• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • fire dampers

Results for

Fire dampers - Import export

Poland

Verified by Europages

The FDA12 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification f construction products and building elements). The fire resistance was tested as per PNEN 136622001P (Fire resistance tests for service installations Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA12 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN100, DN125, DN160, DN200, DN250, and DN315. All fire dampers have a pull spring control gear and a fusible thermal trip (in FDA12T) or a returnspring actuator coupled with a thermal trip (in FDA12M).

Request for a quote

Poland

Verified by Europages

The FDA12 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification f construction products and building elements). The fire resistance was tested as per PNEN 136622001P (Fire resistance tests for service installations Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA12 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN100, DN125, DN160, DN200, DN250, and DN315. All fire dampers have a pull spring control gear and a fusible thermal trip (in FDA12T) or a returnspring actuator coupled with a thermal trip (in FDA12M).

Request for a quote

Poland

Verified by Europages

The FDA212 square fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal sizes 160x160 – 1000x500 mm. All fire dampers have a torsion spring trip (in FDA212T) or a returnspring actuator coupled with a thermal trip (in FDA212M).

Request for a quote

Poland

Verified by Europages

The FDA212 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN200, DN224, DN250, DN280, DN300, DN315, DN355, DN400, DN450, DN500, DN560, DN600, DN630.

Request for a quote

Poland

Verified by Europages

The FDA212 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN200, DN224, DN250, DN280, DN300, DN315, DN355, DN400, DN450, DN500, DN560, DN600, DN630. All fire dampers have a torsion spring trip (in FDA212T) or a returnspring actuator coupled with a thermal trip (in FDA212M).

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Poland

Verified by Europages

The fire dampers are manufactured in the following nominal sizes DN100, DN125, DN160, DN200. The fire dampers are equipped with a thermal fuse mechanism ensuring the damper switch to the safe position in case of reaching an ambient temperature equal to or higher than 72°C. The fire dampers allow using limit switches signalling closed position of the damper blade (1 limit switch) or blades (in case of using 2 limit switches). The casing is made from galvanised steel sheet; the fire damper blade is made from a silicate cement board.

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - Intumescent gas, smoke and flame tight seal in case of fire - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards - Quick and easy installation The 60-minute ceiling fire dampers are designed for installation in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against fire progression from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms. The safety catching arms ensure that the lid is intercepted every time the hatch is opened. The lid is easy to remove and replace.

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1 : +A1 : 2018 Fire dampers EI 30 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 30. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1 : +A1 : 2018 Fire dampers EI 90 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 90. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.

Request for a quote

France

Verified by Europages

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.

Request for a quote

Luxembourg

Verified by Europages

All types of fireproof doors. Fireproof shutters. Products for shielding of all types of technical equipment (electrical cables, insulated and non-insulated sanitary heating pipes, PP/PE pipes, fireproof dampers). Fire-protection products for ventilation ducts and cable trays. Fire-protection products to protect my load-bearing structures (fireproof plates, paint, flocking, etc.) Fire-protection products for fireproof compartmentalisation: fireproof partitions and ceilings. Products for decorating elevator cars made of materials that are difficult to ignite. Fireproof valves, grilles, sleeves, seals and hatches. Fireproof compartmentalisation for protecting people and property Fireproof compartmentalisation, the means used Fireproof compartmentalisation is done by means of: Fireproof doors, curtains, shutters Fireproof partitions Fireproof ceilings Fireproof shielding Contact us for a quote or informations.

Request for a quote

Poland

Verified by Europages

The FDABURML coupling module is a combination of an air valve and a fire damper, coupled with a single housing. This is an alternative to typeical fire valves. The main advantages of the FDABURML are better fire rating and a smaller size with more product configurations and application options. The main component of the coupling module is the CFDM fire damper. The fire damper is available in Ø 100, 125, 160, and 200 mm. The wing blade of the damper provides a very low resistance to the air flow. The fire damper can be ordered with one or two optional limit switches to feed back the actual blade position. The FDABURML coupling modules match the most popular versions of air supply or exhaust valves which can be replaced with one another, even with the coupling module installed in a partition or already in use. The entire coupling module is compact. As a result, the air valves with the mounting frames cannot exceed 50 mm in height.

Request for a quote

Belgium

Verified by Europages

Isolation Unit, 2-piece, for positive or negative room pressure This Isolation Unit is made for installation on walls or windows. Pressure differences up to 20 Pascal are easily generated. Negative pressure is obtained when the filter unit is placed inside the room, and the ventilator unit is placed outside the room. (infectious patients) Positive pressure is obtained when the ventilator unit is placed inside the room and the filter unit is placed outside the room. (immune-compromised patients). Both parts are connected by a tube – through the wall – which contains an air back-pressure flap (standard) and fire damper (optional). Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured. – Automatic differential pressure regulation – Automatic pressure loss alert – Filter detection by ID code (filter condition) – Complies with CDC guidelines (Centres for Disease Control and Prevention)

Request for a quote

United States

1. Our cleanroom cleanliness level is high, meeting the requirements of GMP and other pharmaceutical standard; 2. Able to realize BMS automatic control; 3. Modular design, fast installation; 4. Construction material are CE certified; 5. High degree of safety, equipped with safety doors and fire dampers; 6. From A-Z, one-stop service from design to construction verification; 7. Can accurately control the temperature, humidity, pressure difference, the number of dust particles and planktonic bacteria; 8. The brand of HVAC can be specified by customer; 9. Able to send workers abroad for installation; 10. We have a strong design team, able to design according to customers' different needs.

Request for a quote