• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • current relays

Results for

Current relays - Import export

Turkey

Verified by Europages

Germany

Verified by Europages

STOL®78 is a CuMg alloy for connectors in automotive, electrical and electronic applications. Thanks to the combination of high electrical conductivity with high strength and good relaxation resistance, this alloy is particularly suitable for relays, current carrying springs, bus bars and fuse boxes with resilient functions.

Request for a quote

Turkey

Verified by Europages

Design: Ergonomic, service and drip tray are integrated with the machine body. Control System: Smart Plus control panel (programming each day separately - electricity / on / off / temperature control / wate level control / maintenance period determination / working mode / real time clock / day no. Temperature Control : Digital temperature sensor Temperature Display: Digital display Water System: SWS (Smart water system - can get water from the network or from the bottle with a pump). Resistance Power: 2+2 KW (RiCA) Natural gas capacity: 5.4 KW/h Water Reservoir Drain System : Yes Water Tank Structure: Weldless plastered stainless tank Water Tank Material: Stainless 304 L DDQ 1, 2 mm Electrical Safety: 25 mA leakage current relay Component Safety: 25 A Contactor Thermal Insulation: Ceramic fiber blanket Hot water outlet tap: Yes On-Off Switch: Yes Drainer Discharge System: Yes Foot: 4cm foot Water Capacity: 30+30 lt double water tank Ignition System: Battery operated lighter

Request for a quote

Turkey

Verified by Europages

Design: Ergonomic, service and drip tray are integrated with the machine body. Control System: Smart Plus control panel (programming each day separately - electricity / on / off / temperature control / wate level control / maintenance period determination / working mode / real time clock / day no. Temperature Control : Digital temperature sensor Temperature Display: Digital display Water System: SWS (Smart water system - can get water from the network or from the bottle with a pump). Resistance Power: 2+2 KW (RiCA) Natural gas capacity: 5.4 KW/h Water Reservoir Drain System : Yes Water Tank Structure: Weldless plastered stainless tank Water Tank Material: Stainless 304 L DDQ 1, 2 mm Electrical Safety: 25 mA leakage current relay Component Safety: 25 A Contactor Thermal Insulation: Ceramic fiber blanket Hot water outlet tap: Yes On-Off Switch: Yes Drainer Discharge System: Yes Foot: 4cm foot Water Capacity: 30+30 lt double water tank Ignition System: Battery operated lighter

Request for a quote

Turkey

Verified by Europages

Design: Ergonomic, service and drip tray are integrated with the machine body. Control System: Smart Plus control panel (programming each day separately - electricity / on / off / temperature control / wate level control / maintenance period determination / working mode / real time clock / day no. Temperature Control : Digital temperature sensor Temperature Display: Digital display Water System: SWS (Smart water system - can get water from the network or from the bottle with a pump). Resistance Power: 3 KW (RiCA) Water Reservoir Drain System : Yes Water Tank Structure: Weldless plastered stainless tank Water Tank Material: Stainless 304 L DDQ 1, 2 mm Electrical Safety: 25 mA leakage current relay Component Safety: 25 A Contactor Thermal Insulation: Ceramic fiber blanket Hot water outlet tap: Yes On-Off Switch: Yes Drainer Discharge System: Yes Foot: 4cm Foot Water Capacity: 30 liters Maintenance Schedule Determination: Yes Clock, Real Time: Yes

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Japan

Glass-enclosed contacts are not affected by the external atmosphere, and solve the contact failure problem of air contact type relays. Since there are few driving parts and the Mechanical life is long, it has a long life even in high-frequency switching applications. When the inductive load is interrupted, glow discharge is performed, so there is little surge voltage, and it is a product that is friendly to the electronic parts of peripheral equipment. Since it is a mechanical contact, complete insulation can be obtained, so it is possible to prevent events such as equipment Malfunction due to leakage current of the semiconductor relay.

Request for a quote

Germany

Limit value switch for frequency (direct current). Simple application; for rough environments. Limit value freely adjustable by drum scale. Open-circuit or closed-circuit devices available. Compact and robust construction. Operating status indication by integrated LED. Approvals: BV, DNV-GL, LR

Request for a quote

Germany

Rack mounting power supply, primary switched, remote controllable Input AC 100 - 240 V (wide range), Active-PFC For use in switch cabinets (TS35-rail acc. to EN 60715) Electrical safety / test report: IEC 60950-1, EN 60950-1, UL 60950-1, CSA 22.2 No. 60950-1, UL 508, IEC 62103, EN 50178 etc. EMC: EN 55011 Class B, EN 61000-3-2, EN 61000-6-2, EN 61204-3 No inrush current Floating relay contact Digital-I/O, Analog-IN (0 - 10 V or 4 - 20mA) Interface: RS-232 Very low stand-by-power, high efficiency (smooth behaviour across total input voltage range) Extensive protection for power output: short circuit, no-load, overvoltage, overtemperature

