Results for
ALTMANN GRAPHISCHE MASCHINEN GMBH
Germany
age 2009 external condensator with double blower Delivery time: immediately from stock Ref: TE240038A Please ask for price. We ship and install worldwide!
Request for a quoteMITA COOLING TECHNOLOGIES
Italy
Compact, efficient and easily accessible: MCE industrial condenser ensures refrigeration operators all the operating standards of its own technology class. The typical MITA evaporative coolers’ durability over time is a plus. MCE-EC version available with electronically controlled fans.
Request for a quoteMITA COOLING TECHNOLOGIES
Italy
Ideal for water saving maintaining a high efficiency. All operations are managed by PLC with the possibility of remote management in “Industry 4.0” mode. Both HVAC and refrigeration sectors can be served.
Request for a quoteRIMA HEATING SYSTEMS
Turkey
Corrosion resistant, light Aluminium heat exchanger Efficiency upto %107 Six different capacities for Ongas 300 (70, 95,115,125,155,190 kW) Eight different capacities for Ongas 600 (220,305,380,455,530,605,680,850 kW) Cascade system with 16 boilers
Request for a quoteBÜCHI AG
Switzerland
Heat exchangers are mainly used in vacuum distillation systems for cooling and condensation in the absorption and rectification processes in chemical plants. Glass heat exchangers enable visual process control during scale-up and production and processing of multiple (acidic) chemical substances. We offer glass spiral type and shell & tube type heat exchangers. These are often operated in combination with a secondary condenser for additional vapor condensation. The glass spiral heat exchangers can be operated in parallel to form large heat exchange areas for higher condensation performances and larger reactors systems in pilot plants. They feature easy cleaning and operation of cooling media at up to 3 bar pressure.
Request for a quoteELECTRONICON KONDENSATOREN GMBH
Germany
The winding elements in our MKP(D) capacitors are surrounded by poison-free vegetable oil. Like our premium ranges of MKPg and MKP, the MKP(D) combines the best possible technical features with eco-friendliness and operational safety, using special metallizing patterns, our SINECUT slitting technology and optimized winding geometries. Besides excellent ratio of capacitance to volume, our MKP(D) capacitors distinguish themselves by high AC-voltage load capacity and suitability for high rms and surge currents. Our MKP(D) are available as single and three-phase capacitors and well-suited for all conventional applications in power factor correction. They have a self-healing dielectric and are provided with an irreversible overpressure disconnector (break-action mechanism, " BAM "). Connection is made through convenient standard 6.3mm tab connectors. Technical layout, testing and application accord to IEC60831, UL810 and CSA 22.2.
Request for a quoteELECTRONICON KONDENSATOREN GMBH
Germany
With our long year know how and first-class production facilities, we are manufacturing capacitors in two basic technologies: MKP and MKPg™. In MKP capacitors, the winding elements are surrounded by poison-free vegetable oil, in MKPg™, capacitors, they are immersed by neutral insulation gas. When designing our product ranges, we focussed on the best possible technical features combined with eco-friendliness and operational safety, using special metallizing patterns, our SINECUT slitting technology and optimized winding geometries. Besides excellent ratio of capacitance to volume, our power capacitors distinguish themselves by high AC-voltage load capacity and outstanding suitability for high rms and surge currents. Unlike some of our competitors who proudly quote fantasy ratings, we have really tested our capacitors to their rated values, allowing for sufficient reserves and guaranteeing flawless operation within the specifications.
Request for a quoteELECTRONICON KONDENSATOREN GMBH
Germany
The custom-tailored capacitors of our E70 series are mainly applied for power factor correction or as resonance capacitors in induction furnaces that are operated at mains frequency (50/60Hz). The E70 are made alternatively in two designs: Inside the steel case, there is a large number of individual self-healing capacitors, each one of them protected by its own break-action mechanism. In the event of a failure, the affected element is disconnected separately while the capacitor as a whole continues to function with slightly decreased total capacitance. Windings assembled inside a hermetically sealed metal case, filled with solid resin, and protected by a pressure sensor similar to the capacitors of our ranges E56/E59.
Request for a quoteELECTRONICON KONDENSATOREN GMBH
Germany
The capacitors of our SR17™ series were developed especially for the maintenance of older traction converters manufactured in the 1970s?1990s. By consequent development of our well-proven MKP-technologies, we managed to place self-healing DC-capacitors with very high energy density and stability of capacitance into can dimensions smaller than, or identical to, those of the traditional MP-capacitors (SIEMENS/EPCOS codes B25353), which makes them ideal drop-in replacements for maintenance and retrofit programmes. Moreover, the low-loss polypropylene dielectric permits a far higher AC ripple load than with the conventional MP-capacitors. Our SR17™ are housed in a hermetical stainless steel cylinder. As opposed to the oil-filled MP-models, these are filled with an eco-friendly solid resin which does not only make them safe against leakage of liquids but also insensitive to the shocks and vibrations common in traction applications. The same applies to their robust plastic insulators.
