• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • flow indicator

Results for

Flow indicator - Import export

Germany

Verified by Europages

CheMobil made of PMP/TPX can be used for many substances due to its good chemical resistance. Not suitable for strong acids, alkalis and solvents. CheMobil can be steam sterilised. Flow indicators give precise visual indication of the flow velocity of liquids or gases being transported through hose connections. The flow indicator with impeller functions in both directions and in any position. The impeller starts to rotate at a flow rate about 150 ml/min (liquids).

Request for a quote

France

Verified by Europages

A flow indicator or flow monitor makes it possible to visually observe the passage of a fluid. It is therefore equipped with a transparent window to visualize the flowing fluid. In the case of transparent fluids, it is also equipped with fins that can be seen rotating in the presence of a flow.

Request for a quote

Germany

Your benefits User friendly Flexibility for different needs Compact design Many possibilities for installation Convenient for all our flowmeter range Solid, resistant and long term robustness Areas of application The universal converters are used as flow indicators and for batching control of miscellaneous liquids: water, industrial liquids, fuel etc.. These converters are designed for industrial environments. Four versions are available: flow totaliser F113, differential flow measurement F116/F127 with temperature compensation and batching control F131 (non explosive environment) and F131 Exi (explosive environment).

Request for a quote

Germany

Verified by Europages

EGE amplifier complement the EGE flow sensors without integrated amplifier. They process the signals of a measuring sensor and visualise the flow state using an LED indication. In addition, they provide switching or analogue outputs for flow and temperature to the control. The device set-up is easy and takes place using a potentiometer or the buttons on the front. The devices are installed in a control cabinet or comparable protected housing. The EGE amplifier of product series SKM 420; SKM 520; SKM 552 are suitable for supply with 24 V DC or 230/115 V AC.

Request for a quote

Germany

Analogue flow indicators for measuring the flow rate of fluids in mobile and industrial hydraulics. The SDMKR is designed with a loading valve for the strain test of the hydraulic system to facilitate precise control of the operating pressure. In addition, this product can also be subjected to a reverse flow direction (without flow rate determination). ▪ Suitable for Mineral Oil (Aluminium), HFC Fluids and Water (Brass) ▪ Designed for in-line installation ▪ Mechanical flow measurement ▪ Controlling working pressure with a pressure control valve (only SDMKR) ▪ Flow indication in l/min and GPM for Aluminium units, Brass units have flow indication for Water and Oil both in l/min ▪ Aluminium unit: Dual scale ▪ Brass unit: Single scale ▪ Thread to connect with pressure gauge (only SDM) Accuracy (at a kinematic viscosity of 28cSt): ▪ Flow: ±4 % FSD ▪ Temperature: ±2,5 °C / ±5 °F ▪ Pressure (only SDMKR): ±1.6 % FS* ▪ Temp. measuring range: +20 °C ... +110 °C / +55 °F ... +245 °F ▪...

Request for a quote

Germany

Flow sight glasses type N880A-K (DIN length F1) connection with ANSI flanges & with indicator flap

Request for a quote

Germany

Flow sight glasses type N880-K, DIN 3237, with indicator flap

Request for a quote

Germany

Flow Sight Glass Type Type N880-SOW with pipe – socket – weld connection Use: The flow indicators are used for optical control of fluids and gases, for horizontal and vertical pipe-lines. Also available with internal spinner or flap.

Request for a quote

Turkey

It is an easily adjustable and useful machine. Work efficiency is high. Our warehouses are produced from polyethylene against the harmful effects of pesticides. In gasoline models, HONDA GX160 model gasoline engine is used. In the electric model, a single-phase electric motor is used. The water filter can be cleaned easily. Thanks to the regulator, the pressure can be adjusted according to demand. In this way, spraying can be done at the desired flow rate. There are level indicators on both sides of the tank. It can be easily connected to the tractor with the trailer tongue with pull type wheel jack system.

