• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • electric measuring instruments

Results for

Electric measuring instruments - Import export

Germany

Verified by Europages

LT80 multifunction display with interface modules and clearly structured user interface Connection of up to 32 DK or DT probes (DT probes with MT adapter) Easy installation on DIN mounting rail High speed trigger module When connecting an encoder with TTL output pulses to the trigger module, measured values from up to 16 probes can be read out synchronously in dynamic applications The synchronous measurement data can be stored on the LT80 between LT80-NE Display 7-inch touchscreen LCD display for 2 to 16 measurement channels Different measurement modes and measurement functions selectable: Current value, MAX, MIN, P-P, ADD/SUB function, 2 or 4 step comparator function for automated measuring and sorting Display I/O status 3 different interfaces (USB stick, SD card, LAN) for data storage, data transfer and parameterization Different menu languages selectable (English, German, Japanese)

Request for a quote

Germany

Verified by Europages

For connection of up to three DK probes with adapter cable CE29 or linear encoder. Equipped with RS-232C function as standard Peak value function, hold function Various input functions especially for automatic measurements Selectable display resolution Data storage Reset/Preset/Restart With reference point recognition of the connected measuring units Scaling function

Request for a quote

Germany

Verified by Europages

Counter display for connection of up to two DK probes with adapter cable CE29. Various data outputs can be made possible by installing expansion cards BCD output with LZ71-B card (optional) Comparator function: relay / open collector output with LZ71-KR (optional) Peak value acquisition / hold function Various input functions especially for automated measurements Selectable display resolution Data storage Reset/Preset/Restart With reference point recognition of the connected measuring units Scaling function Flicker control

Request for a quote

Germany

Verified by Europages

Incremental length probe with magnetic detection principle for high reliability. Very high accuracy and repeatability Extremely insensitive to contamination such as oil mist, moisture and dust Ball spline bearing of the spindle for long life time Perfectly suited for automated measured value acquisition in measuring devices, assembly and manufacturing lines

Request for a quote

Germany

Verified by Europages

Incremental length probe with magnetic detection principle for high reliability. Very high accuracy and repeatability Extremely insensitive to contamination such as oil mist, moisture and dust Ball spline bearing of the spindle for long life time Perfectly suited for automated measured value acquisition in measuring devices, assembly and manufacturing lines

Request for a quote

Germany

Verified by Europages

Bourdon takes mechanical pressure monitoring into the digital age This innovative device fits to any comprehensive platform for machine and process monitoring as well as the preventive maintenance of equipment which is supported by a LoRa wireless protocol. Key applications include pressure measurement and monitoring for oil refineries, petrochemical industry and biodiesel plants. More predestined applications are in waste and water treatment, power generation and transmission, general process industry, building services and civil engineering. The right choice when industry grade wireless pressure measurement and monitoring is required

Request for a quote

Germany

Verified by Europages

In this training course, you will learn about different measurement methods that you can use for your measurement tasks. You will learn how to select and apply the appropriate measurement method. You will get an overview of the advantages and disadvantages of different measurement methods, such as optical, acoustic, or electrical methods. The training is aimed at anyone involved in measurements, e.g. engineers, technicians, quality managers or scientists. The training lasts one day and covers the following topics: Measuring principles and application examples; Optical, electrical, thermal, mechanical, ... measurement; From measurands to measurement data; Structuring the test task; Documentation.

Request for a quote

Germany

Verified by Europages

We plan, build and deliver turnkey test systems for electronic and mechanical components. For example, these are test benches for quality assurance, validation and production departments of companies in various industries. Our services include e.g.: - Development test benches - Life time test benches - End-of-line test benches (production) - Retrofit of existing systems (software / hardware) - Climate & temperature test systems - Leakage test benches - Software development LabVIEW, TestStand, Python, C/C++ (Embedded), Microsoft PowerBI, SQL - Electronics development - Mechanical 3D CAD design - Risk assessment and CE - Commissioning, service, maintenance at home and abroad

Request for a quote

Germany

Verified by Europages

EOL test stand for e-charging columns and their power electronics for the simulation of different electrical loads and mains fluctuations. The test stand has automatic contacting and achieves high test throughputs in end-of-line operation. Different variants of the power electronics of electric charging columns can be tested. On the software side, Merecs Engineering relies on NI-LabVIEW and NI-TestStand.