Request for a quote

Germany

Rack mounting power supply, primary switched, remote controllable Input AC 100 – 240 V (wide range), Active-PFC For use in switch cabinets (TS35-rail acc. to EN 60715) Electrical safety / test report: IEC 60950-1, EN 60950-1, UL 60950-1, CSA 22.2 No. 60950-1, UL 508, IEC 62103, EN 50178 etc. EMC: EN 55011 Class B, EN 61000-3-2, EN 61000-6-2, EN 61204-3 Very low stand-by-power, high efficiency (smooth behaviour across total input voltage range) No inrush current Floating relay contact, Digital-I/O, Analog-IN (0 - 10 V or 4 - 20 mA) Interface: RS-232 Extensive protection for power output: short circuit, no-load, overvoltage, overtemperature

Request for a quote

Germany

Input AC 100-240V, Active-PFC wide range For use in switch cabinets (TS35-rail acc. to EN60715) Electrical safety / test report: IEC 60950-1, EN 60950-1, UL 60950-1, CSA 22.2 No. 60950-1, UL 508, IEC 62103, EN 50178 etc. EMC: EN 55011 Class B, EN 61000-3-2, EN 61000-6-2, EN 61204-3 No inrush current Floating relay contact, Digital-I/O, Analog-IN (0 - 10 V or 4 - 20 mA) Interface: RS-232 Very low stand-by-power, high efficiency (smooth behaviour across total input voltage range) Extensive protection for power output: short circuit, no-load, overvoltage, overtemperature

Request for a quote

Germany

Rack mounting power supply, primary switched, remote controllable Input 380 - 500 V; 3 AC (wide range), Active-PFC For use in switch cabinets (TS35-rail acc. to EN 60715) Electrical safety / test report: IEC 60950-1, EN 60950-1, UL 60950-1, CSA 22.2 No. 60950-1, UL 508, IEC 62103, EN 50178 etc. EMC: EN 55011 Class B, EN 61000-3-2, EN 61000-6-2, EN 61204-3 Very low stand-by-power, high efficiency (smooth behaviour across total input voltage range) No inrush current Floating relay contact, Digital-I/O, Analog-IN (0 - 10 V or 4 - 20 mA) Interface: RS-232 Extensive protection for power output: short circuit, no-load, overvoltage, overtemperature

Request for a quote

Germany

Rack mounting power supply, primary switched, remote controllable Input AC 100 - 240 V (wide range), Active-PFC For use in switch cabinets (TS35-rail acc. to EN 60715) Electrical safety / test report: IEC 60950-1, EN 60950-1, UL 60950-1, CSA 22.2 No. 60950-1, UL 508, IEC 62103, EN 50178 etc. EMC: EN 55011 Class B, EN 61000-3-2, EN 61000-6-2, EN 61204-3 Extensive protection for power output: short circuit, no-load, overvoltage, overtemperature Very low stand-by-power, high efficiency (smooth behaviour across total input voltage range) No inrush current Floating relay contact Digital-I/O, Analog-IN (0 - 10 V or 4 - 20mA) Interface: RS-232

Request for a quote

Germany

Rack mounting power supply, primary switched, remote controllable Input AC 100 – 240 V (wide range), Active-PFC For use in switch cabinets (TS35-rail acc. to EN 60715) Electrical safety / test report: IEC 60950-1, EN 60950-1, UL 60950-1, CSA 22.2 No. 60950-1, UL 508, IEC 62103, EN 50178 etc. EMC: EN 55011 Class B, EN 61000-3-2, EN 61000-6-2, EN 61204-3 Extensive protection for power output: short circuit, no-load, overvoltage, overtemperature Very low stand-by-power, high efficiency (smooth behaviour across total input voltage range) No inrush current Floating relay contact Digital-I/O, Analog-IN (0 - 10 V or 4 - 20 mA) Interface: RS-232

Request for a quote

Germany

Rack mounting power supply, primary switched, remote controllable Input 380 - 500 V; 3 AC (wide range), Active-PFC For use in switch cabinets (TS35-rail acc. to EN 60715) Electrical safety / test report: IEC 60950-1, EN 60950-1, UL 60950-1, CSA 22.2 No. 60950-1, UL 508, IEC 62103, EN 50178 etc. EMC: EN 55011 Class B, EN 61000-3-2, EN 61000-6-2, EN 61204-3 No inrush current Floating relay contact, Digital-I/O, Analog-IN (0 - 10 V or 4 - 20 mA) Interface: RS-232 Very low stand-by-power, high efficiency (smooth behaviour across total input voltage range) Extensive protection for power output: short circuit, no-load, overvoltage, overtemperature

Request for a quote

Germany

The sensor system is intended as a component for use e.g. in wind power plants to measure and evaluate vibrations in the mast head. Registration of dynamic accelerations by means of MEMS sensors (Micro-Electro-Mechanical System) with subsequent digitisation by a controller. The device consists of an acceleration sensors, a controller unit and three types of output interface. Data output is carried out via two analogue interfaces with 4 ... 20 mA plus CANopen and via 4 relay contacts (currently 1 error relay contact). The NVA is parameterised via the CANopen interface. This is not galvanically separated. The sensor is equipped with a filter circuit to protect against fast transients and surge voltages of up to 2 kV in the supply. The protection types are IP 69K (housing) and IP 67 (connector/socket). With its good vibration and shock values, the sensor is suitable for use in areas with rough environmental conditions.

Request for a quote