Request for a quoteELECTRONICON KONDENSATOREN GMBH
Germany
Using selected low-loss, self-healing polypropylene films and sophisticated manufacturing techniques such as high-vacuum drying and special coating patterns, the best of ELECTRONICON™s design expertise and highest care in manufacturing have been spent to prepare these capacitors for your most demanding applications, and toughest ambient conditions. Our long-life MKP UHDTM contain three delta-switched capacitor elements of short height and large diameter. The optimized combination of winding length, film size, and winding geometry substantially reduces inherent power losses and allows us to achieve highest surge and rms current ratings as well as an overvoltage strength and switching stability which before would have been known only of impregnated paper capacitors. An MKP UHD™ handles up to 250% of its rated current and current surges of 400 x IN. The permitted operating temperatures range from -40°C up to 70°C maximum temperature (average over 24 hours: 60°C).
Request for a quoteELECTRONICON KONDENSATOREN GMBH
Germany
Who said it has to look like a surge capacitor? They look different, and as a matter of fact, they are. Surge protection capacitors are designed to protect high voltage motors and transformers from events with high transient overvoltages (e.g. lightning or switching surges). Keeping with our tradition of completely dry products, we have designed the first MV Surge Capacitor in self-healing technology: DSCTM In combination with the PD-free layout, the self-healing dielectric provides for extremely long operating life and highest operational safety. Unlike traditional oil-filled ALLFILM-capacitors which are bound to fail as soon as overvoltage or other stress factors have provoked a dielectric breakdown, the self-healing dielectric of DSCTM insulates the breakdown spot immediately and continues operation as usual.
Request for a quoteSONKAR REFRIGERATION
Turkey
EWEREST3000 85 kw to 109 kw FAN:6x450 to 6x500
Request for a quoteCDS GROUP MARINE & INDUSTRIAL
United Kingdom
Carrier Condenser Coil to NLNG (Nigeria Liquefied Natural Gas) specifications and complete with BLYGOLD protection.
Request for a quoteCDS GROUP MARINE & INDUSTRIAL
United Kingdom
Carrier Condenser Coil to NLNG (Nigeria Liquefied Natural Gas) specifications and complete with BLYGOLD protection.
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
ETERIKA LTD
Bulgaria
Almost all hair conditioners come into contact only with the visible part of the hair, above its tube. Hair thickening conditioner - original cosmetics of the Polish inventor, doctor of chemistry Krzysztof Słonia - thanks to the presence of active diosmin. It combines a high concentration of diosmin, which causes increased blood flow through the blood vessels of the bulb, leading to more nutrients used by the body for hair growth.
Request for a quoteBIMKO ELEKTRIK
Turkey
Compatible Brands: WHIRLPOOL - BAUKNECHT - INDESIT Original Codes: 481010716911
Request for a quoteBIMKO ELEKTRIK
Turkey
Compatible Brands: WHIRLPOOL - BAUKNECHT - INDESIT Original Codes: 481010354757
Request for a quoteBIMKO ELEKTRIK
Turkey
Compatible Brands: SMEG - BEKO Original Codes: 782372152
Request for a quoteBIMKO ELEKTRIK
Turkey
Compatible Brands: CANDY - HOOVER Original Codes: 40006731
Request for a quoteBIMKO ELEKTRIK
Turkey
Compatible Brands: MIELE Original Codes: 7070070
Request for a quoteBIMKO ELEKTRIK
Turkey
Compatible Brands: MIELE Original Codes: 6057930
Request for a quoteBIMKO ELEKTRIK
Turkey
Compatible Brands: MIELE Original Codes: 9164761
Request for a quoteBIMKO ELEKTRIK
Turkey
Compatible Brands: MIELE Original Codes: 9499230
Request for a quoteBEKO TECHNOLOGIES GMBH
Germany
The generation of compressed air is always connected with the formation of condensate. In most cases, this condensate contains oil, is contaminated with dirt particles and spreads out in the entire compressed-air system. A system problem which can result in damage and additional costs. The BEKOMAT drains condensate in the compressed-air system in an electronically level-controlled manner. More than 3,000,000 installations worldwide make it the industrial standard for reliable and cost-effective condensate drainage.
Request for a quoteFRIEDR. FREEK GMBH
Germany
The Nomex heating band is an inexpensive solution for applications where a flexible heating element with low power (max. 1 W/cm²) and for max. temperatures of 150 °C is required. A well-established application is it's utilization as standstill heater to prevent condensation and frost damage when motors stand idle in cold environments. Standstill heaters reliably keep motors or electrical machines above the dew point and ensure safe operation even in harsh ambient conditions. The minimum width of the heating element is 12 mm with a maximum length of 1000 mm, bending radii of at least 15 mm are possible.
Request for a quoteSTEFANI SPA
Italy
ZONDA C is the Vtype condenser allow heat exchange designed for environments where dimensional restraints are important or visibility on the roofs is limited.
Request for a quoteResults for
Condensers - Import exportNumber of results
191 ProductsCountries
Category