Request for a quote

Turkey

LEGA ENERGY TURKEY/LEGA ENERJİ TÜRKİYE // *Line Interactive UPS *Monophase In Monophase Out UPS *Triphase In Monophase Out UPS *Triphase In Triphase Out UPS *RACK MOUNT UPS *Triphase In Triphase Out UPS With TRANSFORMER(T SERIES) //

Request for a quote

Germany

Power Management Controller for power supply and system protection Can be used as an independent system or as an extension to a NORISYS 4 automation platform Option for connecting a colour touch panel as HMI and visualisation USB port for configuration and service RS-485 for NORISYS 4 ExtBus communication Generator set control with automatic start/stop function Parallel and isolated operation Automatic synchronisation Generator protection functions, 3-phase Power supply protection function, 3-phase Approvals pending: BV, DNV, GL, LR

Request for a quote

Switzerland

Front dimensions: 144 x 144 mm Input voltage / current: 4/4 - neutral current measured Class 0.1 (U/I), Class 0.2 (P/Q/S), Class 0.5 S (meters) Disturbance recorder ≤3 min Ethernet (Modbus/TCP, web server, NTP) Option: RS485 (Modbus/RTU)

Request for a quote

Germany

The F02 has been designed for application in systems which require a pressure transmitter with a Performance Level PL d or a Safety Integrity Level of SIL 2. It has a thin-film measurement cell made from stainless steel which is welded together with the pressure sensor and thus guarantees high media compatibility. It is available within pressures from 10 to 1200 bar. The output signal is made available at two outputs in parallel, whereby the second output represents an inverted signal. Users can select between a ratiometric and an 4-20-mA output in three-wire technology. The permitted media temperature range extends from -40…+125 °C. The total accuracy in the compensated range of 0…+80 °C lies at <= 1 % FS. The possible flexibility during integration into an existing machine is ensured through the provision of a multitude of available pressure connections as well as the small construction. The electrical contact takes place via a 5-pole M12 connector. The F02 also has E1 approval.

Request for a quote

Switzerland

Front dimensions: 144 x 144 mm Input voltage / current: 3/3 Class 0.2 (U/I), Class 0.5 (P/Q/S), Class 1.0 (meters) RS485 (Modbus/RTU) Option: Ethernet (Modbus/TCP, web server, NTP)

Request for a quote

Switzerland

Front dimensions: 96 x 96 mm Input voltage / current: 3/3 Class 0.2 (U/I), Class 0.5 (P/Q/S), Class 1.0 (meters) Disturbance recorder ≤3 min 1 Dig. OUT ; 1 Dig. IN/OUT Option: Ethernet (Modbus/TCP, web server, NTP) and RS485 (Modbus/RTU)

Request for a quote

Germany

The pressure switch P01 has been designed especially for use in mobile machines. The EMC characteristics as well as the impact and vibration resistances have been designed for this field of application. This facilitates their use in adverse ambient conditions such as can be found in mobile hydraulics. The integrated electronic switches (NPN or PNP) can be preconfigured ex-works. The P01 is available for pressure ranges from 0...10 bar to 0...1200 bar, whereby a switching accuracy of 1 % of the measurement range end value can be achieved. The maximum permitted media temperature totals 150 ºC; the ambient temperature totals 125 ºC. The parts coming into contact with media have been produced from stainless steel (1.4548) and guarantee, in combination with the welded thin-film measurement cell, maximum media compatibility. Optionally, a damping device can be integrated into the media access.

