• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • level monitors

Results for

Level monitors - Import export

Germany

Verified by Europages

Areas of Application and Advantages BEDIA CLS 10 stands for special versions of our well-proven CLS 40 series for heavy duty applications. Currently, the BEDIA CLS 10 series includes a variety of sensors, which are compatible replacement parts for level switches from Cooper Standard and Robert Shaw which are obsolete nowadays – and this in well proven BEDIA quality. This also includes sensors with 2 complementary CMOS outputs. It should be emphasized that the water sensors with two complementary outputs can be operated with a supply voltage of 4.75 V DC – 32 V DC. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that arises when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator, causing it to oscillate (at a frequency of approx. 600 kHz). Then this signal is processed by a microprocessor-based evaluation circuit.

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors detect when a filling level is exceeded or falls below a limit. Water-based liquids like coolants, AdBlue®, fresh water, waste water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that occurs when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator. This signal is processed by a microcontroller-based evaluation circuit which activates or deactivates an output stage. Types of Media The level monitoring sensors are designed for two different media types: For electrically conductive liquid media with relative permittivity within a range of εr 35 … 85 (water, coolant, water/glycol mixture) For electrically non-conductive liquid media

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors detect when a filling level is exceeded or falls below a limit. Water-based liquids like coolants, AdBlue®, fresh water, waste water, bilge water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Since they contain no mechanical moving parts, their function will not be influenced by dirt particles or other influences. No electrical current is sent through the medium via an electrode with BEDIA sensors, an electrolysis of the medium is not possible. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that occurs when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator. This signal is processed by a microcontroller-based evaluation circuit which activates or deactivates an output stage.

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors react when a filling level is exceeded or falls below a limit. Aqueous mediums like coolants, AdBlue®, fresh water, waste water, bilge water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Since they contain no mechanical moving parts, their function will not be influenced by dirt particles or other influences. No electrical current is sent through the medium via an electrode with BEDIA sensors, an electrolysis of the medium is not possible. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that arises when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator, causing it to oscillate. Then this signal is processed by a microprocessor-based evaluation circuit.

Request for a quote

Germany

Verified by Europages

We offer the appropriate interface device for separating, forming, processing, converting and conditioning analog signals. The product portfolio comprises analog signal isolators, isolating transducers, temperature measuring amplifiers, potentiometer amplifiers, trip amplifiers and level monitors - for simple and complex requirements, for Ex- and non-Ex applications, available in the IP20 housing for DIN rail as well as in the compact IP67 housing for decentralized on-site remote control.

Request for a quote

France

Verified by Europages

Radar sensor for measuring the level in silos and containers. Available for silos up to 120 m height. Can be used for a wide variety of materials, regardless of the size or composition of the material. • 80 GHz allround sensor • continuous measurement • maintenancefree operation through noncontact measuring principles • reliable measurement independent of vapour, dust and noise

Request for a quote

France

Verified by Europages

Microwave barrier for contactless detection of dry bulk solids in containers, pipes or chutes. Reliable fill level and limit detection. • simple retrofitting • detection through all nonconductive walls • up to 1,000 °C possible with ceramic mounting • insensitive to material caking • usable for profiles up to 25 m

Request for a quote

France

Verified by Europages

Microwave barrier for contactless detection of dry bulk solids with fillingsignalsuppression in containers or chutes. Reliable fill level and limit level detection. • indicates level and material flow • with filling signal recognition • up to 1,000 °C possible with ceramic mounting • insensitive to material caking • usable for profiles up to 25 m • no measurement failure due to strong material flow for filling

Request for a quote

France

Verified by Europages

Controller based filter dust leak monitor (0100%) for filter emissions monitoring after bag houses, cartridge filters, cyclones etc. where performance approvals are not required. • reliable monitoring of leaking and broken bags in dust collectors • sensor configured remotely via controller • manual sensor drift checks • probe check option for improved data integrity • reduces filter maintenance intervals, process downtime and filter costs