Request for a quote

Germany

STAUFF BPS Bypass Filter can be used for OEM first fit applications as well as for retro-fitting. The filtration is done in a bypass configuration from the main hydraulic system.. Clogging Indicator (available as an option) ▪ Visual clogging indicator Valves ▪ Flow control valve Filter Elements ▪ Filter Elements of SRM series Construction ▪ Bypass Filter Units are especially designed for mobile applications in hydraulic and/or transmission systems ▪ No special motor/pump unit neccessary ▪ Single or double housing Nominal Flow Rate ▪ Max. 4,2 l/min / 1.1 US GPM Max. System Volume ▪ Up to 1.500 l / 400 gal Port Connections ▪ G1/4, G1/2 Materials ▪ Anodised Aluminium Media Compatibility ▪ Mineral or lubrication oils, others on request

Request for a quote

Austria

Automatic synchronization to the line over a 1:6 speed range (requires a 0 V to 10 V signal proportional to the line speed); for lines providing no such control signal a dedicated frequency generator with tachometer wheel and incremental encoder is required. V - AUTOMATIC VISCOSITY CONTROL FOR PRINTING INKS An oscillating sensor causes thinner to be added when the viscosity deviates from a preset value. LD - INK LEVEL SENSOR AND INDICATOR SYSTEM Triggers a warning signal as the ink level drops below minimum. FW - INK FLOW SENSOR AND INDICATOR SYSTEM Triggers a warning signal as the ink flow deviates by an adjustable amount from the preset value. MARKING DRUMS Easily replaceable pairs of marking drums for use as spares for supplied marking drums or for changing the ring spacing or pattern. Standard ring patterns include single or double rings every 17 mm; double rings every 34 mm; one, two, three, or four rings every 60 mm

Request for a quote

Germany

The Flo-Tronic Plus™ is based on a standard Flo-Meter™ with or without a manual flow control valve. It provides visual flow rate indication as required by NFPA as well as an analog output in direct relation to the flow rate. The Waukee new magnetic flow sensing technology is immune to problems associated with dirty oil. Ideal for customers who need to data log flow rates for compliance to NADCAP, AMS 2750D, or CQI 9. FEATURES • Meets NFPA requirements for visual indication of flow • Isolated 4-20mA current loop output • Over current and reverse polarity protection • Calibrated in our ISO/IEC17025-2005 Calibration Lab and traceable to NIST (National Institute of Standards and Technology) • Multipoint calibration • Simple Installation • Modbus/TCP communications • 1 Programmable relay out • Easily connects to any PLC or controller with differential or single ended analog inputs • Retrofittable to most existing Waukee Flo-Meters

Request for a quote

Germany

Stainless steel heating circuit distributor, with adjustable flow indicators for supply flow and thermostat valve inserts for return flow, incl. wall bracket and draining set

Request for a quote

Germany

CHARACTERISTICS high operating safety robust, compact design pressure resistant up to 350 bar easy maintenance flow direction selectable drag indicator as standard Dual scale bar / psi or mbar / kPa universally applicable selectable display indicating range OPTIONS helium application on demand plastic housing stainless steel housing static pressure max. 450 bar GENERAL The differential pressure gauge DP 900 serves to monitor the differential pressure of filter systems, measuring systems, valves, coolers, heat exchangers, in petrochemical, as well as in gas and air systems. Preferably, the DP 900 is applicable for air and gas technical systems. The gauge housing made from aluminum is designed compact and robust. It is pressure-resistant up to 350 bar. FUNCTION A determined path of a freely movable piston measures the differential pressure. The piston retains against a compression spring. The magnetic spool-measuring device unit is been installed to the main housing.