Request for a quote

Germany

To ensure that an instrument provides accurate measurements, regular calibrations are necessary. Calibration means to operate a target-performance comparision using a measuring instrument and a traceable reference. Calibration of instruments is essential in every area where sensitive measurement technology is used, e.g. in the manufacturing of sensors. It is the only way to guarantee quality standards and prevent defects arising in processes and products from the outset. For companies wanting to attain ISO 9001 certification, regular calibration of testing equipment is a requirement. halstrup-walcher has been accredited by the German calibration service DKD and Deutsche Akkreditierungsstelle GmbH (DAkkS) as a calibration laboratory in accordance with DIN EN ISO / IEC 17025 since 1999 – among other things for calibration of pressure measurements.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

The M01 series has been especially designed for applications in adverse ambient conditions in the same way value is placed on high resistance to aggressive media. Furthermore, the modular principle permits many combinations of pressure connection, pressure range, output signal and connector, so that the right sensor can be found for most applications. For pressure ranges from 10 to 2000 bar, which are frequently required for use on mobile machines, welded stainless steel measurement cells are used which are suitable for media temperatures from −40 to +150 °C. Depending on the type of measurement cell and the material coming into contact with the media, the M01 is resistant to aggressive/non-aggressive gases and liquids. On request, versions in 316L design for use in hydrogen pressure measurements are available. In addition to CE and UL certificates, every M01 product with a 1.4542 stainless steel measurement cell possesses an E1 approval verifying its suitability for use in vehicles.

Request for a quote

Russia

Tsiatim-221 (All Union State standard – GOST 9433-80) grease is a high quality lubricant. Made from silicone oil combined with a thickener. Retains unique performance levels over a wide temperature range. Main characteristic The lubricant has a complex of additives to obtain a unique antioxidant effect in operation. It does not lose its original properties at high temperatures and pressure drops. Benefits - frost resistance - thermal stability - adhesion - all-season - chemical inertness - there is no destructive effect for rubber elements - low volatility. Tsiatim-221 is used to lubricate friction units, mating surfaces. A stable effect is guaranteed at -60 to + 150 C. The main effect due to which the lubricant is in demand is the preservation of viscosity at any negative temperature. Ideal for machining bearings of electric machines, high speed measuring instruments, equipment assemblies.

Request for a quote

Germany

Pressure transmitter/Pressure switch PASCAL CSfor general applications, Type series CS2100 Multifunctional pressure transmitter/pressure switch Degree of protection IP 65 4 digit LED display, can be mirror-imaged by 180° Indication module can be turned through 300° Measuring ranges 0…100 mbar to 0…40 bar rel., 0…1 bar to 0…6 bar abs, High pressure 0…60 bar to 0…400 bar Output signal 4…20 mA, 2-wire technology Accuracy: ≤ 0.2 % Easy to program locally (as per VDMA standard) Galvanic isolation between transmitter and switching outputs Various process connections Options 2 floating contacts Switching contacts with high switching current (1A) Inspection certificates - material certificate per DIN EN 10204-3.1 - calibration certificate per DIN EN 10204-3.1 Electrical connection rotatable by 300° Degree of protection IP 67

Request for a quote

Germany

The digital differential pressure transmitter PASCAL Ci4 Delta P has been specially designed for the mounting of diaphragm seals with a volume reduced differential pressure chamber. Due to this design the transmitter is suitable for various applications, e.g. for the level measurement of pressure vessels.

Request for a quote

Germany

Analogue pressure and differential pressure transmitter series Features: Analogue pressure and differential pressure in numerous designs Proven reliability in numerous designs and processes Piezoresistive measuring system or thin film Measuring system high overload protected Wetted parts of stainless steel Degree of protection IP 65 Options: Explosion protection for gases and dust GL (Germanischer Lloyd) certificated (CB1/CE1 only) Degree of protection IP 67 Classification per SIL2 (COMPACT)

Request for a quote

Germany

Pressure transmitter with diaphragm seal technology for the measuring of relative and absolute pressures of gases, vapors and liquids Stainless steel case in sturdy design, degree of protection IP 65/67 Accuracy 0.1 % High-resolution graphic display with Intuitive 4-button operation and backlight Comprehensive parameterising functions Comprehensive simulation and diagnostic functions Quick access to device data Development according to SIL2 Nominal range 0,25 bar to 400 bar Turndown up to 100:1 Measuring rate up to 100 Hz Output signal 4…20 mA with HART® protocol Configuration memory Digital communication via PDM, FDT/DTM, 375/475 Field Communicator Output functions: linear, invers, square root, table function with up to 64 support points Media temperature -40…400 °C Case design process connection bottom Case design process connection back Various process connections Approved according to NAMUR 95 EAC declaration (upon request)

