• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • calibration gas

Results for

Calibration gas - Import export

United Kingdom

Our non-refillable calibration gas canisters are designed specifically for the calibration and bump testing of single and multigas analysers. We offer a wide range of gas mixtures, with the option of multigas mixtures too. Our 34L, 58L, and 110L gas canisters provide the ideal solution for functional testing of gas detection and analytical equipment and being lightweight and compact means they can be easily carried in the workshop or on site. All of the canisters in our range are disposable and can be recycled when empty by using our handy recycling tool.

Request for a quote

France

Verified by Europages

The MGC101 system automatically performs zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, 03, hydrocarbons and other gases.

Request for a quote

Germany

Verified by Europages

The Atlas HVFAA Horizontal Vertical Flame Chamber provides the most accurate means for determining the flammability of aircraft cabin and cargo compartment materials, liners and waste stowage compartment materials, and electric wire. The large volume chamber prevents oxygen depletion during tests. Three digital timers with remote control make specimen event timing precise and convenient. To ensure accurate and repeatable tests, an optional burner flame temperature verification kit is available. The HVFAA is the optimal instrument for conducting repeatable FAA flammability tests. Designed to be used for testing in accordance with FAA's Aircraft Material Fire Test Handbook DOT/ FAA/AR-00/12, Chapters 1.0 - 4.0 (FAR 25.853, 25.855, 25.1359) Draft-free large volume (>0.5m 3) flame chamber Vertical, Horizontal, 45 Degree and 60 Degree Wire Test Packages Sliding hand ports for chamber access Regulated gas control system Calibrated gas flow meter with precision needle valve adjustment ASTM D5025 Bunsen burner with remote positioning Stopwatch plus three handset operated digital timers Tempered glass sliding window Interior inspection light Flame height gauge High temperature exhaust blower with variable speed control ASTM D5207 flame confirmation kit

United Kingdom

Verified by Europages

DUAL GAS LEAK DETECTOR HX-490S Dual Gas is the most advanced sniffing Helium/Hydrogen leak detector designed specifically for industrial environments. The HX-490S Dual Gas utilizes industrial-grade mass spectrometer to achieve the highest sensitivity, fastest response-time, and smallest footprint. With a touch of a button, this dual gas unit can detect either Helium or Hydrogen tracer gases, while using a single built-in dual purpose calibrated gas leak. Fastest response time in the industry (less than 0.5 seconds) Tracer gas background suppression Sensitivity to 5 x 10-8 atm cc/sec Less than 3 minutes total start-up time Fully automatic calibration sequence with built-in dual purpose gas leak User selectable between helium and hydrogen sniffer Front panel key lock-out Sealed membrane keypad Fully interactive system diagnostics with multilingual displays High output (110dB) adjustable audio alarm Flow units (cc/sec, oz/yr, Pa m3/s) Helium or hydrogen sniffing test

Request for a quote

Germany

Over the last few years, we at EP-E have designed and introduced a series of primary standards for gases, designed for use in calibration laboratories. As a technology partner of the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, our solutions are based on the highest standards. The EP gas bell plungers generate a volume flow which is traceable to the SI units length and time. The pistons are driven by a stepper motor via a spindle. In the initial state one piston is fully retracted and the other fully extended. The volume flow can be set with high precision via the piston cross section and the travel speed. At the end of the calibration process, both pistons are in the opposite position to the initial position. The calibration device is preferably operated with air, which can be supplied with up to 6 bar. The EP gas bell pistons convince by highest measuring accuracy up to 0.15% (k=2).

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

The test bench is designed for calibration with critically operated nozzles of domestic gas meters or others such as diaphragm gas meters, ultrasonic meters, thermoelectric gas meters. The test bench is specially designed for the calibration of domestic gas meters (bellows gas meters, ultrasonic meters, thermoelectric gas meters). The test bench is modular - 1x6 to 4x6 clamping positions for the gas meters can be combined. Due to the modular design 1 to 12 gas meters can be tested simultaneously. In parallel, up to twelve additional test pieces can be adapted, run in and leak tested. A magazine consisting of three critical nozzles is used as flow transmitter. Optionally, a nozzle drum with nine combinable nozzles can be used. This allows the generation of up to 512 different flow points with highest accuracy.

Request for a quote

Germany

The high-precision calibration laboratory is accredited according to DIN EN ISO/IEC 17025 for flow calibration of flowing gases. The EP calibration laboratory is accredited by the DAkkS according to DIN EN ISO/IEC 17025:2005 for calibrations of gases in-house and on-site under the procedure number D-K-21444-01-00. We offer calibrations for gas flow measurement as well as temperature, humidity and pressure measurements. In addition, we calibrate all measured variables of the test bench directly at your site. Our experienced technicians also check the harmonious interaction of all sensors, so that the entire system is perfectly tuned. The opening of our new calibration laboratory in Asia enables us to offer you even better service internationally.

Request for a quote

Russia

While introducing a new line of gas analysis equipment to the market, we offer a fundamentally new concept of gas analysis systems based on replaceable modular gas analyzers GAOS SENSON-SM-9001. Advantages: - Radically reduced downtime required for calibration and repair - Reduced spare equipment costs - Increase the offline resource of remote objects - Extra-low delivery times New concept: - simplifies the replacement of gas analyzers for calibration and in the event of a malfunction – in the case of GAOS SENSON it is as simple as changing a light bulb, no need to dismantle/change the entire device. That is, it is enough to change a lightbulb, not a chandelier; - it dramatically reduces the stock of replacement systems in volume and cost – only the GAOS SENSON-SM-9001 modules are needed (supply of light bulbs, not chandeliers); - requirements for the qualification of staff (there is only one requirement – accuracy) are reduced.

Request for a quote

France

Detects Explosive and Toxic Gas, or Oxygen Non-Intrusive Calibration Smart Infrared Gas Sensors HART Communication Protocol (NEW) MODBUS Communication Programmable Relays Dual Gas Sensing (*) versions with local visible alarm are to be installed in ordinary locations only

Request for a quote

France

The PS200 Series combines quality, ruggedness and advanced technology in a user friendly, portable gas monitor. It is compact, lightweight, water resistant, extremely robust, and is certified to multiple international and regional standards. The PS200 can measure any combination of LEL, O2, CO and H2S making it suitable for a wide range of personal monitoring and confined space applications. PS200 Auto Bump/Calibration Station The multifunctional Auto Bump/Calibration station provides simple but intelligent testing and calibration of the PS200 portable gas detector. Easy to use, with a durable, user friendly design, this automated test station offers high performance from a PC or stand-alone unit. The Auto Bump/Calibration station dramatically improves compliance record-keeping, efficiency, and accuracy. Once the PS200 is placed in the dock it can be tested, calibrated, and charged. Extremely cost effective, the station requires no testing and minimal effort by users.

Request for a quote

Germany

10 litres calibration gas (100 ppm H 2 in nitrogen) for all FAN H 2 breath test devices. Compressed in an 1–litre aluminium can, at least 12 calibrations can be readily achieved.

Request for a quote

Germany

Control valve and Flow indicator for use with calibration gas cylinder. Flow meter markings are nominally 0.5 & 1.0 litres/min.

Request for a quote