Request for a quote

France

Verified by Europages

Housing fibreglass reinforced thermoplastic polyamide. Sight glass thermoplastic polyamide. O-ring and flat seal NBR. Reflector PVC. Float plastic. Screw and nut, steel. Version: Housing black. Sight glass crystal clear, high mechanical stability, non-ageing. Reflector white. Float red, with magnetic element. Screw and nut electro zinc-plated. Note: The oil level gauge not only enables the oil level to be viewed but also recorded using a REED switch. In addition, the oil level gauges can also emit an electric signal if the temperature of the liquid inside the container reaches the threshold of 70 °C. As soon as the float element approaches the selected minimum value after the circuit has been closed, the system emits an electric signal. The sensor is located on the housing and its height can be adjusted in line with the control requirements for the oil level. The minimum level is ca. 35 mm from the centre of the lower fastening screw.

Request for a quote

Germany

Verified by Europages

▪ Automated emptying system for containers up to approx. 30 liters ▪ Volumetric conveying progressive cavity pump based on the endless piston principle ▪ Pulsation-free and precise emptying and material supply to 1C and 2C dispensing systems ▪ In redundant dosing systems applicable ▪ For medium to high viscosity materials ▪ For structure sensitive, filled, abrasive materials ▪ Application for cylindrical or slightly conical metal and plastic containers ▪ Housing for machine safety and protection against dirt contamination ▪ Automatic retraction and venting the container as well as detection of media surface ▪ 4“-Touch panel with function keys for comfortable setting and parametrization of the system ▪ Externally controllable via Profinet interface ▪ Continuous determination of the position of the follower plate and level monitoring ▪ Adjustable pressure reduction for longer pauses

Request for a quote

Germany

Verified by Europages

The NR 260 is a capacitive level sensor for monitoring liquids. It is designed for use in fuel cells. The material is also suited to applications in the chemical industry for monitoring aggressive media. The functions for MIN or MAX monitoring as well as other properties (output signal LSS or HSS, response delay etc.) are factory pre-set. The Main Features of the NR 260 are high medium resistance of materials enamel, Hastelloy C4 2.4610 and stainless steel 1.4571 high protection class IP67 with connector short-circuit proof switching output 1 A, high side or low side switch MAX sensor or MIN sensor switch point factory pre-set for the following media: de-ionised water (conductivity < 4,2 μS/cm): 28 mm ± 2 mm tap water (conductivity ≈ 300 μS/cm): 22 mm ± 2 mm other media upon request; switch point adjustment via programmable interface on request

Request for a quote

Germany

Verified by Europages

BEDIA intelligent tank sensor ITS 65 is used to monitor the filling levels of oils of any kind. The sensor is able to automatically recognize and what kind of oil (hydaulic oil, engine oil etc.) is present and calibrates itself to it. The capacitative measurement principle permits measurement of levels without mechanically moving parts. This considerably increases stability and operating safety. Mechanics The new tank sensor ITS 65 is characterized by a particularly stable, but light mechanical system specially designed for “Heavy Duty Applications”. The mounting flange and measurement tube are constructed from die cast aluminium. This construction permits the insertion of tank sensors up to 1200 mm in length, without additional support on the tank floor. Analogue Output The analogue output is available as an voltage output with a range from 0 V to 10 V or as an PWM output.

Request for a quote

Germany

Verified by Europages

BEDIA intelligent tank sensor ITS 60 is used to monitor the filling levels of Diesel fuels. The sensor is able to automatically recognize what kind of Diesel fuel (Bio-Diesel, Summer-/Winter-Diesel etc.) is present and calibrates itself to it. The capacitative measurement principle permits measurement of levels without mechanically moving parts. This considerably increases stability and operating safety. Mechanics The new tank sensor ITS 60 is characterized by a particularly stable, but light mechanical system specially designed for “Heavy Duty Applications”. The mounting flange and measurement tube are constructed from die cast aluminium. This construction permits the insertion of tank sensors up to 1200 mm in length, without additional support on the tank floor. The flange hole distribution is compatible with commercially used tank sensors. This means that this system can be used without expensive conversions.