Request for a quote

Greece

Agromasters introduces the new HERMES ACR controller , A brand new solution for automatically removing milking unit from Cow or sheep and goats with accuracy, when volume of milk flow drops below a pre-configured minimum flow rate. Hermes ACR system can create substantial increase in productivity per milker.. The integration of HERMES ACR controllers in any type of milking system can help maintaining milk quality ,increasing milking efficiency & reducing animal health issues , which is usually coming from over – milking periods. Technical characteristics Simplicity & efficiency. Simple push-button control (Manual, Milk, Detach). Led indications . Indication with red lamp of all available operating modes (Manual , Detach , Milk) . Led indication, when milk flow has stopped. Easy configuration .A wide range of settings available on HERMES CONTROLLER , according to animals being milked (Cows, Goats or Sheep) .

Request for a quote

Germany

Softcontrol Data offers individual setting options and a clear presentation of the information on the display. The device is a comprehensive alarm system for upstream water softening systems with high safety requirements for the soft water quality. The limit values ​​for the water hardness can be set in the range from 1 ppm to 18 ppm based on the input water hardness. The measurement data and service messages are automatically saved in the readable, integrated USB stick and transmitted via a current loop and LAN interface with MODBUS / TCP. For increased operational and process reliability with the best user friendliness. A continuous measurement takes place approx. 2 times per minute as long as water is flowing. indicators are not used and an ion-selective sensor is used instead. This monitors itself and indicates the required exchange itself. This is usually the only maintenance on the device that has to be carried out around twice a year.

Request for a quote

Germany

Softcontrol RM monitors the soft water produced by the softener for increased hardness concentrations and also triggers the regeneration of the softener in terms of quality. The monitoring of variable water hardness limit values from 1 ppm to 18 ppm takes place as well as the quality-controlled triggering of the regeneration of two columns of the softener. A continuous measurement takes place as long as water flows. Indicators are dispensed with and low-maintenance ion-selective sensors are used instead. The device has self-monitoring so that, in the event of service, information is provided automatically for less maintenance. The measured values are output on the display, via a 4 to 20 mA current loop and via a LAN data interface with Modbus / TCP. The data is also saved in the electronic operating log (USB stick). Installation and parameterization is easy to carry out on the device.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Control valve and Flow indicator for use with calibration gas cylinder. Flow meter markings are nominally 0.5 & 1.0 litres/min.

Request for a quote

Ukraine

Automatic belt scales (belt weigher) SWEDA VK are designed for continuous measurement of the mass of bulk and lumpy materials transported by belt conveyors and indication on a digital display of the current conveyor performance and the value of the mass of weighed bulk and lumpy materials on a accrued total during commercial, accounting and technological operations. Features: - Accurate weighing and accounting of material in the flow (± 0,5%); - Measurement and indication of momentary сapacity; - Summation and indication of the total weight per shift, day, total; - Wide operating temperature range; - Possibility of calibration and verification without material overweight; - Modular construction, which makes it easy to transport and mount the scales directly at the enterprise; - Data output to a remote display and a computer as part of the process control system; - More than 1000 serial samples are in operation in 15 countries.

Request for a quote

Netherlands

Venrius has a broad range of purgemeters. The purge rotameters are intended for general use as a low-cost method of flow indication. It is suitable for the majority of non-critical purge applications that do not necessarily require high flow measurement accuracy. Their primary use is to regulate small gas or liquid purge streams. They are used to keep instruments from coming into contact with hot and corrosive fluids, to keep pressure taps from plugging, to keep optical devices clean, and to keep electrical devices from igniting when they come into contact with flammable materials.

Request for a quote

Netherlands

Venrius' portfolio includes a variety of variable area flowmeters. Metal tube variable area flowmeters, glass tube variable area flowmeters, and purge rotameters are the three main types. The volumetric flow rate of liquids and gases is measured using the float principle in metal and glass tube flowmeters. The purge flowmeter is intended for general use as a low-cost method of flow indication. It is suitable for the majority of non-critical purge applications that do not necessarily require high flow measurement accuracy.

Request for a quote