• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • process control

Results for

Process control - Import export

FranceManufacturer/producer

France

Verified by Europages

REP Net 4.0 is a software that belongs to REP Pack 4.0. 4th generation of presses network, since the 1st version in 1987 and still compatible with previous generations of presses. REP Net 4.0 fits into Industry 4.0 and provides Cycle traceability (set value, measured value, compound, operator, SPC calculation) Centralizing and mold settings transfer Modelling the workshop, help for production management

Request for a quote

France

Parker Hannifin is the world leader in the development, production and marketing of components, systems and solutions in the field of control and motion. Parker supplies products in 9 technologies : hydraulics, pneumatics, electromechanics, filtration, process control, connectors, sealing, air conditioning and aerospace . ​ With a large distribution network around the world, you can rest assured that you can find a Parker distributor near you who can provide technical support, meet your needs and provide troubleshooting and maintenance.

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Measurement of oxygen in gases Process control Brand : SETNAG ADVANTAGES : No need for reference gas: use of the MicroPoas® Semi in situ measurement (excellent reliability) Free circulation of the gases Easy and fast set-up Almost maintenance free, cost effective service MEASUREMENT TECHNIQUE The S24N-2020 analyser fits CEM systems Oxygen measurement on wet gas (direct connection at heated hose outlet) Oxygen measurement on dry gas (after sample conditioning) EXAMPLES OF APPLICATIONS Power generation, district heating operation... Incineration of industrial and domestic waste Steam production Steel works VOC incineration Control of processes...

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business