Request for a quote

Turkey

Verified by Europages

"The M-PDU series is designed to suit the operational. Requirements of next-generation data centerts. M-PDU is a Sustainable, Upgradeable and Maintainable (SUM) PDU system which can be re-configured or upgraded hot without affecting the operation of data center. M-MPDU is offered in four different feature levels; Monitored PDU (MA) Per Port Monitored PDU (MB) Switched PDU (MC) Per Port Monitored & Switched PDU (MD) "

Request for a quote

Switzerland

Verified by Europages

With up to 8 MPP trackers and a maximum efficiency of 98.9%, our inverters deliver high performance. Benefit from a wide output voltage range, zero export application, and rapid response time. Our inverters offer additional features such as reactive power compensation, module-level monitoring, and IP67 protection. Enjoy reliable and efficient power conversion with JASC inverters.

Request for a quote

France

Verified by Europages

Portable energy station 230 VAC outputs Outputs 20.3 to 29.4VDC direct from battery, stabilised output possible (30W) Input: 10-40 VDC 60W, 96-230 VAC 50 Hz via mains adapter, 4-pin WEIPU connector Li-ion battery (battery pack guaranteed for 2 years or 600 cycles) Protection class: IP 65, IK08 Quick and easy to recharge: 230 VAC mains, cigarette-lighter socket, solar panel (optional) Customisation options 30W stabilised DC output (example: 12V) USB connection for battery level monitoring or small device recharging (e.g. smartphone)

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

—Capacitive proximity switches for the detection of non-metallic and metallic objects —Smooth plastic sleeve —Diameter 20 mm, 34 mm —for counting, position queries of parts or products, for example in furnace technology, chemical industry or plastics processing — with additional PTFE sleeve suitable for level monitoring in tanks

Request for a quote

Germany

Verified by Europages

EGE microwave filling level monitors monitor the filling level of fluids, powders and granulate with a low DK value and are particularly resistant to adhesion. The MFC sensors are also suited for separation layer detection. The sensitivity is adjustable. The sensors are based on a special variant of microwave frequency shift technology. EGE supplies the sensors in varying lengths up to 1000 mm. The stainless steel and PTFE sensor tip is suited for use in aggressive media.

Request for a quote

Germany

Verified by Europages

Robust and reliable level monitoring for fluids and bulk materials in cylindrical design with thread. The sensors are suited for installation using mounting plates and nuts or adapters in the tank wall. The sensors are based on the proven capacitive principle. The medium to be detected functions as dielectric. The medium in touch with the sensor generates a capacity change. This is converted into a switching signal or an analogue 4...20 mA output signal. EGE filling level sensors in cylindrical design are designed for rough industrial environments with PTFE housing for use in aggressive media. Also available with robust stainless steel thread.

Request for a quote

Germany

Verified by Europages

Capacitive filling level monitors for operation at medium temperatures of up to 230° C. With PTFE or PEEK housing and stainless steel thread for use in aggressive media. The sensors are based on the proven capacitive principle. The medium to be detected functions as dielectric. The medium in touch with the sensor generates a capacity change. This is converted into a switching signal or an analogue 4...20 mA output signal. This applies both to conductive and on-conductive media. With their small design the sensors of this series are well suited for installation in tight spaces. Upon request we supply the sensors with FDA certificate.

Request for a quote

Germany

Verified by Europages

EGE microwave level sensors monitor the filling level of fluids, powders and granulate with a low DK value and are particularly resistant to adhesion. The MFC sensors are also suited for separation layer detection. The sensitivity is adjustable. The sensors are based on a special variant of microwave frequency shift technology. EGE supplies the sensors in varying lengths up to 1000 mm. The stainless steel and PTFE sensor tip is suited for use in aggressive media.

