Belgium
Distributor
Belgium
Useful cooling output 1,500 W. The cooling unit may be attached to the enclosure in 3 positions (external, partial internal and full internal mounting). The energy-efficient wall-mounted cooling unit Blue e+ Outdoor can be used worldwide, thanks to its multi-voltage capability, and is suitable for use with Toptec project solutions, for example Average 75% energy savings thanks to speed-regulated components and heat pipe technology Longer service life of the components inside the enclosure and the cooling unit due to component-friendly cooling Intuitive operation due to touch display and intelligent interfaces SK Blue e+ cooling unit, wall-mounted, outdoor, 1.6 kW, 110 – 240 V, 1~, 380 – 480 V, 3~, 50 – 60 Hz, aluminium, WHD: 400 x 950 x 310 mm
Request for a quoteBelgium
Sheet steel section doors for the installation of climate control module types SK 3307.7XX to 3310.7XX. Sheet steel section doors for the installation of climate control module types SK 3307.7XX to 3310.7XX. SK modular climate control concept, Section doors, for TS8 WH: 600 x 1800 mm
Request for a quoteBelgium
Air/water heat exchanger in TS 8 baying system, useful cooling output 10 kW. Air/water heat exchangers in TS 8 baying system, to fit 600 or 800 mm deep and 2000 mm high TS 8 enclosures. Air outlet either with 5 kW on each side or 10 kW on one side only. Flexible water connection options on the top or bottom of the unit. SK Liquid Cooling Package, Air/water heat exchanger in TS 8 baying system, 9.5 kW, 230 V, 1~, 50/60 Hz, Water-carrying parts: copper/brass , WHD: 300 x 2000 x 600 mm
Request for a quoteBelgium
We can help boost the efficiency of your plant design with original CAD data for Rittal components, whichever CAD system you are using. We can help boost the efficiency of your plant design with original CAD data for Rittal components, whichever CAD system you are using. Benefits for users • All CAD data can be transferred into all common CAD systems thanks to the smart, native, 2D/3D multiCAD-compatible format. • The accurately detailed and validated drawings allow users to generate design drawings with maximum planning confidence, in a fraction of the time taken for conventional design, by simply remodelling. • Because the level of detail in CAD models is freely selectable, thy may be represented in a greatly simplified format, thus boosting users’ performance significantly.
Request for a quoteThroughout the world, Rittal is a leading global provider of solutions for industrial enclosures, power distribution, climate control and IT infrastructure, as well as software and services. The Rittal Automation Systems offers automation systems for switchgear construction. Rittal global solutions can be applied in all industrial sectors, machinery and facility construction, as well as in the information technologies and telecommunications sector. Rittal works from 18 production sites and 80 subsidiaries.
Germany
the economical alternative Replacement for STRATE 1DF2 and 2DF2 pump controllers suitable for connection to all STRATE fill level recording systems: contact-based or contactless the 2DF2 plus also handles dual level measurement: Sensor/pilot tube and sensor/contactor for outstanding operational reliability the current level and operating hours are always shown on the display
Request for a quoteGermany
2DFmaster AWAcontrol control system for STRATE sewage pumping stations with two pumps each and an installed overall motor rating of 0.75 kW to 75 kW each. Particularly suitable for building services engineering and municipal applications (twin systems), offers outstanding ease of use and functionality of the AWAmaster technology also for pumping capacities over 4 kW. LCD plain text display Thermal and electrical motor monitoring Manual – 0 – Automatic functions Pump switch-off through switch-off point with run-on time Acknowledgement button Electronic monitoring of the motor current Forced switch-on, switchover and alternation of pumps Internal acoustic alarm Collective fault message potential-free and potential-bound Backwater alarm potential-free All settings and fault messages retained after power failure Operating hours counter High resistance to interference Simple operation Level recorded either by internal pressure transducer, external 4 – 20 mA probe or float switch
Request for a quoteGermany
Compact control systems with micro-processor technology for controlling STRATE sewage pumping stations with two pumps each and an installed motor rating of up to 5,5 kW per pump. Particularly suitable for building services engineering (twin systems) and do not require a separate control cabinet. Compact control system AWAmaster 2 in plastic housing Ready for connection with 1.5 m cable and CEE plug 16 A, 5-pole Parallel operation of both pumps to cope with increased sewage volume (e.g. during heavy rain) LCD plain text display Thermal and electrical monitoring of the motors Manual – 0 – Automatic functions Pump switch-off through switch-off point with run-on time Acknowledgement button Electronic monitoring of the motor current Forced switch-on, switchover and alternation of pumps Variable graduated start-up (switch-on delay) Internal acoustic alarm Collective fault message potential-free and potential-bound Backwater alarm potential-free
Request for a quoteGermany
The compact control system with micro-processor technology for controlling STRATE sewage pumping stations with one pump and an installed motor rating of up to 5,5 kW. Particularly suitable for building services engineering (single systems) and do not require a separate control cabinet. Compact control system AWAmaster 1 in plastic housing Ready for connection with 1.5 m cable and CEE plug 16 A, 5-pole LCD plain text display Thermal and electrical monitoring of the motor Manual – 0 – Automatic function Pump switch-off through time or switch-off point Acknowledgement button Operating hours counter Ammeter Electronic monitoring of the motor current Forced pump switch-on Variable graduated start-up (switch-on delay) Internal acoustic alarm Collective fault message potential-free and potential-bound Flood alarm potential-free All settings and fault messages retained after power failure (battery back-up not required) Reserve inputs for float switch, telecontrol module
Request for a quoteCreate one request and get multiple quotes form verified suppliers.