a quoteGermany
The temperature transmitter PA2530 with mit IO-Link is suitable for hygienic temperature measurement in connection with the following resistance thermometers ■ LABOM MiniTherm, Type series GA27 (see data sheet T4-014, T4-015 and T4-017) ■ LABOM Clamp-on, Type series GA2610 (see data sheet T4-028) Due to its compact design the transmitter fulfils the hygienic requirements of plant and machinery engineering.
Request for a quoteGermany
Pressure transmitter/Pressure switch PASCAL CSfor general applications, Type series CS2100 Multifunctional pressure transmitter/pressure switch Degree of protection IP 65 4 digit LED display, can be mirror-imaged by 180° Indication module can be turned through 300° Measuring ranges 0…100 mbar to 0…40 bar rel., 0…1 bar to 0…6 bar abs, High pressure 0…60 bar to 0…400 bar Output signal 4…20 mA, 2-wire technology Accuracy: ≤ 0.2 % Easy to program locally (as per VDMA standard) Galvanic isolation between transmitter and switching outputs Various process connections Options 2 floating contacts Switching contacts with high switching current (1A) Inspection certificates - material certificate per DIN EN 10204-3.1 - calibration certificate per DIN EN 10204-3.1 Electrical connection rotatable by 300° Degree of protection IP 67
Request for a quoteManufacturer/ Producer
Im Gewerbepark 13
27798 Hude - Germany
Germany
The T610 is a handheld measuring instrument from the Trotec MultiMeasure family, used for quick non-destructive moisture measurement up to 300 mm. Another advantage of the process, aside from the measuring depth, is its independence from the level of salt content in the material. This creates no dissimilarity to the microwave technique, whether it is an older or a new building being gauged. Since the unit’s screen can show two values, for purposes of results evaluation, a function value can be indicated at the same time as the present measured value, if needed. The T610 moisture meter can be linked to a PC through a USB cable. Due to the MultiMeasure Studio Software, the gauged values of the device can be transported online and in real time to the PC. A few practical benefits: German industrial design in robust, premium two-component construction with IP54 type of protection
Request for a quoteGermany
Overpressure or underpressure - Different pressure and measuring ranges - Various operating languages - Optionally with ProfiNet interface and USB interface - Robust, durable design
Request for a quoteGermany
The SENSORMASTER 9163 covers a wide range of applications in which process values need to be measured, displayed, analyzed and transferred to higher-level control systems. Typical applications include measuring geometric values in production, for instance differential measurements, or testing material properties in the laboratory. The measured values can be transferred via USB, RS232 or analog output. Features: — For force, pressure or torque measurements using strain gauge sensors — For position or angle measurement using potentiometric or DC/DC sensors — For temperature measurement using Pt 100 sensors or thermocouples — Optional multi-channel model — Optional Profibus or serial interface — 0.1 % measurement accuracy plus sensor-specific linearization — Range of mathematical functions (e.g. differential measurement) — OK/NOK feedback on multi color display and via 4 alarm limit outputs — High sampling rate (500/sec.)
Request for a quoteGermany
Based on its specifications, this device can be used in various applications. It is especially suitable for resistance measurement on insulating materials such as e.g. cable insulations, foils, textiles, surfaces, insulating liquids,etc. With a test voltage of 45 V, 100 V, 250 V and 500 V the device fulfi ls most test specifi cations such as e.g. DIN 51953, 53482 and 54345. The guard switching allows single resistance measurements in a triangle wiring. This could be e.g. a two line cable with common shield or the measurement of insulating materials on a guardring measurement cell. The selection of the measurement range is done manually or automatically. Fast subsequent measurements can be realized by the internal limit value indicator. When the measured value exceeds the limit the limit value indicator switches and activates a potential-free relay output. The megohmmeter RESISTOMAT® model 24508 is the right instrument for its use in laboratory as well as in industrial applications.