Request for a quote

Germany

High-resolution graphic display with backlight Intuitive 4-button operation Comprehensive parameterising functions Comprehensive simulation and diagnostic functions Quick access to device data Development according to SIL2 Nominal range 0.25 bar to 40 bar Turndown up to100:1 Measuring rate up to 100 Hz Accuracy 0.1 % Output signal 4…20 mA with HART® protocol Configuration memory Digital communication via PDM, FDT/DTM, 375/475 Field Communicator Output functions: linear, invers, square root, table function Table function with up to 64 support points Stainless steel case in hygienic design, degree of protection IP 65/67 Media temperature up to 160 ° C Wetted parts stainless steel Case design: - process connection bottom - process connection back Various hygienic process connections Approved according to NAMUR 95 EAC declaration (upon request)

Request for a quote

Germany

Pressure transmitter PASCAL CV4 threaded connection, type series CV4100 Features Compact case of stainless steel in hygienic design according to recommendations from EHEDG and 3A, degree of protection IP 65/67 Accuracy ≤ 0.15 % High-resolution graphic display with Intuitive operation and backlight Quick access to device data Comprehensive parameterising, simulation and diagnostic functions Nominal range 0.25 bar to 400 bar Turndown up to 20:1 Output signal 4…20 mA with HART® protocol Output functions: linear, invers Table function with up to 32 support points (in preparation) Wetted parts stainless steel Process connection: screw-in thread with internal diaphragm Options Accuracy ≤ 0.1 % Explosion protection for gases and dust (in preparation) Classification per SIL2 (in preparation) Material certificate per EN 10204 Calibration certificate per EN 102044

Request for a quote

Germany

Universal pressure transmitter Features: Stainless steel case, degree of protection IP 65 Direct ventilated sensor element Measuring ranges: 0…100 mbar to 0…400 bar rel.; 0…1 bar to 0…6 bar abs. Accuracy ≤ 0.2 % Further features Options: Approvals/Certificates: Certificate of measuring equipment for Russian Federation; Material certificate as per EN 10204-3.1; Calibration certificate as per EN 10204-3.1 Degree of protection IP 67

Request for a quote

Germany

Features Measurement of relative pressure of gases, vapours and liquids Output signal: 4…20 mA, 2-wire technology Stainless steel case, degree of protection IP 65 Easy zero setting by means of a magnet Accuracy ≤ 0.5 % Options: Output signal (invers) 20…4 mA Accuracy ≤ 0.3 % Hygienic design

Request for a quote

Germany

Pressure transmitter COMPACT Features: Measuring ranges 0…250 mbar up to 0…100 bar Linearity error including hysteresis <+ 0.2 % f.s. Piezoresistive measuring system Hygienic design according to EHEDG, FDA and GMP recommendations Material and surface quality according to the hygienic requirements Wetted parts of stainless steel; completely welded Stainless steel housing as standard or field housing Degree of protection IP 65, IP 67 option Output signal: 4…20 mA Process temperature up to 200 °C Options: Explosion protection for gases Classification per SIL 2 Inspection certificate: material certificate as per DIN EN 10204-3.1

Request for a quote

Germany

Features ■ Pressure transmitter with on-site indication for relative pressure measurements ■ Safety pattern gauge S3 per EN 837-1, NS 100 and 160 alternative high quality case with bajonet ring per EN 837-1 S1 ■ Nominal range 0…0.6 bar up to 1000 bar ■ Output signal: 4…20 mA (20…4 mA) 2-wire technology ■ Integrated angle-of-rotation sensor, not subject to wear ■ EAC declaration (upon request) Options ■ Approvals/Certificates - Calibration certificate - Explosion protection for gases and dust - Certificate of measuring equipment for Russian Federation - Material certificate as per EN 10204-3.1 ■ The electrical zero can be corrected by holding a ferromagnetic object to a marked location on the case ■ Additional switch function ■ Diaphragm seals see product group D5 ■ Output signal 0...20 mA and 0...10 V in 3-wire technology (for devices without Ex-protection and without zero point setting)

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free