Request for a quote

Germany

Verified by Europages

The slimline probe LMK 306 with ceramic sensor has been especially designed for the continuous level measurement at confined space conditions. Permissible media are clean or slightly contaminated water and thin fluids. Different cable sheath materials are available in order to achieve maximum media compatibility. Features: — nominal pressure: 0 ... 6 mH2O up to 0 ... 200 mH2O — accuracy: 0.5 % FSO — diameter 17 mm — excellent long term stability — suitable for hydrostatic level measurement e.g. 3/4" pipes — excellent linearity Optional Features: — different cable materials — customer specific versions e.g. special pressure ranges Preferred areas of use: — level measurement at confined space conditions — ground water monitoring — depth or level measurement in wells — drinking water abstraction — level measurement in open and closed tanks

Request for a quote

United Kingdom

Verified by Europages

Our fuel level monitors help keep you warm with minimum effort. This highly accurate fuel level monitor is the world’s first battery driven, wireless radar monitor. Magnus Monitors provide accurate real-time information about the level of oil in your tank from your smart device (Android & iOS) and also allow us to remotely monitor the levels and schedule your fuel delivery to prevent you from running out.

Request for a quote

Germany

Reflexion level gauge type 410- PN16-40- with frontally welding ends Ø 20 x 2,6 operating pressurre max. 35 bar Use: This sightglasses suitable for visual inspection of liquid levels in the tank, they enable reliable monitoring of the level.

Request for a quote

Germany

Reflexion level gauge type 411- PN16-40- welding ends Ø 20 x 2,6 operating pressurre max. 35 bar Use: This sightglasses suitable for visual inspection of liquid levels in the tank, they enable reliable monitoring of the level.

Request for a quote

Germany

Force-of-gravity separators, which are used as pre-filters or for the separation of large quantities of dust and swarf. Cyclone separator Cyclones are force-of-gravity separators. The separation principle is based on centrifugal force, which is produced by the tangential injection of the raw air. Cyclones are used as pre-filters or for the separation of large quantities of dust and swarf. The degree of separation of a cyclone is not normally sufficient to meet the usual environmental protection requirements. The cyclone exhaust air must be post-filtered in most cases. Product description A cyclone essentially consists of three parts: the intake cylinder, the cone and the immersion tube. In the intake cylinder, the raw air is brought into a circular path by means of tangential injection. Due to the taper of the subsequent cone, the speed of rotation increases sharply, so that the particles are pressed by centrifugal force against the outer wall and decelerated by friction, causing them to drop out of the air stream and fall down. The cleaned air leaves the cone in an upward direction via the central immersion tube. Cyclones are usually welded sheet steel structures. Cellular wheel sluices or, in individual cases, double-gate sluices are used for the pressureless discharge of the material. In order to increase the cyclone effect, or the degree of separation, counter-spirals with a pipe connection can be placed on top of the immersion tube. Further options are, for example, wearing devices, explosion pressure relief devices, control flaps, level monitoring devices and manufacturing in stainless steel or galvanised sheet steel.

Request for a quote

China

The DJY and DJM series boiler drum electrode sensor is matched with our company’s UDZ double color digital display intelligent liquid level controller. It can be widely used in large and medium-sized boilers of power generation, dyeing and weaving, chemical industry and other industrial and mining enterprises. It can be used to monitor the water level of boiler drum, high-pressure heater, generator, evaporator, condenser, Start-up Separator of once through boiler, water tank of double water-cooled generator, and liquid level measurement of other conductive liquids. Screw Type Electrode Sensor This electrode sensor mainly used on boiler and to measure the boiler drum water level.

Request for a quote

Germany

P-Sense transducers for pressure and temperature can be used both in air and in water or other fluids. Devices come with analog, digital or switching output and can be configured for absolute pressure or gauge pressure measurements. Potential fields of application are water level monitoring or fluid level measurements, e. g. in bodies of water, sewage treatment plants, storage tanks etc. The p-Sense320 probe can be fitted with an RS485 interface instead of an analog output which can optionally be connected to a computer using a RS232 adapter. Connection and data transfer to a PC/notebook can established with the Windows terminal.

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free